Purpose: The dialysability of ioversol was investigated in 12 patients with chronic renal failure, on 4-h hemodialysis.

Material and Methods: One hundred ml of ioversol (320 mg I/ml) was injected in less than 10 min during CT. Hemodialysis was commenced within 30 min of starting the contrast medium injection and was continued for 4 h. Blood was sampled before and at 15 min, 30 min, 1 h, 2 h, and 4 h after the start of hemodialysis. Mean dialysance of ioversol was 114 to 129 ml/min and the elimination rate was 82.5±5.1% 4 h after starting hemodialysis. The half-life of ioversol during hemodialysis was 1.80±0.38 h. The only side effects of the ioversol injection were heat sensations, which were experienced by 3 patients.

Results: As ioversol was effectively removed from the body during the 4 h of hemodialysis and no severe adverse reactions were observed, we conclude that ioversol is suitable for use in hemodialyzed patients.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.