21
Views
22
CrossRef citations to date
0
Altmetric
ANALYTICAL BIOCHEMISTRY AND CLINICAL ANALYSIS

Amperometric Sensor and Immobilized Enzyme Electrode for the Determination of Enzymatic Activities

, &
Pages 525-540 | Received 24 Mar 1983, Accepted 28 Mar 1983, Published online: 06 Dec 2006

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (3)

Serge Cosnier & Christophe Innocent. (1994) Detection of Galactose and Lactose by a Poly(Amphiphilic Pyrrole)-Galactose Oxidase Electrode. Analytical Letters 27:8, pages 1429-1442.
Read now
C.H. Assolant-vinet & P.R. Coulet. (1986) New Immobilized Enzyme Membranes for Tailor-Made Biosensors. Analytical Letters 19:7-8, pages 875-885.
Read now

Articles from other publishers (19)

Audrey Sassolas, Loïc J. Blum & Béatrice D. Leca-Bouvier. (2009) New electrochemiluminescent biosensors combining polyluminol and an enzymatic matrix. Analytical and Bioanalytical Chemistry 394:4, pages 971-980.
Crossref
Audrey Sassolas, Loïc J. Blum & Béatrice D. Leca-Bouvier. (2009) Polymeric luminol on pre-treated screen-printed electrodes for the design of performant reagentless (bio)sensors. Sensors and Actuators B: Chemical 139:1, pages 214-221.
Crossref
Pierre Gros & Maurice Comtat. (2004) A bioelectrochemical polypyrrole-containing Fe(CN)63− interface for the design of a NAD-dependent reagentless biosensor. Biosensors and Bioelectronics 20:2, pages 204-210.
Crossref
A. P. Girard-Egrot, R. M. Morélis & P. R. Coulet. (1998) Influence of Lipidic Matrix and Structural Lipidic Reorganization on Choline Oxidase Activity Retained in LB Films. Langmuir 14:2, pages 476-482.
Crossref
Fumio Mizutani & Soichi Yabuki. (1997) Rapid determination of glucose and sucrose by an amperometric glucose-sensing electrode combined with an invertase/mutarotase-attached measuring cell. Biosensors and Bioelectronics 12:9-10, pages 1013-1020.
Crossref
Loïc J. Blum, Sabine M. Gautier, Agnès Berger, Philippe E. Michel & Pierre R. Coulet. (1995) Multicomponent organized bioactive layers for fiber-optic luminescent sensors. Sensors and Actuators B: Chemical 29:1-3, pages 1-9.
Crossref
M.A.Saka Amini & J.J. Vallon. (1994) Comparison of performances and analytical applications of two immobilized oxalate oxidase sensors. Analytica Chimica Acta 299:1, pages 75-79.
Crossref
Agnès Berger & Loïc J. Blum. (1994) Enhancement of the response of a lactate oxidase/peroxidase-based fiberoptic sensor by compartmentalization of the enzyme layer. Enzyme and Microbial Technology 16:11, pages 979-984.
Crossref
Bernard R. Pieters & Gilbert Bardeletti. (1992) Enzyme immobilization on a low-cost magnetic support: Kinetic studies on immobilized and coimmobilized glucose oxidase and glucoamylase. Enzyme and Microbial Technology 14:5, pages 361-370.
Crossref
R.M. Morelis, P.R. Coulet, A. Simplot, C. Boisson & G. Guibaud. (1991) Rapid and sensitive discriminating determination of acetylcholinesterase activity in amniotic fluid with a choline sensor. Clinica Chimica Acta 203:2-3, pages 295-303.
Crossref
Fumio Mizutani & Michihiko Asai. (1990) Simultaneous determination of glucose and sucrose by a glucose-sensing enzyme electrode combined with an invertase-attached cell. Analytica Chimica Acta 236, pages 245-250.
Crossref
Franck Cheillan, Huguette Lafont, Elise Termine, Florence Fernandez, Paul Sauve & Guy Lesgards. (1989) Molecular characteristics of the cholesterol oxidase and factors influencing its activity. Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology 999:3, pages 233-238.
Crossref
Sophie Peguin, Pierre R. Coulet & Gilbert Bardeletti. (1989) Pyruvate oxidase and oxaloacetate decarboxylase enzyme electrodes. Analytica Chimica Acta 222:1, pages 83-93.
Crossref
Michael P. Coughlan, Marek P.J. Kierstan, Peter M. Border & Anthony P.F. Turner. (1988) Analytical applications of immobilised proteins and cells. Journal of Microbiological Methods 8:1-2, pages 1-50.
Crossref
P. R. Coulet. 1988. Analytical Uses of Immobilized Biological Compounds for Detection, Medical and Industrial Uses. Analytical Uses of Immobilized Biological Compounds for Detection, Medical and Industrial Uses 319 327 .
Loïc J. Blum, Pierre R. Coulet & Daniéle C. Gautheron. (2004) Collagen strip with immobilized luciferase for ATP bioluminescent determination. Biotechnology and Bioengineering 27:3, pages 232-237.
Crossref
B. Maïsterrena, G. Bardeletti & P.R. Coulet. (1985) Product distribution in diffusion-cell compartments separated by an immobilized enzyme membrane. Journal of Membrane Science 22:2-3, pages 175-186.
Crossref
Fumio Mizutani, Tadae Yamanaka, Yoshikazu Tanabe & Keishiro Tsuda. (1985) An enzyme electrode forl-lactate with a chemically-amplified response. Analytica Chimica Acta 177, pages 153-166.
Crossref
G.J. Moody & J.D.R. Thomas. 1984. 209 263 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.