Static and dynamic pupil characteristics in pseudoexfoliation syndrome and glaucoma

, MD, , MD, , MD, , MD, , MD & , MD
Pages 332-338 | Received 30 Mar 2019, Accepted 23 Jun 2019, Published online: 15 Apr 2021
 

Abstract

Background

To compare the static and dynamic pupillometry measurements in patients with pseudoexfoliation syndrome (PES), patients with pseudoexfoliation glaucoma (PEG) and age‐matched healthy subjects using an automatic quantitative pupillometry system.

Methods

This prospective, cross‐sectional study consisted of 40 patients with PES, 30 patients with PEG and 43 control subjects. Static pupillometry measurements including scotopic pupil diameter, mesopic pupil diameter, low photopic pupil diameter, and high photopic pupil diameter were undertaken. Subsequently, dynamic pupillometry measurements including resting diameter, amplitude of pupil contraction, latency of pupil contraction, duration of pupil contraction, velocity of pupil contraction, latency of pupil dilation, duration of pupil dilation, and velocity of pupil dilation were undertaken. These measurements were compared between the groups.

Results

The scotopic, mesopic, and low photopic pupil diameter values were statistically significantly lower in patients with PES and PEG compared with controls (p < 0.001). However, these parameters were similar between the patients with PES and PEG (p > 0.05). The mean values of high photopic pupil diameter were similar within all groups (p = 0.54). The amplitude of pupil contraction values of the patients with PEG was statistically significantly lower than the patients with PES and the controls (p < 0.05). Patients with PES also had significantly lower amplitude of pupil contraction values compared with controls (p < 0.001). Additionally, the velocity of pupil contraction values was statistically significantly higher in control subjects when compared to the patients with PES and PEG (p < 0.05).

Conclusion

This study demonstrated that accumulation of pseudoexfoliative material can cause alterations in static and dynamic pupillary characteristics and the progression from PES to PEG may be associated with reduced amplitude of pupil contraction values.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.