Web-StrabNet: a web-based expert system for the differential diagnosis of vertical strabismus (squint)

, , &
Pages 89-97 | Received 07 Oct 2008, Accepted 20 Apr 2009, Published online: 08 Jan 2010
 

Abstract

A squint, also known as strabismus, is a condition where the eyes are misaligned because of incorrect balance in the controlling eye muscles. This may result from muscular, neuromuscular or purely mechanical factors. An affected eye will have either predominating vertical or horizontal deviation. Vertical deviations are usually classified into eight classes (diagnoses) and horizontal into 10. The present work considers only the former but extension to the latter is straightforward.

The differential diagnosis of strabismus is usually achieved in the prism cover test (PCT). A range of test prisms is presented to the eye and the resulting deviation in a particular direction of gaze is observed. In the full PCT, 10 positions of gaze are considered: in each position there are, say, 40 prisms of plus and minus power to investigate. The problem can be expressed as the inference 1-of-8 diagnoses in the output space from an input space of 10 parameters each with a resolution of 1-in-80. However, in the majority of clinical examinations, the corner-most positions of gaze are difficult to assess, particularly in children. Therefore, frequently the 6-position subset is reported requiring a corresponding reduction in the input space dimensions of 10 to 6. Web-StrabNet© is an expert system for the differential diagnosis of strabismus based on parallel instances of multi-layer perceptrons trained on exemplar data generated in consensus by two clinical experts. This machine expert is programmed in MatLab™ and is freely available as an Internet website (www.strabnet.com) which uses MatSOAP©, an XML/SOAP accessible automation server running a number of simultaneous MatLab instances.

StrabNet achieves diagnostic accuracies of 100 and >94% with artificial data and typically ∼99 and ∼99% in clinical data-sets for the 10-position and 6-position subset PCT's, respectively.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.