ABSTRACT

The “well-mixed room” two box models are often used to predict near and far field concentrations for a specific task, but are limited to scenarios where local exhaust controls are not used. In Part II of this series, new two box models are presented that permit local controls that either exhaust to the outside or return filtered air to the workspace. Additional models are presented that also allow for the recirculation of a filtered portion of the general ventilation flowrate. During the concentration increase phase the emission rate is assumed to be relatively constant. Both steady state and transient equations were developed for each scenario.

An additional factor, representing the fraction of time that the substance is being emitted during a task or set of tasks, was added to the standard and new steady state models. This simple modification permits the easy calculation of the average near and far field concentrations for cyclic and irregular emission patterns, provided the starting and ending concentrations are identical (e.g., zero or near zero) or the cumulative task time is long (e.g., two or more task cycles to a full shift, depending upon the number of room air changes per task). Additional variables are introduced with the new models, such as the efficiency of a local control to immediately capture freshly generated contaminant and the filtration efficiency whenever filtered exhaust is returned to the workspace.

Many of the model variables are knowable (e.g., room volume and ventilation rate). Others can be approximated using manufacturer specifications or published values (e.g., filtration efficiency). A structured procedure for calibrating a model to a work scenario is presented that can be applied to both continuous and cyclic processes. The “calibration” procedure generates estimates of all of the unknown model variables, including the generation rate and the effective near field flowrate (which takes into account potentially complex near field air currents as well as any thermal plumes created by a hot process).

View correction statement:
Corrigenda - Models for nearly every occasion: Part II - Two box models

Acknowledgments

This work was not funded by any organization. However, the authors thank Perry Logan (3M), Michael Murphy (3M), and Ron Pearson (Environmental Health & Safety, Inc.) for the discussions that led to the recognition that new one box and two box models might be a useful addition to our collective modeling toolbox.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.