The characteristics of Audioscan and DPOAE measures in tinnitus patients with normal hearing thresholds

, , &
Pages 309-317 | Received 29 Jan 2013, Accepted 18 Nov 2013, Published online: 05 Feb 2014
 

Abstract

Objectives: To investigate auditory dysfunction in patients with tinnitus and normal hearing thresholds using two sensitive audiological measures. Design: The study was designed to investigate the characteristics of Audioscan and DPOAE tests in tinnitus patients with normal hearing thresholds. Audioscan and DPOAE notches were analysed and compared. All tests were performed in a sound-treated chamber or in a sound-treated room. Study sample: Forty-five tinnitus patients with normal hearing thresholds were examined following a written clinical protocol. Results: The averaged hearing levels obtained from tinnitus participants were significantly worse at high frequencies than those derived from the normative data. There was a significantly higher prevalence of Audioscan and DPOAE notches, whose central frequencies matched tinnitus frequencies in the mid-frequency regions, but not in the low- and high-frequency regions. A significant correlation was found between the centre frequencies of the Audioscan notches and the DPOAE notches from 500 to 4000 Hz. Conclusion: Tinnitus in different frequency regions may be associated with different underlying mechanisms of tinnitus generation. Some negative results on the Audioscan and DPOAE notches matching tinnitus pitches may be due to a limited set of discrete frequencies used for the tinnitus pitch matching test.

Acknowledgements

We would like to thank the anonymous reviewers and Dr. Grant Searchfield for their helpful suggestions. We would also like to acknowledge Mrs Norma Meechem and Dr. Christopher Wigham for their proof reading. W.S. Ishak was supported by Ministry of Higher Education (MOHE) Malaysia and Universiti Kebangsaan Malaysia (UKM) as part of her PhD research at the University of Bristol, UK.

Declaration of interest: No conflicts of interest.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.