353
Views
13
CrossRef citations to date
0
Altmetric
Original Articles

Improvement of Sensitivity for the Determination of Propylene Glycol in Rat Plasma and Lung Tissue Using HPLC/Tandem MS and Derivatization with Benzoyl Chloride

, , , , &
Pages 3413-3431 | Received 14 Jan 2003, Accepted 20 Feb 2003, Published online: 17 Aug 2006
 

Abstract

Propylene glycol (PG), a simple alcohol, is a commonly used vehicle for aerosol dosage formulations. Quantification of PG in plasma and lung tissue is, therefore, important for new drug development. We describe a highly sensitive and selective method for the quantitative determination of PG in rat plasma and lung tissue, using liquid chromatography (LC) with positive atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS) detection. Propylene glycol and the internal standard (IS) 1,4‐butanediol were derivatized with benzoyl chloride under alkaline conditions to enhance the sensitivity of detection. Ionization efficiency was improved following derivatization. The limits of detection (LOD) for rat plasma and rat lung tissue were 0.269 µg/mL and 1.12 µg/g, respectively. The LOQs for rat plasma and lung tissue were 0.448 µg/mL and 1.62 µg/g, respectively. Calibration curves were linear from 2 to 4000 µg/mL for rat plasma (r = 0.9990) and from 2 to 2400 µg/g for rat lung tissue (r = 0.9985). The assay showed intra‐assay and inter‐assay precision (%RSD) of 3.8–4.8% (n = 6) and 4.2–6.6% (n = 18) for rat plasma, 3.8–4.0% (n = 6) and 6.5–7.4% (n = 18) for rat lung tissue, respectively. The percent inaccuracy for inter‐assay results in rat plasma were 2.5–4.7% and in rat lung tissue were 1.3–6.8% for different concentrations. All plasma and lung tissue samples demonstrated acceptable freeze/thaw stability, bench stability, and prepared sample stability over a 24 hours period. An alternative derivatizing method using perfluorooctanoyl chloride with negative APCI/MS detection was investigated. Although strong fragment ions of the derivatives could be detected, the feasibility of this method was limited by sample preparation. Additionally, fragment ions produced from the perfluorooctanoyl moiety lacked selectivity. The benzoyl chloride method is proved to be more sensitive, selective, and robust.

Acknowledgments

These studies were financially supported by Chrysalis Technologies Inc. The authors would like to thank Dr. Zong‐Ping Zhang for helpful suggestions and discussions during these experiments.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.