174
Views
5
CrossRef citations to date
0
Altmetric
Research Article

Reduction of fractional exhaled nitric oxide (FENO) and its variation by mouth wash

, , &
Pages 253-257 | Received 08 Nov 2011, Accepted 10 Jan 2012, Published online: 10 Feb 2012
 

Abstract

Introduction. Although fractional exhaled nitric oxide (FENO) measurement is a widely used method to assess eosinophilic bronchial inflammation, knowledge on extrabronchial factors affecting measurement results is still limited. Our aim was to study the eventual modifying effect of mouth wash on FENO values and their variability. Materials and Methods. A total of 16 healthy Caucasian women performed FENO measurements with a chemiluminescence analyzer according to ATS guidelines (2005), with an exhalation flow rate of 50 ml/s against a flow resistor. On the first day three successive FENO measurements were performed: first after mouth wash with water containing sodium and potassium bicarbonates, and thereafter twice without mouth wash. On the second day, the FENO measurement was first performed without mouth wash, then with preceding mouth wash twice, and finally without preceding mouth wash. Each FENO measurement consisted of three measurements with the average reported and the time interval between the FENO measurements was 10 minutes on both days. Results. The FENO level increased significantly in the subsequent measurements performed without mouth wash (p < 0.01), when the baseline measurement was performed with mouth wash. On the second day, the FENO level decreased significantly in measurements performed with preceding mouth wash, compared with the first measurement without preceding mouth wash (p < 0.01). Conclusion. The results indicate a slight but statistically significant decreasing effect of mouth wash on the FENO. The findings suggest that mouth wash prior to FENO measurement could standardize the measurement procedure, by decreasing the effect of NO produced in the mouth on the measurement result.

Acknowledgements

Mrs Tarja Jaakola is acknowledged for carrying out skillful FENO measurements.

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.