Abstract
Auditory masking generated by two-tone complexes centered around 7 000 Hz was measured in 10 young adults with normal hearing sensitivity as a function of the frequency separation (δf) and SPL of the masker's components. Remote masking (1) was evident for test signals in the frequency region corresponding to the masker's δf; (2) increased with masker SPL, but at a rate less than that usually observed when lower frequency bands of noise are used as maskers, and (3) was relatively constant in magnitude for a given SPL as a function of the masker's δf. The masking produced in low-frequency regions by high-frequency two-tone complexes adds support to the hypothesis that remote masking is primarily a result of aural distortion.
Résumé
Nous avons mesuré sur 10 jeunes adultes à audition normale, l'effet de masque produit par un complexe de deux sons centrés aux environs de 7 000 Hz, en fonction de la valeur de la séparation fréquentielle (δf) et de l'intensité (SPL) des composants de ce complexe masqueur.
Le masking éloigné: 1) est évident pour les sons dont la fréquence correspond à δf; 2) s'accroiˇt avec l'intensité du masqueur, bien qu'avec un taux moindre que celui observé lorsqu'on utilise comme masqueur des bandes de bruit de basse fréquence; 3) est relativement constant en importance pour une intensité donnée et en fonction δf du masqueur.
Le masking, ainsi produit dans des régions fréquentielles basses par des complexes de deux sons de haute fréquence, donne un argument supplémentaire à l'hypothèse d'après laquelle le masking éloigné serait avant tout le résultat d'une distorsion de l'audition.