232
Views
0
CrossRef citations to date
0
Altmetric
Original Articles

Energy-optimized versus cost-optimized design of high-performing dwellings: The case of multifamily buildings

ORCID Icon, &
Pages 513-528 | Received 01 Oct 2017, Accepted 27 Feb 2018, Published online: 19 Apr 2018
 

Abstract

Living in multifamily buildings is very common in Italy, and it is important to optimize the design strategies to minimize the energy demand of these buildings and their related operational costs. This is particularly important for low-income tenants and is pursued by many social housing developments where a good energy performance design is reached. In this work, a simulation-based optimization methodology that combines the use of TRNSYS with GenOpt is applied to minimize two objective functions—the annual primary energy demand and the operational energy cost—in different system technology scenarios, and to verify the differences between energy-optimized design and cost-optimized design in a Northern Italy climate. The study is performed on a typical floor of a real multifamily building for social housing. The envelope optimization demonstrates a potential reduction of the energy demand and cost for heating and cooling of more than 35%. The relationship between optimal solutions, system technology scenarios, and optimization objectives is deeply analyzed. It is possible to find a set of design solutions that is optimal for all analyzed scenarios. This provides a set of design alternatives that is close to the environmental optimum and is able to reduce low-income tenants' vulnerability.

Nomenclature
Acronyms
DH=

district heating

EC=

electric chiller

EHP=

electric heat pump

GAC=

gas-absorption chiller

GCB=

gas-condensing boiler

GHP=

gas heat pump

INI=

initial building configuration

OPT=

optimal building configuration

PSO=

particle swarm optimization algorithm

Latin letters
abN=

solar absorption coefficient of external wall, north facade

abS=

solar absorption coefficient of external wall, south facade

abWE=

solar absorption coefficient of external wall, west, east facade

Blr=

width of the window at the ground floor on the south facade (m)

Bm=

width of the window at the first floor on the south facade (m)

C=

operational cost (€)

c=

specific energy cost (€/kWh)

fpe=

primary energy conversion factor

inWN=

thermal resistance of wall insulation, north facade (m²K/W)

inWS=

thermal resistance of wall insulation, south facade (m²K/W)

inWE=

thermal resistance of wall insulation, west, east facade (m²K/W)

Loggia N=

depth of north loggia (m)

Loggia S=

depth of south loggia (m)

Lagg S=

depth of fixed shadings on the south facade windows (m)

OF=

objective function

PE=

primary energy (kWh)

p=

parameter

s=

parameter variation step

Q=

energy need (kWh)

w=

weight

WTE=

window type of east, west facades (-)

WTN=

window type of north facade (-)

WTNL=

window type of north loggia facade (-)

WTS=

window type of south facade (-)

WTSL=

window type of south loggia facade (-)

WW=

window width (m)

Subscripts
c=

cooling

h=

heating

Additional information

Funding

Compagnia di San Paolo [Starting Grant 2016].

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.