Quality Assurance Verification of High-Flux Isotope Reactor Fuel Elements by the 252Cf-Source-Driven Noise Analysis Method

&
Pages 205-223 | Published online: 10 May 2017
 

Abstract

The method used since 1970 for determining the subcriticality of High-Flux Isotope Reactor (HFIR) fuel elements submerged in water is to add extra reactivity-calibrated uranium fuel plates and neutron absorber strips to a fuel element in order to achieve delayed criticality when it is submerged in water. This quality assurance (QA) verification determines that a fuel element meets reactivity specifications before it is used in the reactor.

The use of the 252Cf-source-driven neutron noise analysis method to measure the subcriticality of fuel elements as an alternate to the critical experiment method was investigated by performing experiments with 29 HFIR fuel elements submerged in water. Reactivity was also measured by the break frequency noise analysis method. These measurements have shown that the 252Cf-source-driven noise analysis method can be used to determine whether HFIR fuel elements are fabricated within design specification by measuring the subcritical neutron multiplication factor of the fuel element submerged in water without the need to achieve delayed criticality. These subcritical measurements can replace the existing critical experiments for QA testing of fuel elements before use in a reactor and would be a more accurate and cost-effective method with reduced personnel radiation exposure and increased nuclear criticality safety.

In addition, these experiments have shown that (a) measurements can be made with the detectors outside the water reflector tank; (b) the results do not depend on the type of detector used (neutron sensitive, gammaray sensitive, or sensitive to both neutrons and gamma rays); and (c) the method can measure the reactivity of the fuel element partially submerged and has the sensitivity to determine the effects of small uranium mass changes (∼1%) in the fuel element while the element is partially flooded (approximately half submerged) and very far subcritical. Validation of this method on these fuel elements suggests a potential for broad application of the 252Cf-source-driven noise analysis for QA testing of water reactor fuel elements where it is possible to submerge the elements in water without achieving a delayed critical state.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.