Patients’ perspectives and preferences in the choice of inhalers: the case for Respimat® or HandiHaler®

, &
Pages 1561-1572 | Published online: 18 Aug 2016

Abstract

Poor inhaler technique hampers the efficacy of drug therapy in asthma and chronic obstructive pulmonary disease. Not only does this affect individual patient care, but it also impacts on the wider health care economics associated with these conditions. Treatment guidelines recommend a systematic approach to drug class selection; however, standardization of inhaler selection is currently difficult owing to the complexity of the interaction between the inhaler device and the patient. Specifically, individual patient preference can influence how successful a treatment is overall. This article reviews inhaler devices from the patient perspective, with a particular focus on the dry powder inhaler HandiHaler® and Respimat® Soft Mist™ Inhaler. It discusses factors that influence device preference and treatment compliance and reviews tools that can aid health care professionals to better match inhaler devices to individual patients’ needs.

Introduction

Inhaled therapy remains the cornerstone of treatment for pulmonary disorders such as asthma and chronic obstructive pulmonary disease (COPD). It offers advantages over oral tablet administration, such as effective targeting of treatment to the lungs at a lower dose with a rapid onset of action.Citation1Citation5

Despite the introduction of new pharmacological treatments and the availability of a range of different types of inhaler devices,Citation1,Citation2,Citation5 asthma and COPD often remain suboptimally controlled in terms of symptom relief and reduction in exacerbation risk.Citation6,Citation7 Incorrect use of inhaler devices is common – real-world studies estimate that up to 94% of patients do not use their inhalers properly.Citation6,Citation8,Citation9 This can lead to inadequate drug dosing, which, in turn, contributes to a worsening of quality of life and suboptimal disease control.Citation8Citation11

With over 200 different drug–inhaler combinations available,Citation2 matching patient characteristics and preferences to the most appropriate drug treatment and inhaler device remains challenging. Clinical respiratory practice in the majority of patients is to first select the class of medication, followed by the specific agent, and then the inhaler device itself. However, the importance of inhaler selection as part of the treatment decision is becoming increasingly recognized,Citation2,Citation9,Citation12Citation14 and this article proposes that careful consideration of inhaler selection warrants greater priority among prescribers.

This review examines the key considerations for selecting devices most suited to patients’ needs; it also discusses the importance of correct inhaler technique for optimizing treatment outcomes and evaluates patients’ perspectives and preferences when switched from a dry powder inhaler (DPI) to the Respimat® Soft Mist™ Inhaler (SMI; Boehringer Ingelheim International GmbH, Ingelheim am Rhein, Germany).

The case for monitoring inhaler suitability

Treatment guidelines emphasize that good symptom control with inhaled maintenance drugs is fundamental to the management of asthma and COPD.Citation3,Citation4 Nevertheless, guidelines have lacked clarity on specific guidance regarding appropriate inhaler selection for achieving optimum symptom control.Citation2,Citation14 It is encouraging, however, to see that the latest Global Initiative for Asthma and Global Initiative for Chronic Obstructive Lung Disease strategy documents both state the importance of inhaler device selection in day-to-day practice.Citation3,Citation4

It is well established that poor inhalation technique can severely impact the clinical efficacy of medications, resulting in impaired disease control, worsening quality of life, increased exacerbation and mortality risk, increased hospitalizations (), and, in turn, increased health care expenditure.Citation8Citation11 Although incorrect inhaler use may be due, in part, to a patient’s impaired dexterity (particularly with elderly COPD patients), evidence suggests that many patients receive inadequate or no training in the use of their device.Citation2,Citation8,Citation9,Citation15,Citation16 In a systematic literature review of patients evaluated about their use of DPIs for either asthma or COPD, one-quarter of the patients had received no verbal instruction on inhaler technique.Citation8 For those patients who had received instruction, the quality and duration of the instruction and review of technique were considered inadequate.Citation8 Perhaps more concerning are the findings from several studies that many medical and nursing personnel do not have a good understanding of correct inhaler technique, despite their awareness of the importance of correct technique on treatment outcomes.Citation9,Citation15,Citation17Citation19 Educational efforts therefore need to be focused on primary prescribers of inhaler devices so as to limit or avoid the consequences of poor inhaler technique by their patients. Written instruction is known to be ineffective as a training method; verbal instruction, technique assessment, and reassessment are all essential for achieving correct inhaler use.Citation8 Reflecting this need for improved education, a call to action for improving education of inhaler technique at a policy level was published by the International Primary Care Respiratory GroupCitation13 and the Aerosol Drug Management Improvement Team.Citation15

Figure 1 Association between asthma and COPD disease control and at least one critical inhaler error.

Notes: (A) Describes the relationship between risk of at least one critical inhaler error and Asthma Control Test questionnaire score. (B) Describes the relationship between risk of at least one critical inhaler error and self-reporting of some unscheduled health-care resources use in the last year. Data from Melani et al.Citation57
Abbreviation: COPD, chronic obstructive pulmonary disease.
Figure 1 Association between asthma and COPD disease control and at least one critical inhaler error.

