Abstract
In this study we assessed the clinical utility of measuring all major rheumatoid factor (RF) isotypes (IgG, IgA, and IgM) in the diagnostic immunology laboratory using an enzyme-linked immunoassay (ELISA). An improved method for IgG-RF was tested which employed a commercially available monoclonal anti-human IgG Fd antibody and did not require pepsin digestion of samples. We detected elevated levels of all three RF isotypes in a population of hospitalized rheumatoid arthritis patients (n=109). We demonstrated a significant association between IgM and IgA RF which occurred in 36% of our subjects, while less than 6% had IgM + IgG RF or IgG + IgA RF. A comparison of the IgM ELISA with the Rheuruaton revealed a statistically significant correlation (r=0.65, p=0.0001). In addition, the two methodologies were equivalent in sensitivity (ELISA: 76%, Rheumaton: 78%). However, the ELISA procedure was more time consuming, costly, and required greater technical expertise. The following clinical and laboratory findings were significantly associated with RF isotypes: IgG RF and the presence of rheumatoid nodules (p=0.03), elevated erythrocyte sedimentation rate (ESR) and IgG RF (p=0.007), and elevated ESR and IgM RF (p=0.0009). Our ELISA methodology did not provide significant advantages over existing techniques to justify its use as part of the routine laboratory assessment of rheumatoid factor.