A Computer Program for Assessment of Emergency Operation Procedures under Non-LOCA Transient Conditions in BWRs

Pages 465-474 | Published online: 10 May 2017
 

Abstract

A program analyzing long-term transients after abnormal incidents, excluding loss-of-coolant accidents, has been developed to assess emergency operation procedures for cold shutdown of reactors. The main program features are:

1. The thermal hydraulics in both the reactor pressure vessel (RPV) and the primary containment vessel (PCV) are treated.

2. Analytical models of the cooling system are included for not only the emergency core cooling system but other cooling systems that are effective for RPV and PCV cooling.

3. The on/off switching of cooling systems by plant interlocks, component failures, and operator actions is simulated.

The applicability of this program has been evaluated by simulation of long-term thermal-hydraulic behavior of the boiling water reactor transients initiated by loss of feedwater. From the evaluation results, it has been confirmed that the main program models can assess emergency operation procedures.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.