59
Views
33
CrossRef citations to date
0
Altmetric
Original Articles

Ion-Selective Microchemical Sensors with Reduced Preconditioning Time. Membrane Biostability Studies and Applications in Blood Analysis

, , , , , , & show all
Pages 3039-3063 | Received 15 Jun 1994, Published online: 22 Aug 2006

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

VasileV. Cosofret, Wendi Weirauch Olson , SayedA. M. Marzouk, Miklos Erdosy, TimothyA. Johnson & RichardP. Buck. (1996) Calcium Selective Polymeric Membranes for Microfabricated Sensor Arrays. Analytical Letters 29:5, pages 725-743.
Read now

Articles from other publishers (32)

Polyxeni Damala, Elena Zdrachek, Tara Forrest & Eric Bakker. (2022) Unconditioned Symmetric Solid-Contact Electrodes for Potentiometric Sensing. Analytical Chemistry 94:33, pages 11549-11556.
Crossref
Leandro Julian Mele, Pierpaolo Palestri, Luca Selmi & Muhammad A. Alam. (2022) Modeling Non-Equilibrium Ion-Transport in Ion-Selective-Membrane/Electrolyte Interfaces for Electrochemical Potentiometric Sensors. IEEE Sensors Journal 22:13, pages 12987-12996.
Crossref
Mei-Rong Huang & Xin-Gui Li. (2022) Highly sensing and transducing materials for potentiometric ion sensors with versatile applicability. Progress in Materials Science 125, pages 100885.
Crossref
Yi Heng Cheong, Kaushal Sagar & Grzegorz Lisak. (2021) Evolution of electrochemical potentials mediated by lipophilic salts at the buried membrane interface of solid contact ion selective electrodes. Sensors and Actuators B: Chemical 349, pages 130766.
Crossref
Celeste R. Rousseau & Philippe Bühlmann. (2021) Calibration-free potentiometric sensing with solid-contact ion-selective electrodes. TrAC Trends in Analytical Chemistry 140, pages 116277.
Crossref
Yi Heng Cheong, Liya Ge, Nahong Zhao, Lay Kuan Teh & Grzegorz Lisak. (2020) Ion selective electrodes utilizing a ferrocyanide doped redox active screen-printed solid contact - impact of electrode response to conditioning. Journal of Electroanalytical Chemistry 870, pages 114262.
Crossref
Yuzhou Shao, Yibin Ying & Jianfeng Ping. (2020) Recent advances in solid-contact ion-selective electrodes: functional materials, transduction mechanisms, and development trends. Chemical Society Reviews 49:13, pages 4405-4465.
Crossref
Marwa El badry Mohamed, Fakiha El-Taib Heakal & M. Mohamed Soliman. (2019) Newly selective electrochemical sensors for trace-level determination of Al(III) ions in drainage water, spiked tap water and pharmaceutical preparation samples. Journal of the Iranian Chemical Society 16:12, pages 2795-2807.
Crossref
Matthew T. Flavin, Daniel K. Freeman & Jongyoon Han. (2019) Interfacial ion transfer and current limiting in neutral-carrier ion-selective membranes: A detailed numerical model. Journal of Membrane Science 572, pages 374-381.
Crossref
Marceline Akieh-Pirkanniemi, Grzegorz Lisak, Jesus Arroyo, Johan Bobacka & Ari Ivaska. (2016) Tuned ionophore-based bi-membranes for selective transport of target ions. Journal of Membrane Science 511, pages 76-83.
Crossref
Miao Chen, Yan Jin, Xiaohu Qu, Qinghui Jin & Jianlong Zhao. (2014) Electrochemical impedance spectroscopy study of Ta2O5 based EIOS pH sensors in acid environment. Sensors and Actuators B: Chemical 192, pages 399-405.
Crossref
Ewa Jaworska, Morten Schmidt, Giuseppe Scarpa, Krzysztof Maksymiuk & Agata Michalska. (2014) Spray-coated all-solid-state potentiometric sensors. The Analyst 139:22, pages 6010-6015.
Crossref
Arnaud Emmanuel Musa, Francisco Javier del Campo, Natalia Abramova, María Asunción Alonso‐Lomillo, Olga Domínguez‐Renedo, María Julia Arcos‐Martínez, Monica Brivio, Detlef Snakenborg, Oliver Geschke & Jörg Peter Kutter. (2010) Disposable Miniaturized Screen‐Printed pH and Reference Electrodes for Potentiometric Systems. Electroanalysis 23:1, pages 115-121.
Crossref
Ernö Lindner & Róbert E. Gyurcsányi. (2008) Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes. Journal of Solid State Electrochemistry 13:1, pages 51-68.
