27
Views
33
CrossRef citations to date
0
Altmetric
Original Articles

Immunodetection of Herbicide 2,4-Dichlorophenoxyacetic Acid by Field-Effect Transistor-Based Biosensors

, , &
Pages 2983-2995 | Received 15 Jun 1994, Accepted 31 Jul 1994, Published online: 22 Aug 2006

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (5)

Vitalia S. Krikunova, Sergei A. Eremin, David S. Smith & John Landon. (2003) Preliminary Screening Method for Dioxin Contamination Using Polarization Fluoroimmunoassay for Chlorinated Phenoxyacid Pesticides. International Journal of Environmental Analytical Chemistry 83:7-8, pages 585-595.
Read now
C. Raman Suri, Manoj Raje & Grish C. Varshney. (2002) Immunosensors for Pesticide Analysis: Antibody Production and Sensor Development. Critical Reviews in Biotechnology 22:1, pages 15-32.
Read now
SergeiA. Eremin, EugeniaG. Matveeva, Augustina Gómez-Hens & Dolores Pérez-Bendito. (1998) Kinetic Determination of 2,4-Dichlorophenoxyacetic Acid by Stopped-Flow Fluorescence Polarization Immunoassay. International Journal of Environmental Analytical Chemistry 71:2, pages 137-146.
Read now
Yoko Nomura, Hitoshi Muguruma, Kazuyoshi Yano, Akimitsu Kugimiya, Scott McNiven, Kazunori Ikebukuro & Isao Karube. (1998) Selective Recognition of 2,4-Dichlorophenoxyacetic Acid Using a Molecularly Imprinted Polymer. Analytical Letters 31:6, pages 973-980.
Read now
B.B. Dzantiev, A.V. Zherdev, O.G. Romanenko & L.A. Sapegova. (1996) Development and Comparative Study of Different Immunoenzyme Techniques for Pesticides Detection. International Journal of Environmental Analytical Chemistry 65:1-4, pages 95-111.
Read now

Articles from other publishers (28)

