Reliability of plastic cups to measure breast volume

, &
Pages 254-258 | Accepted 27 Nov 2013, Published online: 16 Dec 2013
 

Abstract

Breast volume measurement is valuable in clinical practice, and various methods have been used. Nonetheless, no commonly accepted standard technique exists for clinical everyday use and there is no optimal method that is quick, cheap, minimally invasive, and acceptable for the patient and for the surgeon. Previously, a study has shown that the volume measured with plastic cups differed little from that measured from mastectomy specimens. The aim of the present study was to test the reliability of breast volume measurements with plastic cups as a tool to measure breast volume in everyday clinical practice. The plastic cups were designed by the senior author (AR) and comprise 14 cups from 125 millilitres (ml) to 2000 ml. Six raters measured 12 breasts on the same day. The results show that there is a certain variation between different raters, and that a certain rater seems to consistently measure slightly lower or higher volumes than the other raters. The Intra Class Correlation (ICC) coefficient of average measures between raters is 0.89, that is, the agreement between different raters is high. According to the Bland-Altman plot, the overall assessment of the comparisons of measurements between the different raters shows that the direction of the mean differences is close to zero. The limits of agreements of the differences were within ±56 ml. The coefficient of variation (CV) between different raters was 14%. Breast volume measurement with plastic cups is an easily usable quick and cheap way to measure breast volume in everyday clinical practice. The measurements have an acceptable reliability.

Acknowledgements

We are indebted to the staff of the Department of Plastic and Reconstructive Surgery, who generously let us perform measurements on their breasts, as well as to the surgeons and nurses who performed the measurements. We thank associate professor Håkan Brorson for fruitful discussions on the coefficient of variation.

Declaration of interest

The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.