The Role of Electrolyte in Lesion Size Using an Irrigated Radiofrequency Electrode

, , , &
Pages 339-348 | Received 28 Jan 1997, Accepted 15 Jul 1997, Published online: 09 Jul 2009
 

Abstract

Multiple attempts have been made to eliminate atrial fibrillation by performing the surgical maze procedure with radiofrequency energy. Currently, this is limited because of the risk of atrial perforation and the lack of transmural penetration. Saline irrigation has been investigated as a method of radiofrequency cautery tip cooling to prevent rapid temperature and impedance rises, which have been shown to lead to perforation or decreased radiofrequency penetration after eschar formation. There are few data on the influence that different types of electrolyte irrigation solutions have on lesion depth. Using a novel hollow cautery pen, we infixed either an electrolyte solution (0.9%, 3%, 14.6%, or 23.4% sodium chloride), a nonelectrolyte solution (1.5% glycine), or no irrigation to produce 819 lesions on 14 left ventricles in swine using radiofrequency energy (450±10 kHz) applied at two output settings (20 and 75 watts). The nonelectrolyte solution increased lesion depth compared with no infusion at 20 watts but produced shallower lesion depths compared with electrolyte solutions at 75 watts. Compared with the other electrolyte solutions, the 0.9% sodium chloride solution produced the deepest lesions (3.34 ± 0.06 mm) at 75 watts (p < 0.001). As the concentration of electrolyte increased, lesion depth decreased unless generator output increased. Formation of eschar and tissue destruction was seen in the noninfusion and nonelectrolyte groups but not in the electrolyte group. A conductive media coupled with radiofrequency energy allowed for greater lesion depth than irrigated cooling with a nonelectrolyte solution or no irrigation. There was an inverse relationship between electrolyte concentration and lesion depth. We conclude that the concentration of electrolyte irrigant is an important consideration when choosing a solution to improve transmural penetration and decrease the risk of tissue destruction from radiofrequency energy.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.