Efficacy of a trunk orthosis with joints providing resistive force on low-back load in elderly persons during static standing

, , , &
Pages 1413-1420 | Published online: 01 Sep 2015

Abstract

Purpose

Postural alignment of elderly people becomes poor due to aging, possibly leading to low-back pain and spinal deformity. Although there are several interventions for treating these conditions, no previous study has reported the effectiveness of a spinal orthosis or lumbosacral orthosis (LSO) in healthy elderly people without specific spinal deformity. We therefore developed a trunk orthosis to decrease low-back muscle activity while training good postural alignment through resistive force provided by joints with springs (here, called the ORF, which stands for orthosis with joints providing resistive force) as a preventive method against abnormal posture and low-back pain in healthy elderly persons.

Patients and methods

Fifteen community-dwelling elderly men participated in this study. Participants stood freely for 10 seconds in a laboratory setting under three conditions: without an orthosis, with the ORF, and with an LSO. The Damen corset LSO was selected as it is frequently prescribed for patients with low-back pain. Postural alignment during static standing was recorded using a three-dimensional motion capture system employing infrared cameras. Two force plates were used to record center of pressure. Electromyograms were obtained for bilateral erector spinae (ES), left internal abdominal oblique, and right gluteus medius muscles.

Results

Pelvis forward tilt angle tended to increase while wearing the ORF and decrease while wearing the LSO, but these results were not significant compared to no orthosis. Thorax extension angle and thorax angle on pelvis coordinate system significantly increased while wearing the ORF compared to the other two conditions. ES activity significantly decreased while wearing the ORF compared to the other two conditions. Internal oblique activity was significantly smaller while wearing the LSO than with no orthosis. Center of pressure did not significantly differ among the conditions.

Conclusion

The ORF significantly improved trunk alignment and decreased ES activity in healthy elderly subjects during static standing.

Introduction

Postural alignment worsens gradually over the course of aging.Citation1 This poor postural alignment, which manifests as spinal kyphosis, can result in irreversible degeneration of the intervertebral disks and ligaments. It also often causes postural instability and leads to vertebral bone fracture and increased risk of falling.Citation2,Citation3

Due to these problems, various interventions are used for elderly persons who have spinal deformity to improve postural alignment. Battaglia et alCitation4 reported that exercise improved spinal flexibility, and Imagama et alCitation5 reported the improvement of lumbar lordosis angle, sagittal balance, and back muscle strength in elderly patients through a training program that included muscle strength and spinal range of motion exercises.

Spinal orthoses provide a way to directly modify the posture of elderly persons with spinal misalignment. Piffer et alCitation6 reported that use of a newly designed spinal orthosis, the Spinomed® (medi GmbH & Co. KG, Bayreuth, Germany), for 6 months improved muscle strength, body balance, kyphosis angle, and vital capacity in elderly patients with osteoporosis. Ishida et alCitation7 reported that a rucksack-type orthosis instantly modified spine alignment and decreased erector spinae (ES) activity in elderly patients with kyphosis.

As mentioned earlier, previous studies have reported that exercise and orthotic therapy are effective in treating the elderly with spinal misalignment. It is, however, also important to offer preventive intervention for the healthy elderly. Costantino et alCitation8 reported that chronic low-back pain (LBP) in elderly people without specific spinal deformity could be effectively treated using a back school program, including exercise therapy for rehabilitation. However, to our knowledge, no previous studies have reported the effectiveness of a spinal orthosis or lumbosacral orthosis (LSO) in healthy elderly people without specific spinal deformity. A review of data from the Cochrane Database also found no evidence for the efficacy of lumbar support for decreasing low-back load.Citation9 In addition, Rostami et alCitation10 reported that use of an LSO for 4 weeks resulted in decreased trunk core muscle volume, and therefore, the drawback of long-term corset use may exceed the benefits.

