658
Views
13
CrossRef citations to date
0
Altmetric
Original Articles

Determination of anabolic agents in dietary supplements by liquid chromatography-high-resolution mass spectrometry

, , , &
Pages 635-647 | Received 19 Nov 2014, Accepted 30 Jan 2015, Published online: 04 Mar 2015
 

Abstract

A sensitive method for the identification and quantification of anabolic steroids and clenbuterol at trace levels in dietary supplements by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) in atmospheric pressure ionisation (APCI) mode using a single-stage Orbitrap analyser operating at a resolution power of 100 000 full width at half maximum (FWHM) was developed and validated. A total of 1 g of dietary supplement was added with testosterone-d3 as internal standard, dissolved in methanol, evaporated to dryness, diluted in sodium hydroxide solution and extracted with a mixture of pentane/ethyl ether 9:1. The extract was directly injected into the LC-HRMS system. The method was fully validated. Limits of detection (LODs) obtained for anabolic androgenic steroids (AASs) varied from 1 to 25 ng g−1 and the limit of quantitation (LOQ) was 50 ng g−1 for all analytes. The calibration was linear for all compounds in the range from the LOQ to 2000 ng g−1, with correlation coefficients always higher than 0.99. Accuracy (intended as %E) and repeatability (%CV) were always lower than 15%. Good values of matrix effect and recovery were achieved. The ease of the sample preparation together with a fast run time of only 16 min permitted rapid identification of the analytes. The method was applied to the analysis of 30 dietary supplements in order to check for the presence of anabolic agents not labelled as being present in these supplements. Many AASs were often detected in the same sample: indeed, androstenedione was detected in nine supplements, 5-androsten-3β-ol-17-one (DHEA) in 12, methandienone in three, stanozolol in one, testosterone in seven and testosterone esters in four of them. A retrospective analysis of suspected compounds not included at the beginning of the method development was also possible by means of the full acquisition spectra obtained with the HRMS technique.

Graphical Abstract

Additional information

Funding

This work was performed under the framework of the project ‘Smart-Stop’, funded by the Italian Antidrug Policies Department

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.