12
Views
31
CrossRef citations to date
0
Altmetric
Electrodes/Biosensors

Electrochemical Determination of Cholinesterase Activity and Indication of Its Inhibitors Using A Thick-Film Metallized Platinum Electrode

, , &
Pages 1159-1169 | Received 19 Jan 1989, Accepted 24 Jan 1989, Published online: 23 Oct 2006

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (4)

A.L. Simonian, E.I. Rainina & J.R. Wild. (1997) A New Approach For Discriminative Detection of Organophosphate Neurotoxins in the Presence of Other Cholinesterase Inhibitors. Analytical Letters 30:14, pages 2453-2468.
Read now
P. Skládal, M. Fiala & J. Krejcí. (1996) Detection of Pesticides in the Environment Using Biosensors Based on Cholinesterases. International Journal of Environmental Analytical Chemistry 65:1-4, pages 139-148.
Read now
M. Stoytcheva. (1994) Acetylcholinesterase Based Amperometric Sensor. Inhibitor Detection.. Analytical Letters 27:15, pages 3065-3080.
Read now
Petr Skládal, Martin Pavlík & Michal Fiala. (1994) Pesticide Biosensor Based on Coimmobilized Acetylcholinesterase and Butyrylcholinesterase. Analytical Letters 27:1, pages 29-40.
Read now

Articles from other publishers (27)