A meta-analysis of 59 randomized trials assessing respiratory treatments delivered by a metered dose inhaler (MDI), nebulizer, or DPI has suggested that when inhalers are used correctly, there is little difference in clinical efficacy between devices.Citation20 Although inhaler selection remains an essential component of tailored treatment, the results from this meta-analysis highlight that considerable improvements in disease management are possible by investing in training of correct inhaler use.

Ongoing monitoring of inhaler technique should be an integral component of routine management of COPD and asthma patients. An algorithm proposed by the Aerosol Drug Management Improvement Team gives prescribers a practical tool for assessing whether a change in device type is needed or a step-up in therapy is required ().Citation2,Citation15 Although initially developed for asthma patients, this algorithm could also be adapted for the management of patients with COPD.Citation2

Figure 2 ADMIT asthma therapy adjustment flow chart.

Note: Adapted from from Respir Med, 100/9, Crompton GK, Barnes PJ, Broeders M, et al, The need to improve inhalation technique in Europe: a report from the Aerosol Drug Management Improvement Team, 1479–1494, Copyright 2006, with permission from Elsevier.Citation15
Abbreviation: ADMIT, Aerosol Drug Management Improvement Team.
Figure 2 ADMIT asthma therapy adjustment flow chart.

Overview of handheld inhaler devices

Handheld inhalers are available as either pressurized MDIs (pMDIs), DPIs, or SMI (Respimat®, Boehringer Ingelheim, Germany; currently, the only SMI marketed).Citation5 Nebulizers are beyond the scope of this review; however, the articles by Ibrahim et alCitation21 and Lavorini et alCitation5 provide detailed discussions of nebulizer technology. A description of the currently available handheld devices is provided, and a summary of the advantages and disadvantages of each type is given in .

Table 1 Major components, advantages, and disadvantages of inhaler devices

pMDIs

Introduced in the 1950s,Citation22 pMDIs were the first of the handheld delivery devices. Technological developments in pMDIs have occurred over the past 60 years, but common components of all MDIs are a pressurized canister of drug in solution or suspension, a chamber for producing an aerosol, and a mouthpiece through which the aerosol is inhaled.

Older pMDIs created a high-velocity spray of relatively large droplets.Citation23,Citation24 The change in propellants from chlorofluorocarbon to hydrofluoroalkane has led to a reduced-velocity spray that delivers a smaller particle size. These properties lead to reduced oropharyngeal deposition and improved distribution of drug particles throughout the airways with newer hydrofluoroalkane pMDIs compared with chlorofluorocarbon MDIs.Citation23Citation27

In terms of operational design, two generations of pMDI device now exist in practice. First-generation pMDIs are simple, push-activated, pressure-powered aerosols that require precise coordination and inhalation by the patient. A valve-holding chamber or spacer with a one-way valve allows the aerosol to be inhaled with several intakes and can be added to reduce dependency on coordination. Although spacers are essential for children and those patients with very severe cognitive and physical impairment, they are inconvenient to carry and need to be cleaned between uses.Citation16,Citation28

Second-generation pMDIs require breath actuation rather than push activation to reduce dependency on the patient’s coordination of inhalation and actuation. Currently in development is a new generation of “intelligent” pMDIs that have electronic computation of delivery to compensate for inadequate inhalation and provide more reliable feedback on delivery.Citation29

DPIs

DPIs rely on air drawn through the device to pick up powder from a container and carry it into the lungs within the same airstream.Citation24 Some devices require insertion of drug capsules designed to release all the powdered content into the airstream. Other devices contain multiple doses taken from a reservoir or multiple prefilled blisters/cartridges of drug powder.Citation24 These do not require the user to carry packets of separate drug capsules, but function is otherwise similar to single-capsule devices.

Inhalation flow rate through the device is critical to the successful operation of all DPIs, and the inspiratory effort required to deliver the drug to the lungs depends on the device. Not all patients are capable of creating sufficiently controlled inspiratory effort every time, especially during an exacerbation.Citation30 New DPI devices are beginning to address this important issue, including the dose protector of the NEXThaler® (Chiesi Limited, Manchester, UK), which prevents release of the dose until sufficient flow rate is achieved,Citation31 and the electronic power-assisted DPIs (active DPIs) currently in development.Citation5

Slow-moving SMIs

The SMI was introduced in 2007 by Boehringer Ingelheim as Respimat® SMI. It comprises design elements from the pMDI, but was designed to solve some disadvantages associated with pMDIs and DPIs, such as deposition of drug in the oropharynx.Citation32 Respimat® uses spring power (rather than a pressurized container) to generate a low-velocity vapor cloud into the mouth from a liquid formulation of the drug, which is pushed through a specially designed nozzle. The mist generation is sustained for approximately 1.5 seconds but still requires a degree of coordination of inhalation and actuation (although less so than for pMDIs).Citation32 Compared with pMDI devices, lung deposition with Respimat® is up to 50% higher and oropharyngeal deposition is lower.Citation5 Typical scintigraphic images for Respimat® (Boehringer Ingelheim), Turbuhaler® (AstraZeneca, Lund, Sweden) DPI at slow and fast inhaled flow rates, and pMDI devicesCitation32,Citation33 are shown in . Respimat® also has the benefit of a dose indicator that provides the user with an estimate of doses remaining in the cartridge.