In a previous study, to provide a preventive method against abnormal posture and LBP in elderly persons, we designed a trunk orthosis to address these issues by training good postural alignment while decreasing low-back load via resistive force provided by joints with springs ().Citation11 This orthosis with joints providing resistive force (hereafter, the ORF) produces a resistive moment that rotates the trunk backward and the pelvis forward (). Resistive moment applied to the trunk can not only rotate it backward to shift the center of gravity of the head, arms, and trunk to the L4/L5 joint but also directly decrease low-back extension moment because the resistive moment work is in the same direction as that produced by ES activity. In addition, reaction moment can promote forward rotation of the pelvis, and this effect can also facilitate extension of the thorax. The ORF may therefore improve alignment and decrease ES activity in elderly people. Indeed, our recent studies reported that the ORF improved trunk alignment and gait performance of hemiparetic patientsCitation11 and elderly persons during level walking.Citation12 However, we did not examine the effect of the ORF on ES activity and spinal alignment during static standing.

Figure 1 Trunk ORF.

Notes: (A) Wearing ORF without resistive force on the chest, (B) wearing ORF with resistive force on the chest, (C) detail of link mechanism.

Abbreviation: ORF, orthosis with joints providing resistive force.

Figure 1 Trunk ORF.Notes: (A) Wearing ORF without resistive force on the chest, (B) wearing ORF with resistive force on the chest, (C) detail of link mechanism.Abbreviation: ORF, orthosis with joints providing resistive force.

Figure 2 Biomechanical effect of ORF while static standing.

Abbreviation: ORF, orthosis with joints providing resistive force.
Figure 2 Biomechanical effect of ORF while static standing.

In light of the finding of no decrease in low-back muscle activity using LSOs,Citation9 this study aimed to examine, through biomechanical analysis, the effects of the ORF on healthy elderly people during static standing and to compare the effects with those of an LSO and no orthosis. We hypothesized that wearing the ORF would effectively decrease ES activity and modify trunk alignment in healthy elderly people during static standing.

Material and methods

Participants

We enrolled 15 healthy community-dwelling elderly men (mean age, 67.7±6.1 years; mean height, 162.4±5.7 cm; mean weight, 62.3±7.8 kg) from a group of 31 candidates. We excluded those with neurological disease, pain, history of orthopedic surgery, history of orthopedic treatment within the past 5 years, and history of LBP within the past 1 year. In the first phase of recruitment, we identified only two female subjects willing to participate in our study; however, due to a history of orthopedic treatment within the past 5 years, they were excluded. Therefore, we decided not to include any female subjects to mitigate the potential effects of sex and orthopedic disease. All participants provided written informed consent, and the study was approved by the ethics committees of the participating institutions, International University of Health and Welfare.

Features of the ORF

The features of the ORF ( and ) were described in our previous report.Citation11 Briefly, the ORF weighs 0.99 kg and has a 40° range of motion. Pelvic and upper supports are placed on the ileum and sternum, respectively. Stainless steel joints are connected to the upper support, with a nylon pad, and also to the pelvic support. These joints employ extension springs to produce tension, which is translated by a link mechanism into a resistive moment on the chest and a reaction moment on the posterior pelvis. The upper support initially inclines backward to exert resistive force on the chest and is then released via a mechanism that pulls tension levers downward. The resistive force can be increased or decreased via adjustment screws. The ORF is currently an investigational product that is not FDA-approved or approved by the corresponding national agency for the indication described herein.

Experimental conditions

Participants freely stood for 10 seconds under three conditions in the laboratory setting: with no orthosis, with the ORF, and with an LSO (Damen Corset, Pacific Supply, Osaka, Japan; ). As the Damen corset is frequently prescribed for patients with LBP, it was selected for use in this study. Our previous study reported carry-over effects of the ORF on body alignment of hemiparetic patients after removal while level walking.Citation11 We therefore decided to measure two trials without intervention (no orthosis) first, after which subjects completed the two orthosis trials in random order. Participants were given 5 minutes to become accustomed to wearing the orthoses, and there was a minimum rest interval of 5 minutes between conditions. Resistive force exerted on the chest was measured in real time with a strain gauge (Compression load cell LCN-A, Kyowa, Tokyo, Japan). The force data were transferred to a laptop via Bluetooth. Force was set to 20–25 N during static standing, and pressure between the corset and abdomen was set to 10 mmHg in all measurement conditions.Citation13 To obtain maximal voluntary contraction (MVC) values for normalization of individual muscle activities, participants performed maximal isometric contractions against gravity, while the experimenter (a licensed therapist) applied maximum resistance.Citation14 After practicing stable isometric contraction efforts, single maximal contractions of each muscle were recorded according to Daniels and Worthingham’s Muscle Testing. Subjects performed contractions against gravity, with maximum resistance applied by the examiner in the supine position to obtain MVC of the left internal abdominal oblique (IO) muscle (lifting head and shoulders from the table with right elbow toward left knee against imposed resistance to the right shoulder region), in the prone position to obtain MVC of the bilateral ES (back extension with hands resting on head against imposed resistance to the scapular region), and in the side-lying position with test leg elevated to obtain MVC of the right GM muscle (abduction with limb slightly extended beyond the midline and the pelvis rotated slightly forward while imposing resistance to the lateral surface of the knee).

