Publication Cover
Chronobiology International
The Journal of Biological and Medical Rhythm Research
Volume 18, 2001 - Issue 3
287
Views
57
CrossRef citations to date
0
Altmetric
Original

CIRCADIAN RHYTHM OF DOUBLE (RATE-PRESSURE) PRODUCT IN HEALTHY NORMOTENSIVE YOUNG SUBJECTS

, , , , &
Pages 475-489 | Received 07 Nov 2000, Accepted 15 Feb 2001, Published online: 07 Jul 2009
 

Abstract

The double product (DP), systolic blood pressure multiplied by heart rate, is a surrogate measure of myocardial oxygen demand and cardiac workload used increasingly today in medicine. The double product is more strongly correlated with left ventricular mass than the daily blood pressure mean. The purpose of this study was to describe the normative circadian pattern of the double product in healthy normotensive young adults. We studied 125 men and 75 women, 23.0 ± 3.3 (mean ± SD) years of age, without medical history of hypertension and 24h ambulatory systolic/diastolic blood pressure mean consistently below 135/85 mm Hg. Subjects underwent ambulatory blood pressure monitoring at 30-minute intervals for 48 consecutive hours once each season of the year, yielding 930 protocol-correct blood pressure and heart rate time series. Subjects maintained their usual routine of diurnal activity and nocturnal sleep and avoided use of over-the-counter and other medication. Circadian rhythmicity in the double product was established by population multiple-component analysis. The double product rose rapidly from the lowest value, attained 3h before awaking from sleep at night, to a markedly elevated level at the commencement of morning activity. The double product was highest in the afternoon, roughly 7h after the commencement of diurnal activity. In both men and women, the shape of the highamplitude circadian rhythm in the double product was best described by a complex model composed of three cosine curves having periods of 24h, 12h, and 6h. The 24h mean in the double product of 8092.51 ±42.76 (mean ±SD) in men was significantly lower than that of 8353.17 ±37.48 in women (P <.001). The circadian double amplitude of the rhythm was statistically significantly greater (P <.001) in men (50% of the 24h mean) than women (44% of the 24h mean). The double product did not differ between seasons in women, but it did in men (P =.017) due to reduced heart rate in summer. The circadian pattern of large amplitude in the double product and its gender differences must be taken into account when using this variable to assess cardiac workload, risk of left ventricular hypertrophy, and efficiency of antihypertensive therapy. (Chronobiology International, 18(3), 475–489, 2001)

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.