Figure 3 Typical scintigraphic images for Respimat®, Turbuhaler® DPI at slow and fast inhaled flow rates, and pMDI.

Notes: (A) Respimat® SMI; (B) Turbuhaler® DPI – slow; (C) Turbuhaler® DPI – fast; (D) pMDI. Reproduced from Pitcairn G, Reader S, Pavia D, Newman S. Deposition of corticosteroid aerosol in the human lung by Respimat Soft Mist inhaler compared to deposition by metered dose inhaler or by Turbuhaler dry powder inhaler. J Aerosol Med. 2005;18(3):264–272.Citation33 The publisher for this copyrighted material is Mary Ann Liebert, Inc. publishers.
Abbreviations: DPI, dry powder inhaler; pMDI, pressurized metered dose inhaler; SMI, Soft Mist™ Inhaler.
Figure 3 Typical scintigraphic images for Respimat®, Turbuhaler® DPI at slow and fast inhaled flow rates, and pMDI.

Inhaler techniques

Each type of device requires a different inhalation technique to achieve optimal drug delivery to the lungs (). Furthermore, specific instructions vary between devices. This can cause confusion among patientsCitation34 and highlights why the prescription of multiple inhaler types to one patient, or switching to different inhaler types, requires careful management and discussion with the patient.

Table 2 Correct techniques for using pMDI, DPI (specifically HandiHaler®), and SMI (Respimat®) devices

Requirements of the “ideal” inhaler

Characteristics of inhaler devices that affect patients’ perceptions of their COPD therapy include perceived efficacy, ease and convenience of use, how they will feel about using the device in public, their physician’s preference, availability of the drug or device preparations, loyalty to the brand of inhaler, cost, time it takes to learn how to use the device, device appearance (size, weight, etc), how to clean the device, and disposability/environmental issues.Citation35 The ideal inhaler would be small and breath-activated; it would also deliver flow-independent drug deposition in the lung and be suitable for use in patients who have low inspiratory airflow.Citation36 It should be lightweight and require no accessories, external assistance, or power source to enable its use. In addition, it should have the capability to count the number of delivered and/or residual doses; not allow degradation of the active ingredient; contain no additives, propellants, or excipients; and be able to quickly aerosolize the drug.Citation37

The following are some of the factors associated with inhaler design and use that can influence how patients interact with their inhalers.

Aerosolizing

Conversion of the drug from a compacted to an inhalable form requires energy, which is either stored within the device (eg, pressurized canister, electronics, or spring) or provided by the airflow from the inhalation process. Drug delivery is affected by the inspiratory flow rate required to generate drug particles of a suitable size for inhalation (eg, 1–5.8 µm) and the fine particle fraction of the aerosol (defined as particles ≤5.8 µm).Citation32,Citation38 These factors vary between inhaler devices ().

Aerosolizing by pMDIs and the SMI is less dependent on patient inspiratory effort than for DPIs that require a high inspiratory flow rate to ensure correct inhalation and deposition of the drug into the lungs.Citation22 This has advantages for patients with impaired lung function. However, inspiratory flow rates vary between DPIs, depending on the internal resistance of the device, eg, the HandiHaler® (Boehringer Ingelheim International GmbH) is a flow-limiting device, with target flow between 20–30 L/min, compared with reported mean flow rates of 82 mL for the Turbuhaler® DPI (AstraZeneca) and 117 mL for the Diskhaler® DPI (GlaxoSmithKline plc, London, UK; reflecting higher internal resistance).Citation39 To produce fine aerosol particles that are inhalable and maximize drug deposition in the lung,Citation32,Citation38 the target minimum inspiratory flow rates are <50 L/min for a high-resistance DPI, compared with 50–60 mL for a medium-resistance DPI and 90 L/min for a low-resistance DPI.Citation5

Inhaler design also affects the extent to which the aerosol contains fine particles. A high fine particle fraction allows more of the drug dose to be deposited in the lung, rather than in the oropharynx.Citation32 It has been shown that the fine particle fraction of the aerosol generated using the SMI is approximately 75%, which is more than twice the value reported for pMDIs or DPIs.Citation38 However, other new generation inhalers, such as the NEXThaler® DPI (Chiesi Limited), have evolved to deliver extrafine drug particles that can increase drug deposition throughout the bronchial tree.Citation5,Citation40

All methods of aerosolizing require the use of carriers and excipients, whether they are gaseous, liquid, or solid. Although they are pharmacologically inert, they can produce a cold sensation that may cause the patient to stop inhaling.Citation24 SMIs do not require propellants,Citation41 and excipients are minimized. The delivery of the drug as a mist aerosol avoids the cool sensation from evaporating gases that can be experienced with pMDIs.Citation16 This may be beneficial for some patients.

