Abstract
Patient–ventilator asynchrony refers to the uncoupling between the mechanically delivered breath and the patient’s respiratory effort. It is common during assisted mechanical ventilation and may affect the morbidity of critically ill patients. Close inspection of pressure, volume and flow waveforms – displayed by modern ventilators – may help the physician to recognize and act appropriately to minimize patient–ventilator asynchrony. During the last two decades new modes of assisted mechanical ventilation have been introduced, aiming to improve patient ventilator synchrony by modulating the triggering function and the variables that control the flow delivery and the cycling off.
Financial & competing interests disclosure
The authors have no relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript. This includes employment, consultancies, honoraria, stock ownership or options, expert testimony, grants or patents received or pending, or royalties.