A novel method on the optimization problem of energy conservation in public buildings

, ORCID Icon, &
Pages 3279-3296 | Received 20 Jul 2022, Accepted 27 Jan 2023, Published online: 29 Mar 2023
 

ABSTRACT

In recent years, the problem of energy consumption has received considerable attention. Among them, the proportion of energy consumption in public buildings accounts for a substantial part, and there is a large space for energy saving in this field. Practically, the major limiting factor for energy consumption optimization is indoor environment comfort degree. As such, a trade-off problem between energy conservation and indoor environment must be resolved. In this paper, an office in a public building is chosen as the experimental object, with 2520 real observations collected for two months, a series of intelligence based techniques are combined and applied to deal with this optimization problem. First, Partial Rank Correlation Coefficient (PRCC) was employed to perform correlation analysis for a set of candidate variables, such that the computational time of subsequent model training is reduced by 8.32 seconds as compared to the case where no PRCC is in use. Following this, Genetic Algorithm (GA)-based Levenberg-Marquardt algorithm (LM) are applied collectively to optimize the conventional Back Propagation (BP) neural network, and results suggest that there was a marked improvement in neural model performance, on one hand the epoch number for convergence drops from 72 to 13, on the other hand the mean squared error for test set is reduced by 7.46e-4 (from 9.93e-4 to 2.47e-4). Finally, pigeon-inspired Optimization (PIO) algorithm is employed to address the formulated optimization problem and the optimal value for Predicted Mean Vote (PMV) and Indoor Air Quality (IAQ) are −0.4775 and 0.007826, respectively. To verify the validity of our results that derived by the proposed approach, corresponding parameters are applied in a practical scenario. The experimental result indicates that the energy efficiency is improved by around 18.6% compared to that yielded before optimization is performed, which demonstrates the applicability and effectiveness of the proposed method.

Nomenclature

NThe total number of indoor gas pollutants of interest

Hi Highest concentration of the contaminant

Lo Lowest concentration of the contaminant

Cp Mass concentration value of pollutant index P

BPHi High value of contaminant concentration limit close to Cp

BPLo Low value of contaminant concentration limit close to Cp

IIAQIHi The indoor air quality index corresponding to BPHi

IIAQILo The indoor air quality index corresponding to BPLo

Tcl Clothing surface temperature ( oC); Tz Air temperature( oC)

pa Water vapor partial pressure (pa); hc Convective heat transfer coefficient (W/m2K)

fcl Clothing surface area factor; M Metabolic rate (W/m2)

W excreted work (/m2); Icl Clothing index; va Air velocity (m/s)

Trm Mean radiant temperature ( oC); RH Relative humidity

wZ Humidity of the air; wsat Saturation humidity of the air

Disclosure statement

No potential conflict of interest was reported by the authors.

Additional information

Funding

The work was supported by the National Natural Science Foundation of China [61873006]; Beijing Natural Science Foundation [4204087]

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.