Figure 3 Experimental conditions.

Notes: (A) Without an orthosis, (B) with the LSO, (C) with the ORF.
Abbreviations: ORF, orthosis with joints providing resistive force; LSO, lumbosacral orthosis.
Figure 3 Experimental conditions.

Experimental setup

Static standing was recorded with a three-dimensional (3D) motion capture system (Vicon 612, Vicon, Oxford, UK) that employed two force plates (AMTI, Watertown, MA, USA), 12 infrared cameras (sampling rate, 120 Hz), and 13 infrared-reflective markers (diameter, 14 mm) attached to the C7 spinous process, T12 spinous process, L5 spinous process, manubrium sterni, second sacral vertebra and bilateral acromion process, bilateral anterior and posterior superior iliac spine, and bilateral iliac crest (). All markers were captured in a reference static standing position, and then, the bilateral anterior superior iliac spine and iliac crest markers were removed before initiating measurements because they interfered with wearing of the orthoses. The positions of these removed markers were then interpolated using the reference static trial. To measure low-back muscle activity during static standing, electromyograms employing active electrodes to decrease noise (Biometrics, Newport, UK) were obtained for bilateral ES (2 cm to the side between L4 and L5 vertebrae),Citation15 left IO (2 cm below the anterior superior iliac spine [ASIS] aligned approximately 6° from the line between bilateral ASIS),Citation16 and right GM (2.5 cm below the line between the iliac crest and greater trochanter)Citation17 (). The target muscle to confirm the effect of the ORF orthosis was the bilateral ES. The IO is classified as a core abdominal muscle, and Rostami et alCitation10 reported that IO volume decreased after long-term use of a corset. Also, hip abduction moment increased when elderly subjects wore the ORF while level walking in our previous study.Citation12 Thus, unilateral IO and GM activities were included as supplementary measures in this study.

Figure 4 Positions of reflective markers and electrodes for electromyogram recording.

Notes: (A) Anterior surface, (B) posterior surface, (C) lateral surface.
Figure 4 Positions of reflective markers and electrodes for electromyogram recording.

Electromyography (EMG) signals were measured at 1,080 Hz because the acquisition frequency should be a whole-number multiple of the sampling frequency of the Vicon system (Vicon) (120 Hz).

Data analysis

All signals, including marker displacements and analog EMG signals, were acquired by the Vicon Datastation (Vicon) and then synchronized by correcting for the difference in sampling frequency (120 vs 1,080 Hz) using Vicon Workstation software (Vicon). Band pass filter (20–420 Hz) was used during acquisition to decrease noise,Citation18 and the data were then imported into Visual 3D analytical software (C-motion, Inc., Germantown, MD, USA) for kinetic and kinematic data analysis. Electromyograms were normalized to individual MVCs during isometric contraction (%MVC). Root mean squares (RMS) for a 50 ms window were calculated, and integral values for these muscles (IEMG) were calculated. Consequently, EquationEquation 1 is given as follows:

IEMG=0t[EMGRMS](t)dt(1)
where EMGRMS denotes EMG after conducting RMS for a 50 ms window and t denotes 10 seconds, indicating the end time of static standing.

The physical coordinates and ground reaction force data were low-pass filtered with a second-order recursive Butterworth filter (cutoff frequencies 6 and 18 Hz, respectively) according to Winter’s technique.Citation19 Also, the link segment model consisted of a trunk segment and a pelvis segment, and markers on each segment were used to calculate 3D trunk and pelvic angles using coordinate systems and the Eulerian method.

Center of pressure (COP) displacements are commonly used to evaluate balance performance in the elderly,Citation20 and COP path length was validated as a performance outcome measure in a large group study.Citation21 We therefore calculated COP path length to evaluate balance in the elderly subjects. The COP of the force vector of bilateral feet and COP total trajectory length were calculated for 10 seconds of standing.