Flavio Pino, Tribidasari A. Ivandini, Kazuya Nakata, Akira Fujishima, Arben Merkoçi & Yasuaki Einaga. (2015) Magnetic Enzymatic Platform for Organophosphate Pesticide Detection Using Boron-doped Diamond Electrodes. Analytical Sciences 31:10, pages 1061-1068.
Crossref
Madalina-Petruta Bucur, Bogdan Bucur & Gabriel-Lucian Radu. (2013) Critical Evaluation of Acetylthiocholine Iodide and Acetylthiocholine Chloride as Substrates for Amperometric Biosensors Based on Acetylcholinesterase. Sensors 13:2, pages 1603-1613.
Crossref
Barsoum N. Barsoum, Watson M. Watson, Inas M. Mahdi & Elmorsy Khalid. (2004) Electrometric assay for the determination of acetylcholine using a sensitive sensor based on carbon paste. Journal of Electroanalytical Chemistry 567:2, pages 277-281.
Crossref
Maja Snejdarkova, Lenka Svobodova, Dimitrios P. Nikolelis, Joseph Wang & Tibor Hianik. (2003) Acetylcholine Biosensor Based on Dendrimer Layers for Pesticides Detection. Electroanalysis 15:14, pages 1185-1191.
Crossref
Graziella Turdean, Ionel Catalin Popescu & Liviu Oniciu. (2002) Biocapteurs ampérométriques à cholinestérases pour la détermination des pesticides organophosphorés. Canadian Journal of Chemistry 80:3, pages 315-331.
Crossref
A.L Simonian, E.N Efremenko & J.R Wild. (2001) Discriminative detection of neurotoxins in multi-component samples. Analytica Chimica Acta 444:2, pages 179-186.
Crossref
Ruey-An Doong & Hsiao-Chung Tsai. (2001) Immobilization and characterization of sol–gel-encapsulated acetylcholinesterase fiber-optic biosensor. Analytica Chimica Acta 434:2, pages 239-246.
Crossref
P.C. Pandey, S. Upadhyay, H.C. Pathak, C.M.D. Pandey & Ida Tiwari. (2000) Acetylthiocholine/acetylcholine and thiocholine/choline electrochemical biosensors/sensors based on an organically modified sol–gel glass enzyme reactor and graphite paste electrode. Sensors and Actuators B: Chemical 62:2, pages 109-116.
Crossref
Melissa Espinosa, Plamen Atanasov & Ebtisam Wilkins. (1999) Development of a Disposable Organophosphate Biosensor. Electroanalysis 11:14, pages 1055-1062.
Crossref
G.A Evtugyn, A.N Ivanov, E.V Gogol, J.-L Marty & H.C Budnikov. (1999) Amperometric flow-through biosensor for the determination of cholinesterase inhibitors. Analytica Chimica Acta 385:1-3, pages 13-21.
Crossref
Margarita Stoytcheva, Vencislava Sharkova & Jean-Pierre Magnin. (1998) Electrochemical Approach in Studying the Inactivation of Immobilized Acetylcholinesterase by Arsenate(III). Electroanalysis 10:14, pages 994-998.
Crossref
M Stoytcheva, V Sharkova & M Panayotova. (1998) Electrochemical approach in studying the inhibition of acetylcholinesterase by arsenate(III): analytical characterisation and application for arsenic determination. Analytica Chimica Acta 364:1-3, pages 195-201.
Crossref
J.-M. Chemnitius, K.-H. Haselmeyer, B.D. Gonska, H. Kreuzer & R. Zech. (1997) Mipafox differential inhibition assay for heart muscle cholinesterases: Substrate specificity and inhibition of three isoenzymes by physostigmine and quinidine. General Pharmacology: The Vascular System 28:4, pages 567-575.
Crossref
J. Diehl-Faxon, A.L. Ghindilis, P. Atanasov & E. Wilkins. (1996) Direct electron transfer based tri-enzyme electrode for monitoring of organophosphorus pesticides. Sensors and Actuators B: Chemical 36:1-3, pages 448-457.
Crossref
Margarita Stoytcheva & Roumen Zlatev. (2005) Bioelectrocatalytical studies of the effect of some pharmaceuticals on the acetylcholinesterase activity. Electroanalysis 8:7, pages 676-679.
Crossref
Renbing Shi & Kathrin Stein. (1996) Flow injection analysis of paraoxon with the use of an immobilized acetylcholinesterase reactor. Analytica Chimica Acta 324:1, pages 21-27.
Crossref
C. Cremisini, S. Di Sario, J. Mela, R. Pilloton & G. Palleschi. (1995) Evaluation of the use of free and immobilised acetylcholinesterase for paraoxon detection with an amperometric choline oxidase based biosensor. Analytica Chimica Acta 311:3, pages 273-280.
Crossref
Margarita Stoytcheva. (2005) Acetylcholinesterase‐based amperometric sensor. Electroanalysis 7:6, pages 560-562.
Crossref
Toshihiko Imato & Nobuhiko Ishibashi. (1995) Potentiometric butyrylcholine sensor for organophosphate pesticides. Biosensors and Bioelectronics 10:5, pages 435-441.
Crossref
Alexander Günther & Ursula Bilitewski. (1995) Characterisation of inhibitors of acetylcholinesterase by an automated amperometric flow-injection system. Analytica Chimica Acta 300:1-3, pages 117-125.
Crossref
C. La Rosa, F. Pariente, L. Hernández & E. Lorenzo. (1994) Determination of organophosphorus and carbamic pesticides with an acetylcholinesterase amperometric biosensor using 4-aminophenyl acetate as substrate. Analytica Chimica Acta 295:3, pages 273-282.
Crossref
L. Campanella & M. Tomassetti. 1993. Uses of Immobilized Biological Compounds. Uses of Immobilized Biological Compounds 489 499 .
Petr Skládal. (1992) Detection of organophosphate and carbamate pesticides using disposable biosensors based on chemically modified electrodes and immobilized cholinesterase. Analytica Chimica Acta 269:2, pages 281-287.
Crossref
L. Campanella, R. Cocco & M. Tomassetti. (1992) Determination of compounds with anticholinesterase activity in commercial drugs by a new enzyme sensor. Journal of Pharmaceutical and Biomedical Analysis 10:10-12, pages 741-749.
Crossref
L. Campanella, R. Cocco, M.P. Sammartino & M. Tomassetti. (1992) A new enzyme inhibition sensor for organophosphorus pesticides analysis. Science of The Total Environment 123-124, pages 1-16.
Crossref
R.M. Morelis, P.R. Coulet, A. Simplot, C. Boisson & G. Guibaud. (1991) Rapid and sensitive discriminating determination of acetylcholinesterase activity in amniotic fluid with a choline sensor. Clinica Chimica Acta 203:2-3, pages 295-303.
Crossref
U. Wollenberger, K. Setz, F.W. Scheller, U. Löffler, W. Göpel & R. Gruss. (1991) Biosensors for choline, choline esters and inhibitors of choline esterase. Sensors and Actuators B: Chemical 4:3-4, pages 257-260.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.