Optimizing performance of ceiling-mounted personalized ventilation system assisted by chair fans: Assessment of thermal comfort and indoor air quality

, &
Pages 412-430 | Received 28 Aug 2015, Accepted 17 Feb 2016, Published online: 13 Apr 2016
 

Abstract

This study investigates and optimizes the performance of ceiling-mounted personalized ventilation system when assisted with chair-mounted fans. Detailed computational fluid dynamics simulations were performed to study the velocity, temperature, and CO2 fields around the microclimate of the occupant. The computational fluid dynamics model was integrated with a bio-heat model to determine the corresponding segmental skin temperature and local and overall comfort and sensation. The computational fluid dynamics model was validated experimentally using a thermal manikin in a climatic chamber. The segmental skin temperature, velocity field, and CO2 field were validated experimentally. The predicted values and the measured values showed good agreement. The validated computational fluid dynamics model was used to optimize the height of the chair fan and the fan flow rate for the best combination of indoor air quality and thermal comfort. The chair fan's configuration to achieve the best thermal comfort and the best indoor air quality occurred at different fan heights. The optimal fan height and flow rate for best thermal comfort were 40 cm (15.75 in.) above floor level and 10 L/s (0.35 ft3/s), respectively. However, the optimal fan height and flow rate for best air quality were found to be 50 cm (19.69 in.) above the floor level and 10 L/s (0.35 ft3/s), respectively. At this configuration, the chair-mounted fans were able to reduce the thermal plumes and improve the performance of the personalized ventilation system by nearly doubling thermal comfort and ventilation effectiveness. The use of chair-mounted fans allowed for the achievement of energy savings up to 17% when compared with conventional mixing ventilation system.

Nomenclature: Symbols

C=

carbon dioxide concentration (ppm)

CF=

chair fan

CFD=

computational fluid dynamics

d=

diameter of the honeycomb holes, m (ft)

D=

diffusion of Carbon dioxide, m2/s (ft2/s)

DV=

displacement ventilation

H=

fan height above ground, cm (in.)

IAQ=

indoor air quality

MV=

mixing ventilation

PV=

personalized ventilation

=

total flow rate, L/s (ft3/s)

t=

thickness of the honeycomb flow straighteners, m (ft)

T=

temperature, °C (°F)

y+=

dimensionless wall thickness

Greek symbols

ϵ=

effectiveness

μ=

dynamic viscosity, kg/m·s (lbf·s/ft2)

ν=

kinematic viscosity, m2/s (ft2/s)

ρ=

density, kg/m3 (lbm/ft3)

Subscripts

B=

breathing zone

F=

fresh air

f=

fan

R=

return air

t=

turbulent

v=

ventilation

Additional information

Notes on contributors

Bachir El-Fil

Bachir El-Fil is an MS student.

Nesreen Ghaddar

Nesreen Ghaddar, PhD, Member ASHRAE, is a Professor.

Kamel Ghali

Ghali Kamel, PhD, Associate Member ASHRAE, is a Professor.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.