The scope of Nuclear Electric's (NE) requirements for irradiated fuel transport and the relevant safety and regulatory compliance standards are outlined. To illustrate NE's approach to demonstrating package design compliance the basis of the safety case for unbottled Magnox fuel transport in the Mk M2 Magnox flask is described. The considerations which lay behind the development of the Mk A2 AGR Flask are indicated and a description is given of the main design features of this flask. Finally there is a summary of progress in obtaining Type B(M) approvals, based on the 1985 IAEA Regulations, for the requisite range of flask contents.