ABSTRACT

Every residential refrigerator employs a Vapor Compression Refrigeration (VCR) technology. The performance of a VCR system is mostly determined by the input power and refrigeration effect. In present study, effects of varying concentrations of TiO2-SiO2/MO hybrid nano-lubricant (0.1, 0.2, 0.3, and 0.4 g/L), and mass charge of refrigerant R600a (80, 100, and 120 g) investigated by the authors. The performance parameters of the VCR test rig optimized at 0.2 g/L of hybrid nano-lubricant concentration using 100 g mass charge of R600a refrigerant. At this optimum condition, the percentage increase in coefficient of performance was 37.83% compared to the pure lubricant using 80 g mass charge of R600a refrigerant. The percentage reduction in input power at optimum condition was 13.46% compared to pure lubricant case using 80 g R600a, refrigerant mass charge. The maximum value of second law efficiency and the least value of exergy lost were found at 0.2 g/L concentration of hybrid nano-lubricant using 100 g charge of R600a refrigerant, with values of 77% and 96.90W, respectively. In conclusion, performance of VCR test rig altered when the concentrations of hybrid nano-lubricant and refrigerant mass concentrations changed.

Nomenclature

TiO2=

Titanium dioxide

SiO2=

silicon dioxide

MO=

Mineral oil

h=

specific enthalpy

VCR=

vapor compression refrigeration

COP=

coefficient of performance

η=

second law efficiency

S=

specific enthalpy

Te=

evaporator temperature

Tc=

condenser temperature

To=

ambient temperature

ΔSgen=

entropy generation

ΔSsys=

entropy change

Xdest=

total exergy destroyed

Wcomp=

input power or compressor work

Acknowledgements

We are grateful to the Maulana Azad National Institute of Technology, Bhopal, for providing the resources required to complete this research.

Disclosure statement

The authors state that they have no known financial or interpersonal conflicts that would have affected the research presented in this study.

Additional information

Notes on contributors

Ankit Kumar

Ankit Kumar is a Ph.D. scholar in Mechanical Engineering department at MANIT Bhopal, India. He works in the area of refrigeration and air-conditioning.

Satish Pal Singh Rajput

Dr. Satish Pal Singh Rajput is a professor in Mechanical Engineering Department at Maulana Azad National Institute of Technology Bhopal, Madhya Pradesh, India. He works in area of thermal engineering, refrigeration and air conditioning, energy conversion cycles and human thermal comfort.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.