T.T.K. Nguyen, T.N. Nguyen, G. Anquetin, S. Reisberg, V. Noël, G. Mattana, J. Touzeau, F. Barbault, M.C. Pham & B. Piro. (2018) Triggering the Electrolyte-Gated Organic Field-Effect Transistor output characteristics through gate functionalization using diazonium chemistry: Application to biodetection of 2,4-dichlorophenoxyacetic acid. Biosensors and Bioelectronics 113, pages 32-38.
Crossref
Yu. V. Plekhanova, Yu. E. Firsova, N. V. Doronina, Yu. A. Trotsenko & A. N. Reshetilov. (2013) Aerobic methylobacteria as the basis for a biosensor for dichloromethane detection. Applied Biochemistry and Microbiology 49:2, pages 188-193.
Crossref
F. Schwägele. (2005) Traceability from a European perspective. Meat Science 71:1, pages 164-173.
Crossref
Iva Navrátilová & Petr Skládal. (2004) The immunosensors for measurement of 2,4-dichlorophenoxyacetic acid based on electrochemical impedance spectroscopy. Bioelectrochemistry 62:1, pages 11-18.
Crossref
Michal Lahav, Andrei B. Kharitonov, Orit Katz, Toyoki Kunitake & Itamar Willner. (2000) Tailored Chemosensors for Chloroaromatic Acids Using Molecular Imprinted TiO 2 Thin Films on Ion-Sensitive Field-Effect Transistors . Analytical Chemistry 73:3, pages 720-723.
Crossref
B.I Kurganov, A.V Lobanov, I.A Borisov & A.N Reshetilov. (2001) Criterion for Hill equation validity for description of biosensor calibration curves. Analytica Chimica Acta 427:1, pages 11-19.
Crossref
Juraj Švitel, Anatoli Dzgoev, Kumaran Ramanathan & Bengt Danielsson. (2000) Surface plasmon resonance based pesticide assay on a renewable biosensing surface using the reversible concanavalin A monosaccharide interaction. Biosensors and Bioelectronics 15:7-8, pages 411-415.
Crossref
I. A. Borisov, A. V. Lobanov, A. N. Reshetilov & B. I. Kurganov. (2000) Quantitative analysis of the calibration dependences for biosensors. Applied Biochemistry and Microbiology 36:3, pages 215-220.
Crossref
María-Pilar Marco & Damià Barceló. 2000. Sample handling and trace analysis of pollutants - Techniques, applications and quality assurance. Sample handling and trace analysis of pollutants - Techniques, applications and quality assurance 1075 1105 .
Rosie B. Wong. 2000. Biosensors and Their Applications. Biosensors and Their Applications 283 298 .
Christophe A. Marquette, Pierre R. Coulet & Loı̈c J. Blum. (1999) Semi-automated membrane based chemiluminescent immunosensor for flow injection analysis of okadaic acid in mussels. Analytica Chimica Acta 398:2-3, pages 173-182.
Crossref
C. Nistor & J. Emnéus. (1999) Bioanalytical tools for monitoring polar pollutants. Waste Management 19:2, pages 147-170.
Crossref
J.M Van Emon, C.L Gerlach & K Bowman. (1998) Bioseparation and bioanalytical techniques in environmental monitoring. Journal of Chromatography B: Biomedical Sciences and Applications 715:1, pages 211-228.
Crossref
Christophe A Marquette & Loı̈c J Blum. (1998) Electrochemiluminescence of luminol for 2,4-D optical immunosensing in a flow injection analysis system. Sensors and Actuators B: Chemical 51:1-3, pages 100-106.
Crossref
Robert Koncki, Agnieszka Owczarek, Wojciech Dzwolak & Stanisław Głąb. (1998) Immunoenzymatic sensitisation of membrane ion-selective electrodes. Sensors and Actuators B: Chemical 47:1-3, pages 246-250.
Crossref
Bengt Danielsson, Anatoli Dzgoev, Michael Mecklenburg & Per-Olof Larsson. 1997. Biosensors for Direct Monitoring of Environmental Pollutants in Field. Biosensors for Direct Monitoring of Environmental Pollutants in Field 57 65 .
E.P. Medyantseva, M.G. Vertlib, M.P. Kutyreva, E.I. Khaldeeva, G.K. Budnikov & S.A. Eremin. (1997) The specific immunochemical detection of 2,4-dichlorophenoxyacetic acid and 2,4,5-trichlorophenoxyacetic acid pesticides by amperometric cholinesterase biosensors. Analytica Chimica Acta 347:1-2, pages 71-78.
Crossref
Jiří Horáček & Petr Skládal. (1997) Improved direct piezoelectric biosensors operating in liquid solution for the competitive label-free immunoassay of 2,4-dichlorophenoxyacetic acid. Analytica Chimica Acta 347:1-2, pages 43-50.
Crossref
A. Dzgoev, M. Mecklenburg, B. Xi, A. Miyabayashi, P.-O. Larsson & B. Danielsson. (1997) Optimization of a charge coupled device imaging enzyme linked immuno sorbent assay and supports for the simultaneous determination of multiple 2,4-D samples. Analytica Chimica Acta 347:1-2, pages 87-93.
Crossref
Petr Skládal. (2005) Advances in electrochemical immunosensors. Electroanalysis 9:10, pages 737-745.
Crossref
Tomáš Kaláb & Petr Skládal. (2005) Disposable multichannel immunosensors for 2,4‐dichlorophenoxyacetic acid using acetylcholinesterase as an enzyme label. Electroanalysis 9:4, pages 293-297.
Crossref
J. Richard Aspland & Marie-Claire Hennion. 1997. Trace Determination of Pesticides and their Degradation Products in Water. Trace Determination of Pesticides and their Degradation Products in Water 429 517 .
María-Pilar Marco & Damià Barceló. (1996) Environmental applications of analytical biosensors. Measurement Science and Technology 7:11, pages 1547-1562.
Crossref
Anatoli Dzgoev, Michael Mecklenburg, Per-Olof Larsson & Bengt Danielsson. (1996) Microformat Imaging ELISA for Pesticide Determination. Analytical Chemistry 68:19, pages 3364-3369.
Crossref
Tautgirdas Ruzgas, Elisabeth Csöregi, Jenny Emnéus, Lo Gorton & György Marko-Varga. (1996) Peroxidase-modified electrodes: Fundamentals and application. Analytica Chimica Acta 330:2-3, pages 123-138.
Crossref
Petr Skládal & Tomáš Kaláb. (1995) A multichannel immunochemical sensor for determination of 2,4-dichlorophenoxyacetic acid. Analytica Chimica Acta 316:1, pages 73-78.
Crossref
Maria-Pilar Marco, Shirley Gee & Bruce D. Hammock. (1995) Immunochemical techniques for environmental analysis I. Immunosensors. TrAC Trends in Analytical Chemistry 14:7, pages 341-350.
Crossref
Kim R. Rogers & Llewellyn R. Williams. (1995) Biosensors for environmental monitoring: a regulatory perspective. TrAC Trends in Analytical Chemistry 14:7, pages 289-294.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.