Abstract
Gamma-camera imaging of the abdomen after injection of autologous 111 In-labelled platelets was applied for localization of gastrointestinal bleeding in a study of 22 patients. In 15 studies showing scintigraphic signs of bleeding, the clinical presentation included occult bleeding in 6, melaena in 4, and bloody stools in 5. Scintigraphy could be done repeatedly for up to 1 week after a single tracer injection. The time interval between the injection and scintigraphic visualization of bleeding ranged from 10 min to 68 h, being longest in cases of occult bleeding. In most cases the scintigraphic findings were supported by other diagnostic modalities, including surgical removal of presumed sources of bleeding. In seven studies without scintigraphic signs of bleeding a probable source of bleeding was identified by other means in one patient. The 111 In-platelet method seems to be a promising method for localization of gastrointestinal bleeding which may prove particularly useful in cases of occult or recurrent bleeding.