165
Views
4
CrossRef citations to date
0
Altmetric
Systematic Review

Tessellated fundus appearance and its association with myopic refractive error

, , , , , & show all
Pages 378-384 | Received 26 Apr 2018, Accepted 06 Jul 2018, Published online: 15 Apr 2021
 

Abstract

The appearance of tessellated fundus in an eye may act as a marker in identifying visual performance, degree of myopia or risk of progression of myopia in a given eye. A systematic literature search using key words was performed using PubMed, Web of Science and Google Scholar and of the 832 studies identified, 10 full‐length articles, which met the inclusion criteria, were considered for review. The primary outcome measures were association of tessellated fundus with: (i) visual acuity, (ii) refractive error, (iii) axial length, (iv) choroidal thickness and (v) future progression of myopia when compared to either no myopic maculopathy, or more severe myopic maculopathy. There was no significant difference in the visual acuity noted between eyes with normal fundus and tessellated fundus appearance. Compared to eyes with tessellated fundus, eyes with more severe myopic maculopathy had a four‐line decrease in best‐corrected visual acuity, more myopia (mean difference 2.75 D, range 0.285.78 D) and a longer axial length (mean difference 2-mm, range 2.29 to 1.71-mm). Eyes with tessellated fundus generally exhibited a significant decrease in choroidal thickness compared to eyes with no maculopathy. In mostly older individuals, eyes with tessellated fundus had a better outcome with respect to visual acuity, degree of myopia and axial length compared to other severe myopic maculopathies, but had a worse outcome for choroidal thickness and degree of myopia, compared to eyes with no myopic maculopathy. The features such as reduced choroidal thickness combined with a predilection to infra‐temporal and parapapillary regions may indicate regions of stress that are prone to more stretching/atrophic changes. This systematic review demonstrated an association of tessellated fundus with visual acuity, refractive error, axial length and choroidal thickness and hence emphasises the documentation of the presence and location of tessellated fundus appearance that may help in predicting the progression of myopia.

ACKNOWLEDGEMENT

We thank Dr Judith Flanagan, Brien Holden Vision Institute, for guidance and revision of the manuscript and providing valuable suggestions related to the paper.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.