88
Views
6
CrossRef citations to date
0
Altmetric
Case Series

Wound management with vacuum-assisted closure in postoperative infections after surgery for spinal stenosis

, &
Pages 7-11 | Published online: 22 Dec 2014

Abstract

Objective

To evaluate the results of negative-pressure wound therapy (NPWT) in the treatment of surgical spinal site infections.

Materials and methods

The use of NPWT in postoperative infections after dorsal spinal surgery (transforaminal lumbar interbody fusion plus posterior instrumentation) was studied retrospectively. From February 2011 to January 2012, six patients (females) out of 317 (209 females; 108 males) were readmitted to our clinic with surgical site infections on postoperative day 14 (range 9–19) and were treated with debridement, NPWT, and antibiotics. We evaluated the clinical and laboratory data, including the ability to retain the spinal hardware and recurrent infections.

Results

The incidence of deep postoperative surgical site infection was six (1.89%) patients (females) out of 317 patients (209 females; 108 males) at 1 year. All patients completed their wound NPWT regimen successfully. An average of 5.1 (range 3–8) irrigation and debridement sessions was performed before definitive wound closure. The mean follow-up period was 13 (range 12–16) months. No patient had a persistent infection requiring partial or total hardware removal. The hospital stay infection parameters normalized within an average of 4.6 weeks.

Conclusion

The study illustrates the usefulness of NPWT as an effective adjuvant treatment option for managing complicated deep spinal surgical wound infections.

Introduction

Postoperative wound infection after spinal surgery is a serious though uncommon problem, which still occurs despite the use of prophylactic antibiotics and advances in surgical techniques and postoperative care.Citation1 Infection of the spine after instrumentation is a challenge for the spinal surgeon. The cumulative incidence of postoperative spinal wound infections was found to be 0.6% for minimally invasive transforaminal lumbar interbody fusion (TLIF) and 4.0% for “open” TLIF.Citation2 According to a National Nosocomial Infection Surveillance report, several factors increase the rate of postoperative infections in common procedures, such as spinal fusions and laminectomies.Citation3 Instrumentation increases the rate of infection, as do malnutrition, an extended preoperative hospital stay, and increased blood loss.Citation4

Various treatment protocols for debridement, soft-tissue management, and antibiotic therapy have been recommended, but these have had mixed results. The use of Vacuum-Assisted Closure® (VAC®; Kinetic Concepts, San Antonio, TX, USA), a type of negative-pressure wound therapy (NPWT), in wound therapy has gained popularity for the management of acute, subacute, and chronic wounds. By exposing the wound bed to controlled negative pressure, wound therapy removes edema fluid, increases blood flow, decreases the bacterial load, and stimulates the proliferation of reparative granulation tissue. The NPWT system also assists the debridement of necrotic tissue and acts as a sterile barrier. It has been used successfully to treat open wounds of the extremities, thoracic and abdominal walls, and pressure or diabetic ulcers.Citation5,Citation6

This retrospective study reports six patients in whom NPWT was used as a new approach to treat deep subfascial infections after dorsal spinal surgery based on temporary soft tissue coverage with a reduction in the dead space and delayed primary wound closure, without removing the implants.

Patients and methods

From February 2011 to January 2012, TLIF and posterior instrumentation were performed in 317 patients (209 females; 108 males) at our clinic. Cancellous chip allografts were used to fuse the arthrodesis site. All instrumentation used was made of titanium (Teknomed Spinal instrumentation Systems, Izmir, Turkey). Six of 317 patients were admitted to our clinic approximately 2 weeks after spinal surgery, with early surgical site infections and exposed instrumentation. The infected wounds were in the lumbar region. The risk factors, comorbidities, previous spinal surgery, preoperative admission history, and medical records of the six patients were reviewed. The laboratory evaluation included infection markers, such as the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and white blood cell (WBC) count. The infection sites of the six patients were also evaluated with magnetic resonance imaging (MRI) if there were any signs of osteomyelitis.

After completing the clinical, laboratory, and radiological evaluations, the six patients were treated with serial debridement and NPWT (). The VAC® system was applied, and intraoperative cultures were obtained at the first debridement session. The intraoperative debridement involved thorough lavage and the removal of all macroscopic contamination, devitalized tissue, and allograft bone (). After cultures were obtained, parenteral antibiotic treatment was administered for at least 4 weeks, and oral sulfamethoxazole and trimethoprim (800 mg and 160 mg, respectively) 1–2 times a day was continued for at least 1 month further after hospital discharge. The wounds were treated with a negative pressure of 100 mmHg, applied continuously. The VAC®+ dressings were changed at 3-day intervals until granulation tissue formed, under sedoanalgesia and sterile conditions in the operating room. When there was no drainage from the wound, we closed the wound in anatomical layers.

