6
Views
27
CrossRef citations to date
0
Altmetric
Original Articles

Investigation of Instrument Parameters for the Application of Peroxyoxalate Cheminescence Detection to Microbore Chromatography

&
Pages 1539-1552 | Received 24 Apr 1984, Accepted 06 Jun 1984, Published online: 06 Dec 2006

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

György Orosz, RichardS. Givens & RichardL. Schowen. (1996) A Model for Mechanism of Peroxyoxalate Chemiluminescence as Applied to Detection in Liquid Chromatography. Critical Reviews in Analytical Chemistry 26:1, pages 1-27.
Read now

Articles from other publishers (26)

Zian Lin & Zenghong Xie. (2008) Direct determination of amino acids by pressurized capillary electrochromatography with chemiluminescence detection. Journal of Separation Science 31:15, pages 2852-2859.
Crossref
Zian Lin, Jian Lin, Xiaoping Wu, Xucong Lin & Zenghong Xie. (2008) Evaluation of band broadening in chemiluminescence detection coupled to pressurized capillary electrochromatography with an off‐column coaxial flow interface. ELECTROPHORESIS 29:2, pages 401-409.
Crossref
Ling Zhong & J. T. Maloy. (1998) HPLC Band Shape Analysis for Postcolumn Chemiluminescence Detection Obtained by Finite-Difference Simulation:  The Chemical Band Narrowing Effect. Analytical Chemistry 70:6, pages 1100-1107.
Crossref
Bo Huang, Jian-jun Li, Le Zhang & Jie-ke Cheng. (1996) On-Line Chemiluminescence Detection for Capillary Ion Analysis. Analytical Chemistry 68:14, pages 2366-2369.
Crossref
Hang Li & Roger Westerholm. (1994) Determination of mono- and di-nitro polycyclic aromatic hydrocarbons by on-line reduction and high-performance liquid chromatography with chemiluminescence detection. Journal of Chromatography A 664:2, pages 177-182.
Crossref
Toshimasa Toyo'oka, Hitesh P. Chokshi, Richard S. Givens, Robert G. Carlson, Susan M. Lunte & Theodore Kuwana. (2005) Fluorescence and chemiluminescence detection of oxazole‐labelled amines and thiols. Biomedical Chromatography 7:4, pages 208-216.
Crossref
Nian Wu & Carmen W. Huie. (1993) Peroxyoxalate chemiluminescence detection in capillary electrophoresis. Journal of Chromatography A 634:2, pages 309-315.
Crossref
Toshimasa Toyo'oka, Mumio Ishibashi & Tadao Terao. (1992) Resolution of carboxylic acid enantiomers by high-performance liquid chromatography with peroxyoxalate chemiluminescence detection. Journal of Chromatography A 627:1-2, pages 75-86.
Crossref
Kazuichi Hayakawa, Noriko Imaizumi & Motoichi Miyazaki. (2005) Effect of a dual‐head short‐stroke pump on post‐column peroxyoxalate chemiluminescence detection. Biomedical Chromatography 5:4, pages 148-152.
Crossref
Sonoko Uzu, Kazuhiro Imai, Kenichiro Nakashima & Shuzo Akiyama. (1991) Use of 4-(N,N-dimethylaminosulphonyl)-7-fluoro-2,1,3-benzoxadiazole as a labelling reagent for peroxyoxalate chemiluminescence detection and its application to the determination of the β-blocker metoprolol in serum by high-performance liquid chromatography. The Analyst 116:12, pages 1353-1357.
Crossref
Peter D. Bryant & Anthony C. Capomacchia. (1991) Use of stop-flow oxalate ester chemiluminescence as a means to determine conditions for high-performance liquid chromatography chemiluminescence detection of retinoids using normal-phase chromatography. Journal of Pharmaceutical and Biomedical Analysis 9:10-12, pages 855-860.
Crossref
Kazuhiro Imai, Atsuhiko Nishitani, Yukie Tsukamoto, Wei‐Hong Wang, Susumu Kanda, Kazuichi Hayakawa & Motoichi Miyazaki. (2005) Studies on the effects of imidazole on the peroxyoxalate chemiluminescence detection system for high performance liquid chromatography. Biomedical Chromatography 4:3, pages 100-104.
Crossref
Nobuaki Hanaoka. (1990) Post-column adjustment of conditions for peroxyoxalate chemiluminescene detection for high-performance liquid chromatography. Journal of Chromatography A 503, pages 155-165.
Crossref
W. Baeyens, J. Bruggeman, C. Dewaele, B. Lin & K. Imai. (2005) Optimization of an HPLC peroxyoxalate chemiluminescence detection system for some dansyl amino acids. Journal of Bioluminescence and Chemiluminescence 5:1, pages 13-23.
Crossref
K. Imai, A. Nishitani, H. Akitomo & Y. Tsukamoto. (2005) Chemiluminescence in HPLC. Journal of Bioluminescence and Chemiluminescence 4:1, pages 500-504.
Crossref
C. Gooijer, N.H. Velthorst & R.W. Frei. 1989. Selective Sample Handling and Detection in High-Performance Liquid Chromatography. Selective Sample Handling and Detection in High-Performance Liquid Chromatography 260 334 .
R.N. Jennings & Anthony C. Capomacchia. (1989) Pre-Chemiluminescent biexponential degradation of bis(2,4-dinitrophenyl) oxalate in hydrogen peroxide-acetonitrile. Analytica Chimica Acta 227, pages 37-48.
Crossref
O.M. Steijger, H.M. van Mastbergen & J.J.M. Holthuis. (1989) Chemiluminescence of bis(2,4,6-trichlorophenyl) oxalate in aqueous micellar systems. Analytica Chimica Acta 217, pages 229-237.
Crossref
U. A. Th. Brinkman, G. J. de Jong & C. Gooijer. 1988. Bioanalysis of Drugs and Metabolites, Especially Anti-Inflammatory and Cardiovascular. Bioanalysis of Drugs and Metabolites, Especially Anti-Inflammatory and Cardiovascular 321 338 .
K. Imai, A. Nishitani & Y. Tsukamoto. (1987) Prediction of the detection ranges for HPLC-peroxyoxalate chemiluminescence detection system of fluorescent compounds. Chromatographia 24:1, pages 77-81.
Crossref
Kazuhiro Imai, Yoriko Matsunaga, Yukie Tsukamoto & Atsuhiko Nishitani. (1987) Application of bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)-phenyl] oxalate to post-column chemiluminescence detection in high-performance liquid chromatography. Journal of Chromatography A 400, pages 169-176.
Crossref
. 1987. High Performance Liquid Chromatography. High Performance Liquid Chromatography 317 344 .
G.J. De Jong*N. Lammers, F.J. Spruit, R.W. Frei & U.A.Th. Brinkman. (1986) Analytical implications of the half-life of the chemiluminescence signal in the peroxyoxalate detection system for liquid chromatography. Journal of Chromatography A 353, pages 249-257.
Crossref
Kimitoshi Miyaguchi, Kazumasa Honda, Toshimasa Toyo'oka & Kazuhiro Imai. (1986) Application of a microbore high-performance liquid chromatography—chemiluminescence detection system to the N-terminal amino acid analysis of bradykinin. Journal of Chromatography A 352, pages 255-260.
Crossref
Kazuhiro Imai. 1986. Bioluminescence and Chemiluminescence Part B. Bioluminescence and Chemiluminescence Part B 435 449 .
Kazuhiro Imai & Robert Weinberger. (1985) Aryl oxalate chemiluminescence detection for high-performance liquid chromatography. TrAC Trends in Analytical Chemistry 4:7, pages 170-175.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.