MRI evaluation of the inferior glenohumeral ligament: Comparison with arthroscopic findings in 81 shoulders

, , &
Pages 163-166 | Received 04 May 1997, Accepted 26 Dec 1997, Published online: 08 Jul 2009
 

Abstract

Arthroscopic Bankart repair, using staples, requires a thick and wide anterior band of the inferior glenohumeral ligament. We compared MRI and arthroscopic findings of the ligament in 81 shoulders with traumatic anterior glenohumeral instability. When fluid was present in the shoulder, sensitivity and specificity of the MRI evaluation for the presence of a thick and wide ligament were 82% and 100%, respectively. In shoulders without joint fluid, the condition of the ligament was evaluated according to the presence of a low- or moderate-signal triangle structure on the anterior margin of the glenoid cavity in the 3 MR images obtained from the inferior 2 cm of the glenoid. Sensitivity and specificity of the MRI evaluation in cases without fluid were 84% and 93%, respectively. The MR technique needs to be further improved to achieve better sensitivity for preoperative selection of shoulders suitable for Bankart repair with staples.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.