Ke-Wei Xu, Qi Gao, Min Wan & Ke Zhang. (2023) Mock circulatory loop applications for testing cardiovascular assist devices and in vitro studies. Frontiers in Physiology 14.
Crossref
Sumanta Laha, Indranil Ghosh & Prasanta Kumar Das. 2023. Fluid Mechanics and Fluid Power (Vol. 3). Fluid Mechanics and Fluid Power (Vol. 3)
297
302
.
S G Rahul, R Chitra, Seeram Sai Sudheer, Palevla Venkata Naga Ravi Teja, Amruthavalli Archakam & Jaswanth Reddy Modium. (2021) Model Based Cardiac Control System For The Left Heart Using LabView. Model Based Cardiac Control System For The Left Heart Using LabView.
David J. Horvath, Kiyotaka Fukamachi & Jamshid H. Karimov. 2020. Mechanical Support for Heart Failure. Mechanical Support for Heart Failure
449
465
.
Takuma Miyamoto, David J. Horvath, Dennis W. Horvath, Jamshid H. Karimov, Nicole Byram, Barry D. KubanKiyotaka Fukamachi. (2019) Simulated Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart Using the Virtual Mock Loop. ASAIO Journal 65:6, pages 565-572.
Crossref
Jacob M. King, Clint A. Bergeron & Charles E. Taylor. (2018) Development of an adaptive pulmonary simulator for in vitro analysis of patient populations and patient-specific data. Computer Methods and Programs in Biomedicine 161, pages 93-102.
Crossref
Scott C. McKenzie, Kimble Dunster, Wandy Chan, Martin R. Brown, David G. Platts, George Javorsky, Chris Anstey & Shaun D. Gregory. (2017) Reliability of thermodilution derived cardiac output with different operator characteristics. Journal of Clinical Monitoring and Computing 32:2, pages 227-234.
Crossref
Jo P. Pauls, Nicole Bartnikowski, So-Hyun Jansen, Einly Lim & Kurt Dasse. 2018. Mechanical Circulatory and Respiratory Support. Mechanical Circulatory and Respiratory Support
407
438
.
Yaxin Wang, P. Alex Smith, Paul De-Sciscio, Luiz C. Sampaio, William E. Cohn, Liping Xu & Richard A. McMahon. (2017) Replication of pressure-volume loop with controllable ESPVR and EDPVR curves on a personalized mock circulatory loop based on elastance function. Replication of pressure-volume loop with controllable ESPVR and EDPVR curves on a personalized mock circulatory loop based on elastance function.
Shaun D. Gregory, Michael C. Stevens, Eric L. Wu, Jo P. Pauls, Matthias Kleinheyer & John F. Fraser. (2016) Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation. Annals of Biomedical Engineering 44:9, pages 2674-2682.
Crossref
Shaun D. Gregory, Helena Cooney, Sara Diab, Chris Anstey, Ogilvie Thom & John F. Fraser. (2015) In vitro evaluation of an ultrasonic cardiac output monitoring (USCOM) device. Journal of Clinical Monitoring and Computing 30:1, pages 69-75.
Crossref
Casey Lo, Shaun Gregory, Michael Stevens, Deirdre Murphy & Silvana Marasco. (2015) Banding the Right Ventricular Assist Device Outflow Conduit: Is It Really Necessary With Current Devices?. Artificial Organs 39:12, pages 1055-1061.
Crossref
Shaun D. Gregory, Emma Schummy, Mark Pearcy, Jo P. Pauls, Geoff Tansley, John F. Fraser & Daniel Timms. (2014) A Compliant, Banded Outflow Cannula for Decreased Afterload Sensitivity of Rotary Right Ventricular Assist Devices. Artificial Organs 39:2, pages 102-109.
Crossref
Michael C. Stevens, Shaun D. Gregory, Frank Nestler, Bruce Thomson, Jivesh Choudhary, Bruce Garlick, Jo P. Pauls, John F. Fraser & Daniel Timms. (2014) In Vitro and In Vivo Characterization of Three Different Modes of Pump Operation When Using a Left Ventricular Assist Device as a Right Ventricular Assist Device. Artificial Organs 38:11, pages 931-939.
Crossref
Jo P. Pauls, Shaun D. Gregory, Michael Stevens & Geoff Tansley. (2014) In-vitro evaluation of physiological controller response of rotary blood pumps to changes in patient state. In-vitro evaluation of physiological controller response of rotary blood pumps to changes in patient state.
Po-Lin Hsu, Nima Hatam, Jan Unterkofler, Andreas Goetzenich, Madeleine McIntyre, Kai Chun Wong, Christina Egger, Thomas Schmitz-Rode, Rüdiger Autschbach & Ulrich Steinseifer. (2014) Selective reduction of afterload in right heart assist therapy: a mock loop study. Interactive CardioVascular and Thoracic Surgery 19:1, pages 76-81.
Crossref
Shaun D. Gregory, Michael C. Stevens, Eric Wu, John F. Fraser & Daniel Timms. (2013) In Vitro Evaluation of Aortic Insufficiency With a Rotary Left Ventricular Assist Device. Artificial Organs 37:9, pages 802-809.
Crossref
Shaun D. Gregory, Mark J. Pearcy, John Fraser & Daniel Timms. (2013) Evaluation of Inflow Cannulation Site for Implantation of Right‐Sided Rotary Ventricular Assist Device. Artificial Organs 37:8, pages 704-711.
Crossref
Adathala Rajeev, Natarajan Sivakumaran, Sreedharan Sujesh & Chirathodi Vayalappil Muraleedharan. (2012) A linear after-load model for a cardio-vascular pulse duplicator. A linear after-load model for a cardio-vascular pulse duplicator.
Shaun David Gregory, Mark John Pearcy & Daniel Timms. (2012) Passive Control of a Biventricular Assist Device With Compliant Inflow Cannulae. Artificial Organs 36:8, pages 683-690.
Crossref
Shaun David Gregory, Daniel Timms, Nicholas Richard Gaddum, Charles McDonald, Mark John Pearcy & John F. Fraser. (2011) In Vitro Evaluation of a Compliant Inflow Cannula Reservoir to Reduce Suction Events With Extracorporeal Rotary Ventricular Assist Device Support. Artificial Organs 35:8, pages 765-772.
Crossref
D. L. Timms, S. D. Gregory, M. C. Stevens & J. F. Fraser. (2011) Haemodynamic modeling of the cardiovascular system using mock circulation loops to test cardiovascular devices. Haemodynamic modeling of the cardiovascular system using mock circulation loops to test cardiovascular devices.
Daniel L. Timms, Shaun D. Gregory, Nicholas A. Greatrex, Mark J. Pearcy, John F. Fraser & Ulrich Steinseifer. (2010) A Compact Mock Circulation Loop for the In Vitro Testing of Cardiovascular Devices. Artificial Organs 35:4, pages 384-391.
Crossref
Daniel Timms, Shaun Gregory, Po‐Lin Hsu, Bruce Thomson, Mark Pearcy, Keith McNeil, John Fraser & Ulrich Steinseifer. (2010) Atrial Versus Ventricular Cannulation for a Rotary Ventricular Assist Device. Artificial Organs 34:9, pages 714-720.
Crossref