Delivery

After the patient aerosolizes the drug into their mouth, their inhalation flow must carry the aerosolized drug into the lungs – a process highly influenced by the patient. Failure of the drug to be effectively delivered into the lungs can result in a diminished dose as well as the potential for local side effects (eg, sore throat) from oropharyngeal deposition of the drug.Citation42,Citation43 In addition, drug deposited in the oropharynx may be swallowed, leading to gastrointestinal absorption, which may contribute to systemic side effects. Ideally, drug reaching the lungs is targeted to the airways, where bronchodilatory and/or anti-inflammatory effects will provide the greatest benefit, with minimal alveolar deposition, since this is the main site of systemic absorption in the lungs.Citation44

Advancements in inhaler design have greatly improved drug delivery and have allowed lower nominal doses of drug to be used to achieve control in asthma and COPD, thus minimizing the risk of overdosing.Citation33 For example, the SMI Respimat® delivers a slow-moving spray cloud that is of a longer duration and smaller droplet size than the spray from a pMDI, which results in deposition of a higher proportion of the drug in the lungs compared with pMDIs and some DPIs.Citation33

Dependability

Frequent cleaning of devices is often necessaryCitation16 since the drug can be deposited on the device and accumulation is inevitable. Nozzles can easily become blocked without regular maintenance. Microbial contamination is also possible within inhalers and spacer devices.Citation45,Citation46 Cleaning regimens must be as simple as possible to encourage compliance with this important component of inhaler use and to ensure operational reliability of the device.

Perceived efficacy of an inhaler is an important factor influencing patients’ device preferences.Citation35 Reassurance from device feedback interfaces such as dose counters has been shown to be important in improving treatment adherence, reminding patients when to replace cartridges, and preventing patients from using their inhalers beyond the recommended number of doses.Citation5,Citation11

Matching inhalers to the patient’s physical ability

The authors of this review and others have previously proposed an algorithm for the selection of a particular inhaler device based on the patient’s physical abilities ().Citation12 The algorithm considers three questions: 1) Is the patient capable of conscious inhalation? 2) Is the patient likely to reliably generate and control sufficient inspiratory flow? 3) Is the patient capable of hand–inhalation coordination?

Figure 4 Algorithm for choosing inhaler device according to the patient’s inspiratory flow and ability to coordinate inhaler actuation and inspiration.

Note: Reprinted from Respir Med, 107/12, Dekhuijzen PN, Vincken W, Virchow JC, et al, Prescription of inhalers in asthma and COPD: towards a rational, rapid and effective approach, 1817–1821, Copyright 2013, with permission from Elsevier.Citation12
Abbreviations: BA-pMDI, breath-actuated pressurized metered dose inhaler; DPI, dry powder inhaler; pMDI, pressurized metered dose inhaler; SMI, Soft Mist™ Inhaler.
Figure 4 Algorithm for choosing inhaler device according to the patient’s inspiratory flow and ability to coordinate inhaler actuation and inspiration.

Using this algorithm, patients evaluated as having sufficient inspiratory flow with good coordination would be suited to a pMDI (with or without spacer), DPI, or SMI (ie, Respimat®, Boehringer Ingelheim); those with poor coordination may require a breath-actuated pMDI with spacer, DPI, or SMI.Citation12 For patients with insufficient inspiratory flow but adequate coordination (eg, patients with severe COPD or asthma and recurrent exacerbations), a pMDI (with or without spacer) or SMI would be suitable.Citation12 Options for patients with both insufficient inspiratory flow and poor inhaler coordination include a breath-actuated pMDI (with spacer), SMI, or nebulizer.Citation12 According to the algorithm, the attributes of the SMI make it an appropriate choice for all patients who are capable of conscious inhalation, irrespective of their hand–inhalation coordination or ability to generate sufficient inspiratory flow.

Components of patient preference and satisfaction with inhalers

As with all treatment decisions, it is important that the patient be involved in the choice of inhaler device. Patients are more likely to use a device effectively if they are comfortable with it and can use it even when they are incapable of achieving high inspiratory flow rates.Citation30

Many studies have investigated patients’ preferences for different inhaler types.Citation31,Citation35,Citation41,Citation47Citation50 While acknowledging that many preference studies are sponsored by the device or respiratory drug companies, such studies can provide valuable insights into the features that patients consider to be most important in a device. These include simplicity and convenience (eg, size, durability), and experience of use (eg, taste, side effects).Citation9,Citation35

Simplicity and convenience

Ease of use is an important factor in adherence with any device, but it is particularly important with drug delivery devices for maintenance treatment.Citation5 Use of electronics and other automations can reduce dependency on the patient for accurate technique, but it adds to the cost and complexity in terms of potential faults and possible cleaning issues.

