786
Views
19
CrossRef citations to date
0
Altmetric
ORIGINAL RESEARCH

Kurtosis and Skewness of Density Histograms on Inspiratory and Expiratory CT Scans in Smokers

, , , , , , , , & show all
Pages 13-20 | Published online: 08 Feb 2011
 

Abstract

The aim of this study is to evaluate the relationship between lung function and kurtosis or skewness of lung density histograms on computed tomography (CT) in smokers. Forty-six smokers (age range 46−81 years), enrolled in the Lung Tissue Research Consortium, underwent pulmonary function tests (PFT) and chest CT at full inspiration and full expiration. On both inspiratory and expiratory scans, kurtosis and skewness of the density histograms were automatically measured by open-source software. Correlations between CT measurements and lung function were evaluated by the linear regression analysis. Although no significant correlations were found between inspiratory kurtosis or skewness and PFT results, expiratory kurtosis significantly correlated with the following: the percentage of predicted value of forced expiratory volume in the first second (FEV1), the ratio of FEV1 to forced vital capacity (FVC), and the ratio of residual volume (RV) to total lung capacity (TLC) (FEV1%predicted, R = −0.581, p < 0.001; FEV1/FVC, R = −0.612, p < 0.001; RV/TLC, R = 0.613, p < 0.001, respectively). Similarly, expiratory skewness showed significant correlations with PFT results (FEV1%predicted, R = −0.584, p < 0.001; FEV1/FVC, R = −0.619, p < 0.001; RV/TLC, R = 0.585, p < 0.001, respectively). Also, the expiratory/inspiratory (E/I) ratios of kurtosis and skewness significantly correlated with FEV1%predicted (p < 0.001), FEV1/FVC (p < 0.001), RV/TLC (p < 0.001), and the percentage of predicted value of diffusing capacity for carbon monoxide (kurtosis E/I ratio, p = 0.001; skewness E/I ratio, p = 0.03, respectively). We conclude therefore that expiratory values and the E/I ratios of kurtosis and skewness of CT densitometry reflect airflow limitation and air-trapping. Higher kurtosis or skewness on expiratory CT scan indicates more severe conditions in smokers.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.