516
Views
9
CrossRef citations to date
0
Altmetric
Review

3D creep cavitation characteristics and residual life assessment in high temperature steels: a critical review

, , &
Pages 603-626 | Received 03 Apr 2014, Accepted 08 Oct 2014, Published online: 22 Oct 2014
 

Abstract

The need for a new paradigm to estimate remaining creep life of service exposed steels is critically assessed. New approaches to residual life assessment are proposed, in the light of a decade’s experience of the use of micro-tomography to characterise the three-dimensional (3D) nature of cavitation damage in structural materials. Imaging of conventional structural materials such as steels with high absorption to X-rays has been realised by synchrotron micro-tomography (SR-μCT), providing new insights into phenomena such as creep failure. The unique feature of SR-μCT studies is the direct imaging in 3D of cavities (hundreds of micrometres in size) present in the bulk, revealing the spatial characteristics and morphology of the creep voids. Quantitative analyses of the cavitation characteristics revealed by 3D datasets, when scaled with respect to time, stress and temperature, provide functional information suitable for developing constitutive equations for creep. The application of SR-μCT, a non-destructive technique providing high fidelity data, significantly reduces the ambiguity in developing functional relationships to predict creep failure. The explicit use of such constitutive equations to estimate the residual life of components in creep, and the consequent assessment of structural integrity, would prove invaluable. Micro-tomography studies related to creep in materials are reviewed, with special emphasis on a 10·86%Cr heat resistant steel, to demonstrate the type of data available for life assessment and design against creep failure. A brief discussion of current methods to estimate residual life in the light of recent 3D micro-tomography data follows. Finally, the possibility of new approaches, using micro-tomography data in conjunction with destructive 3D approaches such as serial sectioning, to formulate advanced residual life estimates, is briefly considered.

Acknowledgements

C. Gupta would like to thank JASRI for the award of beam times 2011B1164 and 2012A1049 and the staff of SPring-8 for support during the work that provided familiarisation with the versatile capabilities of micro-tomography that underpins the present review. C. Gupta also thanks the Director Materials Group, Bhabha Atomic Research Centre, Mumbai, India for support during the preparation of the manuscript.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.