Radiofrequency catheter ablation of Type 1 atrial flutter using a large-tip electrode catheter and high-power radiofrequency energy generator

Pages 187-192 | Published online: 09 Jan 2014
 

Abstract

Recent studies have demonstrated a high degree of efficacy of 8 mm electrode-tipped or saline-irrigated-tip catheters for ablation of atrial flutter (AFL). These catheters have a theoretical advantage as they produce a large ablation lesion. However, large-tip ablation catheters have a larger surface area and require a higher power radiofrequency (RF) generator with up to 100 W capacity to produce adequate ablation temperatures (50–60°C). The potential advantages of a large-tip ablation catheter and high-power RF generator include the need for fewer energy applications, shorter procedure and fluoroscopy times, and greater efficacy. Therefore, the safety and efficacy of AFL ablation using 8 or 10 mm electrode catheters and a 100-W RF generator was studied using the Boston Scientific, Inc., EPT-1000 XP™ cardiac ablation system. There were 169 patients, aged 61 ± 12 years involved. Acute end points were bidirectional isthmus block and no inducible AFL. Following ablation, patients were seen at 1, 3 and 6 months, with event monitoring performed weekly and for any symptoms. Three quality of life surveys were completed during follow-up. Acute success was achieved in 158 patients (93%), with 12 ± 11 RF energy applications. The efficacy of 8 and 10 mm electrodes did not differ significantly. The number of RF energy applications (10 ± 8 vs. 14 ± 8) and ablation time (0.5 ± 0.4 vs. 0.8 ± 0.6 h) were less with 10 mm compared with 8 mm electrodes (p < 0.01). Of 158 patients with acute success, 42 were not evaluated at 6 months due to study exclusions. Of the 116 patients evaluated at 6 months, 112 (97%) had no AFL recurrence. Of those without AFL recurrence at 6 months, 95 and 93% were free of symptoms at 12 and 24 months, respectively. Ablation of AFL improved quality of life scores (p < 0.05) and reduced anti-arrhythmic and rate control drug use (p < 0.05). Complications occurred in six out of 169 patients (3.6%) but there were no deaths. It was concluded that ablation of AFL with 8 or 10 mm electrode catheters and a high-power RF generator was safe, effective and improved quality of life. The number and duration of RF applications was lower with 10 mm compared with 8 mm electrode catheters.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.