Toric implantable collamer lens for high myopic astigmatism in keratoconic patients after six months

, MD, , MD FICO, , MD, , MD, , MD & , MD
Pages 225-232 | Received 14 Dec 2011, Accepted 05 May 2012, Published online: 15 Apr 2021
 

Abstract

Background

The aim was to evaluate the safety, efficacy, stability and predictability of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia and myopic astigmatism associated with keratoconus.

Methods

The unaided vision and visual acuity, refraction and adverse events were measured in 22 keratoconic eyes of 14 patients after using an implantable collamer lens (ICL) (STAAR Surgical Inc.) to correct refractive error. The outcome was evaluated over six months.

Results

The mean pre‐operative spherical equivalent (SE) and cylinder changed from ‐4.98 ± 2.63 DS and ‐2.77 ± 0.99 DC to ‐0.33 ± 0.51 DS and ‐1.23 ± 0.65 DC, respectively at the end of six months. Before the surgery the mean Snellen decimal visual acuity was 0.63 ± 0.20. The mean unaided vision and visual acuity changed to 0.76 ± 0.23 and 0.85 ± 0.21, respectively at the end of six months. The mean safety and efficacy indices were 1.40 ± 0.32 and 1.24 ± 0.34, respectively. No eye lost a line of visual acuity and 17 eyes (77.3 per cent) gained one or more lines. Fifteen eyes (68.2 per cent) were within 0.50 D and 20 (90.9 per cent) were within 1.00 D of the desired spherical equivalent refraction. There was a change in manifest refraction of 0.09 ± 0.21 (ranging from ‐0.25 to +0.75) from one week to six months after the surgery.

Conclusion

The clinical outcomes of the current study demonstrate the safety, efficacy and predictability of toric implantable collamer lens in the correction of myopia and myopic astigmatism associated with keratoconus. The patients' refractions achieved early stability and remained stable during the course of the study.

This paper was presented as an oral presentation at the European Society of Cataract and Refractive Surgery meeting in September 2011.

This paper was presented as an oral presentation at the European Society of Cataract and Refractive Surgery meeting in September 2011.

Notes

This paper was presented as an oral presentation at the European Society of Cataract and Refractive Surgery meeting in September 2011.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.