The influence of technical parameters on diameter distribution of nickel particles in electrical discharge machining

, , & ORCID Icon
Pages 477-484 | Received 28 Mar 2021, Accepted 29 Aug 2021, Published online: 27 Sep 2021
 

Abstract

The effect of technological parameters on the nickel Nano-microparticles diameter by electrical discharge machining is studied. The results show that the range of particle sizes is suitable for different voltage and pulse widths. With a high voltage value, the ratio of hollow particles with a size of 5 µm is low. With particle sizes in the range of 25–50 µm, the number of particles is concentrated at the high voltage of 30 and 60 A. The range of particle sizes is from 5 to 20 µm, however, the number of particles is concentrated at low voltage values of 9 and 15 A. When the pulse width is small, 120 and 300 μs, it can be seen the concentration and a large number of particle sizes of 10–25 μm. Conversely, when the pulse width is 700 μs, the dispersed particle size can be observed and the number of particles that is larger than 35 μm accounts for more than 20%.

Acknowledgements

Thanks to the supports from School of Mechanical Engineering – Vietnam Maritime University. This is appreciated acknowledgment for our to complete this study.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.