Statistical analysis

Average kinetic, kinematic, and EMG values, as well as IEMG were acquired for 10 seconds of static standing. Mean average values of 3D trunk and pelvic angles, average EMG, and IEMG were calculated from two trials, per condition for analysis. Variables were compared by repeated measures analysis of variance (RT-ANOVA) followed by multiple pair-wise comparisons to Bonferroni correction. Statistical analysis was performed with SPSS20 (SPSS Inc., Chicago, IL, USA). Statistical significance was set at P<0.05.

Results

Average pelvis forward tilt angle, thorax extension angle, and thorax angle on the pelvis coordinate system are shown in for the three static standing conditions: no orthosis, ORF, and LSO. One-way RT-ANOVA revealed a significant main effect of condition for all three angles. Pelvis forward tilt angle tended to increase while wearing the ORF and decrease while wearing the LSO, but these results were not significant compared to those without an orthosis. Thorax extension angle and thorax angle on the pelvis coordinate system were significantly increased while wearing the ORF compared to the other two conditions.

Table 1 Mean and standard deviation for kinematic parameters in three standing conditions (N=15) and results of statistical analysis

Integral and average muscular activities are shown in . One-way RT-ANOVA indicated significant main effect of condition on integral and average muscular activities of the bilateral ES and left IO, but not on the GM. Integral and average muscular activities of the bilateral ES were significantly smaller while wearing the ORF compared to no orthosis. For the left ES, integral and average muscular activities were significantly less while wearing the ORF compared to the LSO. The same trend was seen for the right ES, but it was not significant. Integral and average muscular activities of the left IO were significantly dimished while wearing the LSO compared to no orthosis, but there was no significant difference between ORF and no orthosis conditions.

Table 2 Mean and standard deviation for muscular activities in three standing conditions (N=15) and results of statistical analysis

COP trajectory is shown in . No significant difference was observed among the three conditions.

Table 3 Mean and standard deviation for COP trajectory in three standing conditions (N=15) and results of statistical analysis

Discussion

Incidence of LBP increases with age.Citation22 Age-related spinal deformity as well as ES hyperactivity are among the major causes of LBP.Citation18 We previously developed the ORF to modify trunk and pelvis alignment and decrease ES activity. We examined the effects of this orthosis on healthy elderly participants and found that the ORF could effectively modify trunk alignment while decreasing ES activity compared to an LSO or no orthosis. In fact, no significant positive effects were observed while wearing the LSO.

Coskun Benlidayi and BasaranCitation23 reported that lumbar lordosis is significantly smaller in elderly than in young subjects. Wearing of the ORF in this study significantly extended the upper trunk and tended to tilt the pelvis forward, which would contribute to increasing lumbar lordosis. Lee et alCitation13 reported the effectiveness of a lumbar belt and pelvic belt to modify pelvic and spinal alignment on posture in healthy young participants. Additionally, Piffer et alCitation6 reported that use of the newly designed Spinomed® (medi GmbH & Co. KG) orthosis for 6 months improved kyphosis in elderly patients with osteoporosis. However, the present study appears to be the first to report on an orthosis that can modify alignment in healthy elderly participants without spinal deformity or chronic LBP.

Most spinal orthoses were developed to treat LBP and abnormal spinal alignment. Based on the findings of this study, the ORF shows promise for the modification of spinal alignment in elderly people without any specific deformity or syndromes related to LBP. Previous studies reported that interventions teaching awareness of posture, such as lessons on the Alexander technique, could be beneficial in treating LBP, as well as cost-effective.Citation24,Citation25 Back school programs that include exercise therapy could also be effective in elderly people with chronic LBP with no specific spinal deformities.Citation8 Therefore, the ORF’s ability to modify trunk alignment in elderly people might be useful to increase awareness of proper posture and help prevent misalignment and spinal deformity.

