Correcting Diacetyl Concentrations from Air Samples Collected with NIOSH Method 2557

, , , , , , , , & show all
Pages 59-70 | Published online: 10 Jan 2011
 

Abstract

Diacetyl (2,3-butanedione), a diketone chemical used to impart a buttery taste in many flavoring mixtures, has been associated with bronchiolitis obliterans in several industrial settings. For workplace evaluations in 2000–2006, National Institute for Occupational Safety and Health (NIOSH) investigators used NIOSH Method 2557, a sampling and analytical method for airborne diacetyl utilizing carbon molecular sieve sorbent tubes. The method was subsequently suspected to progressively underestimate diacetyl concentrations with increasing sampling site humidity. Since underestimation of worker exposure may lead to overestimation of respiratory health risk in quantitative exposure-effect analyses, correction of the diacetyl concentrations previously reported with Method 2557 is essential. We studied the effects of humidity and sample storage duration on recovery of diacetyl from experimental air samples taken from a dynamically generated controlled test atmosphere that allowed control of diacetyl concentration, temperature, relative humidity, sampling duration, and sampling flow rate. Samples were analyzed with Method 2557, and results were compared with theoretical test atmosphere diacetyl concentration. After fitting nonlinear models to the experimental data, we found that absolute humidity, diacetyl concentration, and days of sample storage prior to extraction affected diacetyl recovery as did sampling flow rate to a much smaller extent. We derived a mathematical correction procedure to more accurately estimate historical workplace diacetyl concentration based on laboratory-reported concentrations of diacetyl using Method 2557, and sample site temperature and relative humidity (to calculate absolute humidity), as well as days of sample storage prior to extraction in the laboratory. With this correction procedure, quantitative risk assessment for diacetyl can proceed using corrected exposure levels for air samples previously collected and analyzed using NIOSH Method 2557 for airborne diacetyl.

Acknowledgments

The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health or Occupational Safety and Health Administration.

Notes

A Number of samples used in equation development analyses.

B Nine each of the 0.5 and 25 ppm samples and 18 of the 5.0 ppm samples were used in both humidity and storage stability analyses.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.