In several surveys of device preference, ease of use has been ranked by patients as one of the most important features;Citation47,Citation48,Citation51,Citation52 however, perception of ease of use varies among patients. Patient perception of the level of convenience that is offered by the device might take into account its size, the instructions for use, its durability, the ease of cleaning the device, how comfortable it is to use (eg, for arthritic hands), and its portability.Citation48

Patients want procedures to be as simple as possible, and one study found that 18% of patients stopped inhaled therapy spontaneously due to perceived complexity.Citation53 Complexity and confusion between required techniques may ensue when mixed types of inhaler devices are prescribed for the delivery of different drug therapies.Citation34

Experience

Overall experience with an inhaler may be influenced by aspects unrelated to its physical form or functionality. Side effects from the drug, excipient, or inhaler use can affect the patient’s experience and willingness to continue using the device. Common issues with inhalers are the presence of an aftertaste, an effect on the throat (such as cold, dry, or sore), and cough.

Poor delivery and/or slow onset of action can reinforce a patient’s decision to voluntarily discontinue their regular medication. Indeed, lack of perceived benefit has been reported to account for 30% of patients with COPD intentionally discontinuing their therapy.Citation11

Apprehension regarding switching device

Patients may be apprehensive when switching to a new inhaler device because they may need to learn new skills and put these into practice with only limited training.Citation16

Experience with SMI versus other inhaler types

A number of studies comparing the patients’ experience of using SMI with other inhaler devices illustrate the influence of some of the factors already described in this section.

Hodder and PriceCitation35 have reviewed patient preference studies of Respimat®. The device was shown to be consistently well accepted and preferred by patients with COPD and asthma, with almost three-quarters of patients expressing a preference for Respimat® over a pMDI or Turbuhaler® DPI (AstraZeneca; ).Citation35 In another trial of device switching in patients with COPD, 21 of 29 patients (72%) considered Respimat® to be easier to use than HandiHaler®; no patient thought HandiHaler® was easier to use than Respimat®.Citation41

Figure 5 Proportions of patients indicating preference for Respimat® SMI versus alternative inhaler devices in three studies using the Patient Satisfaction and Preference Questionnaire.

Notes: Respimat® SMI versus (A) pMDI, (B) Turbuhaler®, (C) Diskus®. Republished with permission of Dove Medical Press, from Patient preferences for inhaler devices in chronic obstructive pulmonary disease: experience with Respimat Soft Mist inhaler, Hodder R, Price D, Int J Chron Obstruct Pulmon Dis, 4, copyright 2012;Citation35 permission conveyed through Copyright Clearance Center, Inc.
Abbreviations: pMDI, pressurized metered dose inhaler; SMI, Soft Mist™ Inhaler.
Figure 5 Proportions of patients indicating preference for Respimat® SMI versus alternative inhaler devices in three studies using the Patient Satisfaction and Preference Questionnaire.

Features relating to ease of handling (irrespective of patient age) are commonly reported as reasons for patients preferring Respimat® over other devices.Citation35 In the two aforementioned studies in which patients rated their satisfaction with Respimat® compared with a pMDI or Turbuhaler® DPI, Respimat® consistently scored significantly higher on ease of handling during use. Durability of the device and numerous aspects of device performance were also rated better with Respimat® than with pMDI or Turbuhaler®. Size was the only parameter on which Respimat® scored significantly worse than pMDI or Turbuhaler® in these studies; however, ease of carrying the device was not rated significantly worse, and there was no negative impact of size on ease of handling, which, as noted above, was rated higher for Respimat® in both studies.Citation48,Citation54

One survey of patients with COPD suggested that Respimat® had a significantly milder aftertaste than HandiHaler®, but there were no significant differences between the incidence of surveyed adverse events, including dry mouth and throat-related side effects.Citation55 In another survey, Respimat® was associated with increased incidence of cough within the first 4 weeks of switching from HandiHaler®; however, this was transient and most patients overcame having a cough as they got used to using Respimat®.Citation41

Satisfaction with performance of tiotropium Respimat®, including feeling of inhalation and reliable working of the inhaler, was shown in a patient preference study to be consistently better than that of a DPI (Turbuhaler®, AstraZeneca).Citation48

In a survey of patients with COPD that evaluated their handling experiences and preferences 8 weeks after switching from tiotropium HandiHaler® to Respimat®, 46% of patients stated that they preferred Respimat®.Citation55 In a follow-up study, 2–3 years later, the proportion of patients who expressed a preference for Respimat® had significantly increased to 80% (P<0.0001).Citation55 The different responses obtained during the first and second surveys may suggest that the change in inhaler device was stressful for the patients. This highlights the importance of involving patients in their treatment decisions to ensure that they are comfortable with, and understand the need for, any change in treatment.