The most significant effect of wearing the ORF in this study was to decrease ES activity. A systematic review reported that wearing an LSO alone could not decrease low-back load.Citation9 However, Cholewicki et alCitation18 reported that wearing an LSO could decrease ES activity during a postural control task such as sitting on an unstable seat. In this study, ES activity decreased slightly by 1%–2% MVC while wearing the ORF. Despite this small decrease, a modeling study showed that adding a 32 kg mass to the trunk required an increase in trunk muscle cocontraction of approximately 1%–2% MVC above the level normally necessary to maintain a stable upright position of the spine around the neutral posture.Citation26 Furthermore, previous studies have reported that maintaining muscular contraction above 5% MVC may cause back-muscle fatigue and pain.Citation27 In the present study, average right ES activity was below 5% MVC while wearing the ORF, but was higher for the other two conditions. In addition, average left ES activity decreased within the 6% MVC range while wearing the ORF, but was approximately 8% for the other two conditions. These results indicate that the ORF was effective in decreasing the activity of low-back muscles, which was not observed while wearing the LSO. In a postural control task, trunk muscle activity does not usually exceed 3% MVC in young participants.Citation27 However, muscular activity of elderly people during MVC is lower, and therefore greater relative effort would be needed to maintain an upright standing position. Rostami et alCitation10 reported that wearing an LSO led to decreased muscle volume in the abdominal side muscles, including the IO. Wearing the ORF in the present study did not significantly decrease IO activity, whereas wearing the LSO significantly decreased it, compared to no orthosis. These results support those of Rostami et alCitation10 and suggest that resistive force might not decrease low-back muscle activity without a decrease in side abdominal muscle volume.

No significant changes in COP trajectory were observed while wearing either orthosis in this study. Cholewicki et alCitation18 reported that COP displacement during an unstable sitting task did not significantly differ from the control condition (no orthosis) while wearing an LSO. Furthermore, Chen et alCitation28 reported that their insole served to improve the stability index, as calculated using COP displacement in elderly participants. COP is mainly controlled by the ankle plantar flexors, and therefore intervention using foot-based orthotic devices may be more useful than trunk-based devices.

Wearing the ORF during static standing served to decrease ES activity and modify trunk alignment, which may be effective for the prevention and treatment of LBP and spinal deformity in elderly people. However, this study has several limitations. First, we did not confirm the effects of long-term ORF use, as wearing the ORF or LSO for lengthy periods might adversely affect muscle control. Second, participants were healthy elderly men only and this was a within-subject trial. Healthy elderly women and participants with LBP or low-back disorders should be included in future studies, including randomized controlled trials. Third, we confirmed reduction of ES activity, but it might not be the exact cause. Resistive moment generated by the ORF joints may have decreased extension moment exerted by the ES muscles, or greater thorax extension angle could have decreased ES activity by reducing the lever arm from the L4/L5 joint to gravitational force on the center of gravity of the upper trunk. Moreover, ES is a surface muscle. In a future study, we must confirm these changes in spinal loading using a more detailed biomechanical model including the deep back muscles, such as bilateral multifidus muscle.

Conclusion

This study revealed that the ORF significantly improved trunk alignment and decreased ES activity in healthy elderly participants. These findings suggest that the ORF may help prevent LBP and spinal deformity in elderly people. Further studies are needed to examine the use of the ORF in patients with LBP and spine deformity.

Author contributions

Provided substantial contribution to conception and design: JK, KM, TY. Involved with data collection and analysis: JK, SI, AI. Involved with interpretation of data: JK, SI, AI. Drafted the article: JK, KM. Revised the manuscript critically for important intellectual content: JK, KM, TY, SI, AI. Provided approval of the version to be published: JK, KM, TY, SI, AI.

Acknowledgments

This study was supported by the dissemination project of Clinical Research for Occupational Injuries and Illness from Ministry of Health, Labour and Welfare of Japan.

Disclosure

The authors report no conflicts of interest in this work.

