Alignment efficiency and discomfort of three orthodontic archwire sequences: a randomized clinical trial

, &
Pages 32-39 | Received 06 Oct 2010, Accepted 16 Nov 2010, Published online: 16 Dec 2014
 

Abstract

Aim: To compare the efficiency of orthodontic archwire sequences produced by three manufacturers.

Design: Prospective, randomized clinical trial with three parallel groups.

Setting: Private orthodontic practice in Caloundra, QLD, Australia

Subjects and methods: One hundred and thirty‐two consecutive patients were randomized to one of three archwire sequence groups: (i) 3M Unitek, 0·014 inch Nitinol, 0·017 inch×0·017 inch heat activated Ni–Ti; (ii) GAC international, 0·014 inch Sentalloy, 0·016×0·022 inch Bioforce; and (iii) Ormco corporation, 0·014 inch Damon Copper Ni–Ti, 0·014×0·025 inch Damon Copper Ni–Ti. All patients received 0·018×0·025 inch slot Victory SeriesTM brackets.

Outcome measures: Mandibular impressions were taken before the insertion of each archwire. Patients completed discomfort surveys according to a seven‐point Likert Scale at 4 h, 24 h, 3 days and 7 days after the insertion of each archwire. Efficiency was measured by time required to reach the working archwire, mandibular anterior alignment and level of discomfort.

Results: No significant differences were found in the reduction of irregularity between the archwire sequences at any time‐point (T1: P = 0·12; T2: P = 0·06; T3: P = 0·21) or in the time to reach the working archwire (P = 0·28). No significant differences were found in the overall discomfort scores between the archwire sequences (4 h: P = 0·30; 24 h: P = 0·18; 3 days: P = 0·53; 7 days: P = 0·47). When the time‐points were analysed individually, the 3M Unitek archwire sequence induced significantly less discomfort than GAC and Ormco archwires 24 h after the insertion of the third archwire (P = 0·02). This could possibly be attributed to the progression in archwire material and archform.

Conclusions: The archwire sequences were similar in alignment efficiency and overall discomfort. Progression in archwire dimension and archform may contribute to discomfort levels. This study provides clinical justification for three common archwire sequences in 0·018×0·025 inch slot brackets.

Acknowledgments

This study was supported by a grant from the Australian Society of Orthodontists’ Foundation for Research and Education.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.