Identifying the noncompliant patient

Improved compliance and adherence to therapy is a quest that is common to many chronic conditions. It is particularly important among patients with COPD in order to slow disease progression, maintain quality of life, and reduce mortality. Tools such as patient questionnaires and decision algorithms that can be easily adapted and implemented within daily practice may help physicians to select the devices most suited to their patients’ needs and abilities; they may also help to identify patients who have the potential for poor compliance or incorrect inhalation technique.

Involving the patient in their treatment decision-making process can change the physician–patient relationship from one of noncompliance to one of participative adherence to treatment.Citation47 But how can clinicians identify patients who are likely to be noncompliant with their inhaler therapy?

Identification of patients most likely to be noncompliant with therapy may enable more effective targeting of educational and behavioral resources, including continued assessment of inhaler technique, to foster improved compliance and maximize treatment efficacy. Sanduzzi et alCitation11 evaluated several methods that can assess whether a patient will be compliant with their prescribed inhaler; they proposed that simple, brief questionnaires based on the Morisky scaleCitation56 were most effective ().Citation11 These questionnaires address patients’ attitudes toward their medications and their health, the regularity of their medical check-ups, and their home life situation.Citation11 Similar preference questionnaires could be refined for ease of use in consultation rooms to gain a better understanding of individual patient preference and prescribing needs.

Table 3 Proposed psychosocioeconomic questions to ask patients with COPD to estimate compliance and to assess adherence phenotype and status

Conclusion

This review highlights the importance of understanding patient capabilities and preferences, and matching these to the most appropriate type of inhaler device; it also stresses the need to adopt ongoing training and monitoring of inhaler technique. With the large array of devices currently available to the prescribing physician, it is increasingly important to understand the factors that influence a patient’s preference and the likelihood of the inhaler being used correctly (eg, ease of use and convenience). Respimat® represents a novel class of inhaler (SMI) that overcomes some of the drawbacks associated with pMDIs and DPIs, such as nontargeted deposition of drug. It might be expected that SMIs in development will perform in a similar maner to Respimat® with regards to what benefits patients.

Patient satisfaction and preference studies have consistently shown Respimat® to be well accepted by patients, with higher levels of satisfaction and preference versus HandiHaler® and other device types. Whether the observed preference for Respimat® ultimately translates into improved adherence to therapy and improved outcomes remains to be evaluated in clinical studies.

Acknowledgments

Scientific writing and editorial support were provided by Godfrey Lisk, PhD, at PAREXEL, which were funded by Boehringer Ingelheim Pharma GmbH.

Disclosure

In the last 3 years, Pieter Nicolaas Richard Dekhuijzen and/or his department received research grants, unrestricted educational grants, and/or fees for lectures and advisory board meetings from Almirall, AstraZeneca, Boehringer-Ingelheim, Chiesi, GlaxoSmithKline, Mundipharma, Novartis, Takeda, and Teva.

In the last 3 years, Federico Lavorini received fees for lectures and advisory board meetings from AstraZeneca, Boehringer Ingelheim, Chiesi, Teva, and Cipla.

Omar S Usmani is supported by the National Institute for Health Research (NIHR) Respiratory Disease Biomedical Research Unit at the Royal Brompton and Harefield NHS Foundation Trust and Imperial College London, UK. He has also received grant funding to his institution and financial assistance to attend advisory boards and present at sym-posia from Aerocrine, Almirall, AstraZeneca, Boehringer Ingelheim, Chiesi, Cipla, Edmond Pharma, GlaxoSmithKline, Micro-Dose Therapeutx, Mundipharma, NAPP, Novartis, Pfizer, Philips-Respironics, Pieris-AG, Prosonix, Roche, Sandoz, Takeda, UCB, and Zentiva. The authors report no other conflicts of interest in this work.

