Reliability of the chin tuck neck flexion test for assessing endurance of short neck flexors in healthy individuals

, MSc, PhD, , MSc, PhD, , MSc, PhD & , PhD
Pages 299-302 | Received 09 Jul 2014, Accepted 26 Oct 2014, Published online: 14 Jan 2015
 

Abstract

Objectives: The aim of the study was to examine of the intra-rater reliability of the chin tuck neck flexion (CTNF) test for assessing the endurance of neck flexors. Materials and methods: The study was performed at the Cardiorespiratory laboratory of the Physiotherapy Department, School of Health and Caring Professions, TEI Lamia, Greece. Twenty healthy volunteers (males/females: 9/11, age: 22.2 ± 1.7 y ears) with no known musculoskeletal, cardiovascular, pulmonary, neurological, or psychiatric disorder were recruited. The participants were positioned in a supine position and were asked to raise their head 2.5 cm above the plinth and to maintain this position for as long as possible without losing craniocervical or cervical flexion. This test was repeated three times with 5-min intervals between the trials. Results: The results showed that this test could discriminate between neck flexor endurance in men and women. However, although the test seems to be highly reliable (ICC: 0.81–0.88), it presents unsatisfactory standard error of measurement (SEM: 10.7–14.7 s) and smallest detectable differences (SDD: 80.5–110.9%). Furthermore, subgroup analysis showed the test seems to be more reliable for women (ICC: 0.93–0.94) than for men (ICC: 0.68–0.8), but the SEM and SDD values for them remain unsatisfactory (SEM: 4.4–5.3 s, SDD: 57.5–63.99%). Conclusions: Due to high reproducibility and discriminant validity, clinicians and researchers might want to consider using the CTNF test for the assessment of neck flexor endurance. However, they should seek alternative measurement tools when they want to avoid a large measurement error.

Declaration of interest

The authors report no conflicts of interest.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.