Infrared cameras are potential traceable “fixed points” for future thermometry studies

, , , &
Pages 485-489 | Received 05 Feb 2015, Accepted 20 Jun 2015, Published online: 15 Oct 2015
 

Abstract

The National physical laboratory (NPL) requires “fixed points” whose temperatures have been established by the International Temperature Scale of 1990 (ITS 90) be used for device calibration. In practice, “near” blackbody radiators together with the standard platinum resistance thermometer is accepted as a standard. The aim of this study was to report the correlation and limits of agreement (LOA) of the thermal infrared camera and non-contact infrared temporal thermometer against each other and the “near” blackbody radiator. Temperature readings from an infrared thermography camera (FLIR T650sc) and a non-contact infrared temporal thermometer (Hubdic FS-700) were compared to a near blackbody (Hyperion R blackbody model 982) at 0.5 °C increments between 20–40 °C. At each increment, blackbody cavity temperature was confirmed with the platinum resistance thermometer. Measurements were taken initially with the thermal infrared camera followed by the infrared thermometer, with each device mounted in turn on a stand at a fixed distance of 20 cm and 5 cm from the blackbody aperture, respectively. The platinum thermometer under-estimated the blackbody temperature by 0.015 °C (95% LOA: −0.08 °C to 0.05 °C), in contrast to the thermal infrared camera and infrared thermometer which over-estimated the blackbody temperature by 0.16 °C (95% LOA: 0.03 °C to 0.28 °C) and 0.75 °C (95% LOA: −0.30 °C to 1.79 °C), respectively. Infrared thermometer over-estimates thermal infrared camera measurements by 0.6 °C (95% LOA: −0.46 °C to 1.65 °C). In conclusion, the thermal infrared camera is a potential temperature reference “fixed point” that could substitute mercury thermometers. However, further repeatability and reproducibility studies will be required with different models of thermal infrared cameras.

Declaration of interest

The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.