14
Views
4
CrossRef citations to date
0
Altmetric
Research Papers

Validity of first post‐operative day automated refraction following dense cataract extraction

, MD, , MRCOphth & , FRCOphth
Pages 187-192 | Received 04 Apr 2010, Accepted 13 Oct 2010, Published online: 15 Apr 2021
 

Abstract

Background:  The aim of this study was to assess the refractive stability and validity of automated refraction obtained at day one after surgery for dense cataracts in a developing country setting, where patient follow‐up is often erratic.

Methods:  In a prospective study in rural Kenya, we compared automated refraction and visual acuity (VA) after manual small incision cataract surgery (SICS) and phacoemulsification cataract surgery (Phaco) at day one with autorefraction and subjective refraction obtained at a later visit.

Results:  Ninety eyes of 83 patients fulfilled the ultimate inclusion criteria (21 SICS eyes and 69 Phaco eyes). The correlation between refraction at day one and at a later follow‐up was moderately good for both SICS and Phaco (R1 = 0.61 and R2 = 0.58). Spherical equivalent (SE) values measured at day one were within one dioptre of those obtained later in 68 eyes (72 per cent); (SICS: 67 per cent; Phaco: 74 per cent) and within two dioptres in 83 eyes (92 per cent); (SICS: 86 per cent; Phaco: 94 per cent). At post‐operative days 14, 28 and more than 42 for SICS and Phaco eyes, the mean SE was 0.58 and 0.48, 0.55 and 0.19, and 0.9 and 0.31 more hypermetropic than the mean SE of post‐operative day one, respectively. First‐day accuracy was higher in eyes with better pre‐operative VA, softer cataracts and lower post‐operative prediction error. The surgical technique (SICS versus Phaco) had no influence on first‐day accuracy in our set‐up.

Conclusion:  Refractive data from the early post‐operative period can provide useful data for qualitative control and monitoring of post‐operative refractive outcomes in a setup, where ‘better’ data are often not available; however, its accuracy is limited and, ultimately, there is no alternative to good follow up of operated patients.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.