Recent Progress of the LHD Thomson Scattering System

, , , , , & show all
Pages 345-351 | Published online: 07 Apr 2017
 

Abstract

The Large Helical Device (LHD) Thomson scattering system measures electron temperature and density profiles of LHD plasmas along the LHD major radius at a horizontally elongated section. The LHD Thomson scattering system has an oblique backward-scattering configuration. The number of observation points and typical spatial resolution are 144 and 17 mm, respectively. The temporal sampling frequency is 10 to 100 Hz. Measurable temperature and density ranges are Te = 5 eV to 20 keV and ne ≥ 1018 m-3, respectively. The LHD Thomson scattering system consists of several subsystems: laser system, light collection optics, polychromators, and data acquisition system. In the past decade, we have continued our efforts to improve the performance and reliability of the LHD Thomson scattering system through extension of measurable temperature and density ranges, Raman and Rayleigh calibrations for absolute density measurements, new laser beam positioning system, and plasma light monitor system for increasing data reliability. In this paper, we describe the recent progress of the LHD Thomson scattering system in detail.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.