Figure 1 Pre-VAC spinal wound (A); after application of the VAC device (B).

Abbreviation: VAC, vacuum-assisted closure.
Figure 1 Pre-VAC spinal wound (A); after application of the VAC device (B).

Figure 2 After surgical debridement and before VAC application.

Abbreviation: VAC, vacuum-assisted closure.
Figure 2 After surgical debridement and before VAC application.

All of the patients were evaluated for eradication of infection, using clinical, radiological, and laboratory indicators, such as the presence of spinal pseudarthrosis, ESR, CRP level, WBC count, wound culture negativity, and need for additional surgery after application of the VAC® system. All patients were evaluated for a minimum of 6 months after definitive closure of the subfascial wound infection.

Results

Of the TLIF patients, 65.9% were female, and all of the patients with surgical site infections were female. At our clinic, the incidence of surgical spinal infection after open TLIF and posterior instrumentation was 1.89%. The mean age of the infected patients was 55.6 (range 49–62) years. Comorbidities included diabetes, chronic renal failure, alcohol abuse, obesity, malnutrition, rheumatoid arthritis, and smoking. All patients underwent the same procedure (TLIF plus posterior fusion with instrumentation) in the lumbar spinal region as the index operation (). A combination of superficial and deep drains was used in the primary procedure in all cases. The average surgery time was 2.1 (range 1.8–3) hours. The infection presented a mean of 14 days after surgery. Overall, an average of 5.1 (range 3–8) debridement and irrigation procedures was performed before the definitive wound closure operation. The average time of previous spinal surgery to first revision surgery was 14 (range 9–19) days and VAC® duration of patients was 15.5 (range 9–24) days. The average follow-up of the infected patients was 13 (12–16) months.

Table 1 Baseline patient characteristics

All patients were started on parenteral ampicillin/sulbactam (1 g), and received one to four doses as empirical broad-spectrum antibiotic therapy until culture results and antibiograms were available; then, the treatment was changed to a more specific antibiotic. Culture specimens from all patients were positive for methicillin-resistant Staphylococcus aureus (MRSA). Therefore, ampicillin/sulbactam therapy was stopped and parental teicoplanin therapy was started, at 400 mg twice daily as the initial dosage and continued at 400 mg once a day after the second day. The average duration of parenteral antibiotic therapy was 6.6 (range 5–8) weeks. Culture negativity and normalization of laboratory markers occurred at an average of 4.6 (range 3–6) weeks. All patients achieved clean closed wounds with retention of the instrumentation. At 2 months after the first debridement, follow-up MRI showed no signs of infection radiologically. The mean follow-up period was 13 (range 12–16) months.

Discussion

First of all, we evaluated this situation as hospital-acquired infections. So, we developed a multidisciplinary clinical approach, and our sterilization program and infection control protocols were reviewed.

We now believe that preoperative patients should be tested with nasal and rectal swabs, and if they are positive, they could be pretreated with oral preoperative antibiotics that would provide better MRSA coverage. This may lessen the chance of infection. Also, education is key to infection prevention. Experienced nurses, such as nurse practitioners, clinicians, or preceptors, should be diligent in teaching new nurses about hand hygiene, gloving, sterile techniques, and high-risk patients.

In our experience, NPWT is a useful tool in the complex management of deep infections in spinal wounds. Although we had some success treating patients with the NPWT device, the number of patients in this retrospective review was too small and the follow-up period too short to thoroughly evaluate the effectiveness of the NPWT system.

The reported rate of spinal infection increases with the complexity of the procedure, ranging between 0.6% and 4%.Citation2 The added benefit of the NPWT device over simple irrigation, debridement, and open-wound treatment is the effect of continuous negative pressure on wound healing (ie, fluid removal, increased circulation, and granulation tissue regeneration).Citation7

In most studies, the NPWT dressing was placed after debridement and irrigation of the wound.Citation8Citation10 Yuan-Innes et al reported the successful use of NPWT in two patients with infected and exposed spinal hardware.Citation11 Mehbod et alCitation12 described 20 cases in which NPWT was used in the management of deep wound infections occurring after spinal fusion procedures and reported clean closed wounds without hardware removal in all cases.Citation12 In their series, approximately 2.2 (range 2–3) procedures were required until definitive closure, which occurred on average 7 (range 5–14) days after the initial placement. Our patients needed more debridement sessions and a much longer NPWT duration until wound closure than was reported by Mehbod et al.Citation12 The difference might have resulted from our aggressive treatment strategy.