References

  • GelbDELenkeLGBridwellKHBlankeKMcEneryKWAn analysis of sagittal spinal alignment in 100 asymptomatic middle and older aged volunteersSpine199520135113587676332
  • NguyenTSambrookPKellyPPrediction of osteoporotic fractures by postural instability and bone densityBMJ1993307111111158251809
  • KasukawaYMiyakoshiNHongoMRelationships between falls, spinal curvature, spinal mobility and back extensor strength in elderly peopleJ Bone Miner Metab201028828719690799
  • BattagliaGBellafioreMCaramazzaGPaoliABiancoAPalmaAChanges in spinal range of motion after a flexibility training program in elderly womenClin Interv Aging2014965366024748783
  • ImagamaSMatsuyamaYHasegawaYBack muscle strength and spinal mobility are predictors of quality of life in middle-aged and elderly malesEur Spine J20112095496121072545
  • PfeiferMKohlweyLBegerowBMinneHWEffects of two newly developed spinal orthoses on trunk muscle strength, posture, and quality-of-life in women with postmenopausal osteoporosis: a randomized trialAm J Phys Med Rehabil20119080581521681065
  • IshidaHWatanabeSYanagawaHKawasakiMKobayashiYAmanoYImmediate effects of a rucksack type orthosis on the elderly with decreased lumbar lordosis during standing and walkingElectromyogr Clin Neurophysiol200848536118338535
  • CostantinoCRomitiDEffectiveness of Back School program versus hydrotherapy in elderly patients with chronic non-specific low back pain: a randomized clinical trialActa Biomed201485526125265444
  • van DuijvenbodeIJellemaPvan PoppelMvan TulderMWLumbar supports for prevention and treatment of low back painCochrane Database Syst Rev2008Cd00182318425875
  • RostamiMNoormohammadpourPSadeghianAHMansourniaMAKordiRThe effect of lumbar support on the ultrasound measurements of trunk muscles: a single-blinded randomized controlled trialPM R20146302308 quiz 30824107427
  • KatsuhiraJMiuraNYasuiTTakaneMSumikoYEfficacy of a newly designed trunk orthosis with joints providing resistive force in adults with post-stroke hemiparesisProsthet Orthot Int Epub8182014
  • IijimaSKatsuhiraJItoANomuraTMaruyamaHEffects of a trunk brace with joints that provides a resistive force to modify pelvic alignment during level walking in the elderlyPhys Ther Japan201441355363
  • LeeESKoCWSuhSWKumarSKangIKYangJHThe effect of age on sagittal plane profile of the lumbar spine according to standing, supine, and various sitting positionsJ Orthop Surg Res201491124571953
  • MontgomeryJHislopHConnellyBDaniels and Worthingham’s Muscle Testing: Techniques of Manual Examination8th edMaryland Heights, MOSaunders/Elsevier2007
  • De FoaJLForrestWBiedermannHMuscle fibre direction of longissimus, iliocostalis and multifidus: landmark-derived reference linesJ Anat19891632432606776
  • NgJKKippersVRichardsonCAMuscle fibre orientation of abdominal muscles and suggested surface EMG electrode positionsElectromyogr Clin Neurophysiol19983851589532434
  • PerottoADelagiEFIazzettiJMorrisonDAnatomical Guide for The Electromyographer: The Limbs and TrunkSpringfield, ILCharles C Thomas2005
  • CholewickiJReevesNPEverdingVQMorrisetteDCLumbosacral orthoses reduce trunk muscle activity in a postural control taskJ Biomech2007401731173617054963
  • WinterDABiomechanics and Motor Control of Human MovementHoboken, NJJohn Wiley & Sons2009
  • KalischTKattenstrothJCNothSTegenthoffMDinseHRRapid assessment of age-related differences in standing balanceJ Aging Res2011201116049021629742
  • DonathLRothRZahnerLFaudeOTesting single and double limb standing balance performance: comparison of COP path length evaluation between two devicesGait Posture20123643944322565319
  • DunnKMHestbaekLCassidyJDLow back pain across the life courseBest Pract Res Clin Rheumatol20132759160024315141
  • Coskun BenlidayiIBasaranSComparative study of lumbosacral alignment in elderly versus young adults: data on patients with low back painAging Clin Exp Res20152729730225286900
  • LittlePLewithGWebleyFRandomised controlled trial of Alexander technique lessons, exercise, and massage (ATEAM) for chronic and recurrent back painBMJ2008337a88418713809
  • HollinghurstSSharpDBallardKRandomised controlled trial of Alexander technique lessons, exercise, and massage (ATEAM) for chronic and recurrent back pain: economic evaluationBMJ2008337a265619074232
  • CholewickiJPanjabiMMKhachatryanAStabilizing function of trunk flexor-extensor muscles around a neutral spine postureSpine199722220722129346140
  • BjorkstenMJonssonBEndurance limit of force in long-term intermittent static contractionsScand J Work Environ Health197732327847427
  • ChenTHChouLWTsaiMWLoMJKaoMJEffectiveness of a heel cup with an arch support insole on the standing balance of the elderlyClin Interv Aging2014935135624600215