128
Views
2
CrossRef citations to date
0
Altmetric
Articles

Numerical simulation of a novel VRF-SV hybrid system performance in a large retail facility in the tropics

ORCID Icon & ORCID Icon
Pages 323-344 | Received 24 Jun 2021, Accepted 22 Feb 2022, Published online: 22 Mar 2022
 

Abstract

In this paper, the performance of an integrated variable refrigerant flow (VRF) system with the stratum ventilation (SV) system was numerically examined and compared with the experimental measurements in terms of temperature distribution and airflow patterns. In total six different configurations were designed and analyzed. The results suggest that configuration 5 was greatly satisfied the airflow movement needs. The positive thermal gradient with a modest airflow velocity (< 0.8 m/s) was setup in the entire breathing zone. The indoor temperature in the range of 20°C–22°C was seen throughout the occupied space, except for some places near the walls. Furthermore, a very strong airflow throw from the SV supply terminals was observed with the recommended value of face velocity. Hence, the VRF-SV hybrid system could achieve a better thermal comfort (TC) and indoor air quality (IAQ) in large ACMV applications.

Acknowledgements

The authors would like to thank the University of Malaya for providing Partnership Grant RK005-2020 and IIRG Grant IIRG014-2019A to the authors for research work to be conducted at the University of Malaya. Thanks are extended to the Pakistan Government for the full scholarship provided to the first co-author, Mr. A.R. Umair, for conducting PhD research work in the HVAC&R Lab at the Department of Mechanical Engineering, University of Malaya. In addition, special thanks are extended to Prudentaire Engineering Sdn Bhd and Daikin R&D Malaysia Sdn Bhd for their contributions in the laboratory testing conducted in this project.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Nomenclature

E=

Total energy

F=

Body forces

k=

Turbulent kinetic energy

l/s=

Liter per second

m=

Meter

mm=

Millimeter

m/s=

Meter per second

oz=

Occupied zone

Pa=

Pascal

σ=

Normal stress

T=

Temperature

τ=

Shear stress

ϵ=

Dissipation of turbulent kinetic energy

s=

Supply

ω=

Dissipation of turbulent kinetic energy into internal thermal energy

φ=

Energy dissipation

λ=

Bulk viscosity coefficient

ρ=

Density

t=

Time

u=

Velocity in X-direction

uz=

Unoccupied zone

v=

Velocity in Y-direction

w=

Velocity in Z-direction

x=

Coordinate and distance

y=

Coordinate and distance

z=

Coordinate and distance

Additional information

Funding

This work was supported by University of Malaya IIRG [grant number IIRG014-2019A]; University of Malaya Partnership [grant number RK005-2020].

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.