Lehner et alCitation13 reported results of the treatment of infected orthopedic implants with NPWT, with instillation in 32 patients treated after a diagnosis of early or late implant infection.Citation13 In that multicenter, prospective, nonrandomized study, 86.4% of the patients with acute implant infections and 80% with chronic infections were treated successfully. The mean duration of NPWT was 16.3 days. Our results are consistent with theirs, but our NPWT system did not have an instillation option.

Other articles reporting case series, and individual cases have addressed potential complications associated with NPWT use, although none of these articles has appeared in the spine literature. Clinicians generally mention the risk of pain due to the sponge volume and negative pressure, the growth of granulation tissue into the sponge, possible minor bleeding at dressing changes, odor, and skin erosion around the suction tube.Citation14Citation16 No complications developed in our cases.

In our opinion, the key component of the successful treatment of infections after dorsal spine surgery is operative management with repeated second-look operations and copious debridement. We do not use a local irrigation system for infected wounds because we believe that these systems limit the irrigation to a small part of the wound. As a technique for reducing the dead space and conditioning the wound, the NPWT dressing has important merits: the temporary closure prevents contamination and desiccation of the wound and protects it from injury.

In summary, an NPWT system is an effective adjunct in closing postoperatively infected spinal wounds and reduces the need for hardware removal during treatment. Infections caused by multiple bacterial species or MRSA are more likely to need repeat debridement and NPWT.

Disclosure

The authors report no conflicts of interest in this work.

References

  • WeinsteinMAMcCabeJPCammisaFPPostoperative spinal wound infection: a review of 2,391 consecutive index proceduresJ Spinal Disord200013542242611052352
  • ParkerSLAdogwaOWithamTFAaronsonOSChengJMcGirtMJPost-operative infection after minimally invasive versus open transforaminal lumbar interbody fusion (TLIF): literature review and cost analysisMinim Invasive Neurosurg2011541333721506066
  • National Nosocomial Infections Surveillance SystemNational Nosocomial Infections Surveillance (NNIS) System Report, data summary from January 1992 through June 2004, issued October 2004Am J Infect Control200432847048515573054
  • BeinerJMGrauerJKwonBKVaccaroARPostoperative wound infections of the spineNeurosurg Focus2003153E1415347232
  • SchollLChangEReitzBChangJSternal osteomyelitis: use of vacuum-assisted closure device as an adjunct to definitive closure with sternectomy and muscle flap reconstructionJ Card Surg200419545346115383060
  • CothrenCCMooreEEJohnsonJLMooreJBBurchJMOne hundred percent fascial approximation with sequential abdominal closure of the open abdomenAm J Surg2006192223824216860637
  • OuseyKJAtkinsonRAWilliamsonJBLuiSNegative pressure wound therapy (NPWT) for spinal wounds: a systematic reviewSpine J201313101393140523981819
  • VicarioCde JuanJEsclarinAAlcobendasMTreatment of deep wound infections after spinal fusion with a vacuum-assisted device in patients with spinal cord injuryActa Orthop Belg200773110210617441666
  • PloumisAMehbodAADresselTDDykesDCTransfeldtEELonsteinJETherapy of spinal wound infections using vacuum-assisted wound closure: risk factors leading to resistance to treatmentJ Spinal Disord Tech200821532032318600140
  • VikatmaaPJuutilainenVKuukasjärviPMalmivaaraANegative pressure wound therapy: a systematic review on effectiveness and safetyEur J Vasc Endovasc Surg200836443844818675559
  • Yuan-InnesMJTempleCLLaceyMSVacuum-assisted wound closure: a new approach to spinal wounds with exposed hardwareSpine (Phila Pa 1976)2001263E30E3311224876
  • MehbodAAOgilvieJWPintoMRPostoperative deep wound infections in adults after spinal fusion: management with vacuum-assisted wound closureJ Spinal Disord Tech2005181141715687846
  • LehnerBFleischmannWBeckerRJukemaGNFirst experiences with negative pressure wound therapy and instillation in the treatment of infected orthopaedic implants: a clinical observational studyInt Orthop20113591415142021584643
  • ArgentaLCMorykwasMJVacuum-assisted closure: a new method for wound control and treatment: clinical experienceAnn Plast Surg1997386563576 discussion 5779188971
  • DeFranzoAJArgentaLCMarksMWThe use of vacuum-assisted closure therapy for the treatment of lower-extremity wounds with exposed bonePlast Reconstr Surg200110851184119111604617
  • MasdenDGoldsteinJEndaraMXuKSteinbergJAttingerCNegative pressure wound therapy for at-risk surgical closures in patients with multiple comorbidities: a prospective randomized controlled studyAnn Surg201225561043104722549748