Evaluation of methods for selecting the midventilation bin in 4DCT scans of lung cancer patients

, , , &
Pages 1715-1722 | Received 31 May 2012, Accepted 22 Dec 2012, Published online: 22 Jan 2013
 

Abstract

Background. In lung cancer radiotherapy, planning on the midventilation (MidV) bin of a four-dimensional (4D) CT scan can reduce the systematic errors introduced by respiratory tumour motion compared to conventional CT. In this study four different methods for MidV bin selection are evaluated. Material and methods. The study is based on 4DCT scans of 19 patients with a total of 23 peripheral lung tumours having peak-to-peak displacement ≥ 5 mm in at least one of the left-right (LR), anterior-posterior (AP) or cranio-caudal (CC) directions. For each tumour, the MidV bin was selected based on: 1) visual evaluation of tumour displacement; 2) rigid registration of tumour position; 3) diaphragm displacement in the CC direction; and 4) carina displacement in the CC direction. Determination of the MidV bin based on the displacement of the manually delineated gross tumour volume (GTV) was used as a reference method. The accuracy of each method was evaluated by the distance between GTV position in the selected MidV bin and the time-weighted mean position of GTV throughout the bins (i.e. the geometric MidV error). Results. Median (range) geometric MidV error was 1.4 (0.4–5.4) mm, 1.4 (0.4–5.4) mm, 1.9 (0.5–6.9) mm, 2.0 (0.5–12.3) mm and 1.1 (0.4–5.4) mm for the visual, rigid registration, diaphragm, carina, and reference method. Median (range) absolute difference between geometric MidV error for the evaluated methods and the reference method was 0.0 (0.0–1.2) mm, 0.0 (0.0–1.7) mm, 0.7 (0.0–3.9) mm and 1.0 (0.0–6.9) mm for the visual, rigid registration, diaphragm and carina method. Conclusion. The visual and semi-automatic rigid registration methods were equivalent in accuracy for selecting the MidV bin of a 4DCT scan. The methods based on diaphragm and carina displacement cannot be recommended without modifications.

Acknowledgements

The results of the present study were presented in part in a poster at the ICCR meeting 2010 in Amsterdam.

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

This work has been supported by a research grant from the Danish Center for Interventional Research in Radiation Oncology (CIRRO). Stine Korreman was supported by a research grant from Varian Medical Systems, Inc, up to 2010, and Carsten Brink was supported by a research grant from Electa AB.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.