References

  • LaubeBLThe expanding role of aerosols in systemic drug delivery, gene therapy and vaccination: an updateTransl Respir Med20142325505695
  • LavoriniFInhaled drug delivery in the hands of the patientJ Aerosol Med Pulm Drug Deliv201427641441825238005
  • Global Initiative for Chronic Obstructive Lung Disease (GOLD)Global Strategy for the Diagnosis, Management and Prevention of Chronic Obstructive Pulmonary Disease2015 Available from: http://goldcopd.org/global-strategy-diagnosis-management-prevention-copd-2016/Accessed 22 July 2016
  • Global Initiative for Asthma (GINA)Global Strategy for Asthma Management and Prevention Available from: http://ginasthma.org/2016-gina-report-global-strategy-for-asthma-management-and-prevention/Accessed July 22 2016
  • LavoriniFFontanaGAUsmaniOSNew inhaler devices – the good, the bad and the uglyRespiration201488131524902629
  • RamseySDSuboptimal medical therapy in COPD: exploring the causes and consequencesChest20001172 Suppl33S37S10673472
  • PriceDFletcherMvan der MolenTAsthma control and management in 8,000 European patients: the REcognise Asthma and LInk to Symptoms and Experience (REALISE) surveyNPJ Prim Care Respir Med2014241400924921985
  • LavoriniFMagnanADubusJCEffect of incorrect use of dry powder inhalers on management of patients with asthma and COPDRespir Med2008102459360418083019
  • PriceDBosnic-AnticevichSBriggsAInhaler competence in asthma: common errors, barriers to use and recommended solutionsRespir Med20131071374623098685
  • RauJLPractical problems with aerosol therapy in COPDRespir Care200651215817216441960
  • SanduzziABalboPCandoliPCOPD: adherence to therapyMultidiscip Respir Med2014916025485108
  • DekhuijzenPNVinckenWVirchowJCPrescription of inhalers in asthma and COPD: towards a rational, rapid and effective approachRespir Med2013107121817182124120398
  • PapiAHaughneyJVirchowJCRocheNPalkonenSPriceDInhaler devices for asthma: a call for action in a neglected fieldEur Respir J201137598298521532013
  • DekhuijzenPNBjermerLLavoriniFNinaneVMolimardMHaughneyJGuidance on handheld inhalers in asthma and COPD guidelinesRespir Med2014108569470024636812
  • CromptonGKBarnesPJBroedersMThe need to improve inhalation technique in Europe: a report from the Aerosol Drug Management Improvement TeamRespir Med200610091479149416495040
  • FinkJBRubinBKProblems with inhaler use: a call for improved clinician and patient educationRespir Care200550101360137416185371
  • Lee-WongMMayoPHResults of a programme to improve house staff use of metered dose inhalers and spacersPostgrad Med J20037993022122512743342
  • PressVGPincavageATPappalardoAAThe Chicago Breathe Project: a regional approach to improving education on asthma inhalers for resident physicians and minority patientsJ Natl Med Assoc2010102754855520690317
  • SelfTHArnoldLBCzosnowskiLMSwansonJMSwansonHInadequate skill of healthcare professionals in using asthma inhalation devicesJ Asthma200744859359817943567
  • DolovichMBAhrensRCHessDRDevice selection and outcomes of aerosol therapy: evidence-based guidelines: American College of Chest Physicians/American College of Asthma, Allergy, and ImmunologyChest2005127133537115654001
  • IbrahimMVermaRGarcia-ContrerasLInhalation drug delivery devices: technology updateMed Devices (Auckl)2015813113925709510
  • LavoriniFThe challenge of delivering therapeutic aerosols to asthma patientsISRN Allergy2013201310241823984095
  • LeachCLDavidsonPJBoudreauRJImproved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasoneEur Respir J1998126134613539877489
  • LabirisNRDolovichMBPulmonary drug delivery. Part II: the role of inhalant delivery devices and drug formulations in therapeutic effectiveness of aerosolized medicationsBr J Clin Pharmacol200356660061214616419
  • AcerbiDBrambillaGKottakisIAdvances in asthma and COPD management: delivering CFC-free inhaled therapy using Modulite technologyPulm Pharmacol Ther200720329030316890465
  • UsmaniOSBiddiscombeMFBarnesPJRegional lung deposition and bronchodilator response as a function of beta2-agonist particle sizeAm J Respir Crit Care Med2005172121497150416192448
  • UsmaniOSTreating the small airwaysRespiration201284644145323154684
  • AriAFinkJBGuidelines for aerosol devices in infants, children and adults: which to choose, why and how to achieve effective aerosol therapyExpert Rev Respir Med20115456157221859275
  • JuliusSMShermanJMHendelesLAccuracy of three electronic monitors for metered-dose inhalersChest2002121387187611888975
  • VinckenWDekhuijzenPRBarnesPThe ADMIT series – issues in inhalation therapy. 4) How to choose inhaler devices for the treatment of COPDPrim Care Respir J2010191102019890594
  • VoshaarTSpinolaMLinnanePComparing usability of NEXThaler® with other inhaled corticosteroid/long-acting beta2-agonist fixed combination dry powder inhalers in asthma patientsJ Aerosol Med Pulm Drug Deliv201427536337024299501
  • AndersonPUse of Respimat Soft Mist inhaler in COPD patientsInt J Chron Obstruct Pulmon Dis20061325125918046862
  • PitcairnGReaderSPaviaDNewmanSDeposition of corticosteroid aerosol in the human lung by Respimat Soft Mist inhaler compared to deposition by metered dose inhaler or by Turbuhaler dry powder inhalerJ Aerosol Med200518326427216181001
