Evaluation of Cut-Off Saw Exposure Control Methods for Respirable Dust and Crystalline Silica in Roadway Construction

, , &
Pages 157-165 | Published online: 06 Mar 2012
 

Abstract

Dust reduction equipment adapted for single-person operation was evaluated for gas-powered, commercially available cut-off saws during concrete curb cutting. Cutting was performed without dust control and with two individual exposure control methods: wet suppression and local exhaust ventilation (LEV). The wet suppression system comprised a two-nozzle spray system and a 13.3-L hand-pressurized water supply system with an optimum mean flow rate of 0.83 L/min for 16 min of cutting. The LEV system consisted of a spring-loaded guard, an 18.9-L collection bag, and a centrifugal fan with an estimated exhaust rate of 91 ft3/min. Task-based, personal filter samples were obtained for four saw operators during cutting durations of 4 to 16 min on five job sites. Seventeen filter samples were collected without dust control, 14 with wet suppression, and 12 with LEV, yielding a geometric mean respirable dust concentration of 16.4 mg/m3, 3.60 mg/m3, and 4.40 mg/m3, respectively. A dust reduction of 78.0% for wet suppression and 73.2% for LEV was observed vs. no dust control. A statistically significant difference (p < 0.001) was also revealed for wet suppression and LEV when compared with no dust control; however, a significant difference (p = 0.09) was not observed between wet suppression and LEV. Despite these significant dust reductions, workers are still projected to exceed the ACGIH 8-hr time-weighted average threshold limit value for quartz (0.025 mg/m3) in less than 1 hr of cutting for both dust control methods. Further research is still needed to improve dust reduction and portability of both control methods, but the current LEV system offers important advantages, including a drier, less slippery work area and year-round functionality in cold weather.

ACKNOWLEDGMENTS

This research study was supported by the participating contractor, E & B Paving, Inc., and by NIOSH and the Pilot Research Project Training Program of the University of Cincinnati Education and Research Center Grant #T42/OH008 432–04.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.