  • PriceDChrystynHKaplanAEffectiveness of same versus mixed asthma inhaler devices: a retrospective observational study in primary careAllergy Asthma Immunol Res20124418419122754711
  • HodderRPriceDPatient preferences for inhaler devices in chronic obstructive pulmonary disease: experience with Respimat Soft Mist inhalerInt J Chron Obstruct Pulmon Dis2009438139019888356
  • VirchowJCWhat plays a role in the choice of inhaler device for asthma therapy?Curr Med Res Opin200521Suppl 4S19S2516138941
  • MelaniASInhalatory therapy training: a priority challenge for the physicianActa Biomed200778323324518330086
  • DalbyRNEicherJZierenbergBDevelopment of Respimat® Soft Mist™ Inhaler and its clinical utility in respiratory disordersMed Devices (Auckl)2011414515522915941
  • ChodoshSFlandersJSKestenSSerbyCWHochrainerDWitekTJJrEffective delivery of particles with the HandiHaler dry powder inhalation system over a range of chronic obstructive pulmonary disease severityJ Aerosol Med200114330931511693842
  • ScichiloneNSpataforaMBattagliaSArrigoRBenfanteABelliaVLung penetration and patient adherence considerations in the management of asthma: role of extra-fine formulationsJ Asthma Allergy20136112123378776
  • AsakuraYNishimuraNMaezawaKTerajimaTKizuJChohnabayashiNEffect of switching tiotropium HandiHaler® to Respimat® Soft Mist™ Inhaler in patients with COPD: the difference of adverse events and usability between inhaler devicesJ Aerosol Med Pulm Drug Deliv2013261414522691112
  • NaveRMuellerHFrom inhaler to lung: clinical implications of the formulations of ciclesonide and other inhaled corticosteroidsInt J Gen Med201369910723516175
  • JacksonCLipworthBOptimizing inhaled drug delivery in patients with asthmaBr J Gen Pract1995454016836878745869
  • WeersJGBellJChanHKPulmonary formulations: what remains to be done?J Aerosol Med Pulm Drug Deliv201023Suppl 2S5S2321133800
  • BorovinaLRTremellenKEWalkerMPThe microbial contamination of pressurised metered-dose inhalers anonymously sourced from the South-East Queensland Australia community populationInt J Pharm Pract201220212913322416937
  • de VriesTWRottierBLVissermanHWilffertBWeelJThe influence of inhaled corticosteroids and spacer devices on the growth of respiratory pathogenic microorganismsAm J Infect Control200937323724018922602
  • LenneyJInnesJACromptonGKInappropriate inhaler use: assessment of use and patient preference of seven inhalation devices. EDICIRespir Med200094549650010868714
  • HodderRReesePRSlatonTAsthma patients prefer Respimat Soft Mist Inhaler to TurbuhalerInt J Chron Obstruct Pulmon Dis2009422523219554196
  • FreytagFRau-BergerHGlaabTWolfKRespimat® Soft Mist™ inhaler preferred to Diskus by patients with COPD and/or asthma [abstract]Am J Respir Crit Care Med2007175639
  • ChoraoPPereiraAMFonsecaJAInhaler devices in asthma and COPD – an assessment of inhaler technique and patient preferencesRespir Med2014108796897524873873
  • MolimardMColthorpePInhaler devices for chronic obstructive pulmonary disease: insights from patients and healthcare practitionersJ Aerosol Med Pulm Drug Deliv201528321922825265316
  • MooreACStoneSMeeting the needs of patients with COPD: patients’ preference for the Diskus inhaler compared with the HandihalerInt J Clin Pract200458544445015206499
  • SantusPPiccioloSProiettoADoctor-patient relationship: a resource to improve respiratory diseases managementEur J Intern Med201223544244622726373
  • SchurmannWSchmidtmannSMoroniPMasseyDQidanMRespimat Soft Mist inhaler versus hydrofluoroalkane metered dose inhaler: patient preference and satisfactionTreat Respir Med200541536115725050
  • HanadaSWadaSOhnoTSawaguchiHMurakiMTohdaYQuestionnaire on switching from the tiotropium HandiHaler to the Respimat inhaler in patients with chronic obstructive pulmonary disease: changes in handling and preferences immediately and several years after the switchInt J Chron Obstruct Pulmon Dis201510697725609941
  • MoriskyDEGreenLWLevineDMConcurrent and predictive validity of a self-reported measure of medication adherenceMed Care198624167743945130
  • MelaniASBonaviaMCilentiVInhaler mishandling remains common in real life and is associated with reduced disease controlRespir Med2011105693093821367593
  • Boehringer Ingelheim LtdSPIRIVA® HandiHaler® Summary of Product CharacteristicsBoehringer Ingelheim Ltd Available from: http://www.medicines.org.uk/emc/medicine/10039/SPC/Accessed 2012
  • Boehringer Ingelheim Pharma GmbH & Co. KGSummary of Product Characteristics – SPIRIVA® Respimat® 2.5 Microgram, Inhalation SolutionIngelheim, GermanyBoehringer Ingelheim Pharma GmbH & Co. KG2013 Available from: http://products.boehringer-ingelheim.com/products/prescription_medicines/respiratory/copd/spiolto/public/assets/spiriva_respimat_spc_published.pdfAccessed 2014
  • NewmanSImproving inhaler technique, adherence to therapy and the precision of dosing: major challenges for pulmonary drug deliveryExpert Opin Drug Deliv201411336537824386924
  • NewmanSPInhaler treatment options in COPDEur Respir Rev200514102108