Crossref
Ernö Lindner & Yoshio Umezawa. (2008) Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report). Pure and Applied Chemistry 80:1, pages 85-104.
Crossref
Abdelhamid Errachid, Nadia Zine, Josep Samitier & Joan Bausells. (2004) FET‐Based Chemical Sensor Systems Fabricated with Standard Technologies. Electroanalysis 16:22, pages 1843-1851.
Crossref
Hakhyun Nam, Geun Sig Cha, T.D. Strong, Jeonghan Ha, Jun Ho Sim, R.W. Hower, S.M. Martin & R.B. Brown. (2003) Micropotentiometric sensors. Proceedings of the IEEE 91:6, pages 870-880.
Crossref
A Errachid, J Bausells, N Zine, H Jaffrezic, C Martelet, N Jaffrezic-Renault & M Charbonnier. (2002) Analytical features of K+-sensitive membrane obtained by implantation in silicon dioxide films. Materials Science and Engineering: C 21:1-2, pages 9-13.
Crossref
Setsuko Yajima, Yuri Sonoyama, Ken Suzuki & Keiichi Kimura. (2002) Ion-sensor property and blood compatibility of neutral-carrier-type poly(vinyl chloride) membranes coated by phosphorylcholine polymers. Analytica Chimica Acta 463:1, pages 31-37.
Crossref
A Errachid, A Ivorra, J Aguiló, R Villa, N Zine & J Bausells. (2001) New technology for multi-sensor silicon needles for biomedical applications. Sensors and Actuators B: Chemical 78:1-3, pages 279-284.
Crossref
Jae Ho Shin, Jae Seon Lee, Sung Hyuk Choi, Dong Kwon Lee, Hakhyun Nam & Geun Sig Cha. (2000) A Planar pCO 2 Sensor with Enhanced Electrochemical Properties . Analytical Chemistry 72:18, pages 4468-4473.
Crossref
P. Lemoine, P. Mailley, M. Hyland, J.M. McLaughlin, E. McAdams, J. Anderson, A. Lynch, D. Diamond & M. Leader. (2000) Swelling and delamination of multi-electrode sensor arrays studied by variable-pressure scanning electron microscopy. Journal of Biomedical Materials Research 50:3, pages 313-321.
Crossref
Andrey Bratov, Natalia Abramova, Carlos Domı́nguez & Antonio Baldi. (2000) Ion-selective field effect transistor (ISFET)-based calcium ion sensor with photocured polyurethane membrane suitable for ionised calcium determination in milk. Analytica Chimica Acta 408:1-2, pages 57-64.
Crossref
D.J. Harrison, M. Rothmaier & Zhong Li. (1997) Isolation and identification of drift sources in planar ion sensors during initial water uptake: correlation of model and experiment. Isolation and identification of drift sources in planar ion sensors during initial water uptake: correlation of model and experiment.
J. Muñoz, C. Jimenez, A. Bratov, J. Bartroli, S. Alegret & C. Dominguez. (1997) Photosensitive polyurethanes applied to the development of CHEMFET and ENFET devices for biomedical sensing. Biosensors and Bioelectronics 12:7, pages 577-585.
Crossref
C.J Somps, J.L Pickering, M.J Madou, J.W Hines, D.L Gibbs & M.R Harrison. (1996) Electrochemical performance of an ion selective, polymeric membrane following chronic implantation in rat subcutaneous tissue. Sensors and Actuators B: Chemical 35:1-3, pages 222-227.
Crossref
Kelly A. Brooks, John R. Allen, Pamela W. Feldhoff & Leonidas G. Bachas. (1996) Effect of Surface-Attached Heparin on the Response of Potassium-Selective Electrodes. Analytical Chemistry 68:8, pages 1439-1443.
Crossref
Zhong Li, Xizhong Li, Markus Rothmaier & D. Jed Harrison. (1996) Comparison of Numerical Modeling of Water Uptake in Poly(vinyl chloride)-Based Ion-Selective Membranes with Experiment. Analytical Chemistry 68:10, pages 1726-1734.
Crossref
Zhong Li, Xizhong Li, Slobodan Petrović & D. Jed Harrison. (1996) Dual-Sorption Model of Water Uptake in Poly(vinyl chloride)-Based Ion-Selective Membranes:  Experimental Water Concentration and Transport Parameters. Analytical Chemistry 68:10, pages 1717-1725.
Crossref
Vasile V. Cosofret, Miklos Erdosy, Timothy A. Johnson, Dwight A. Bellinger, Richard P. Buck, R.Bruce Ash & Michael R. Neuman. (1995) Electroanalytical and surface characterization of encapsulated implantable membrane planar microsensors. Analytica Chimica Acta 314:1-2, pages 1-11.
Crossref
Ernô Lindner, Vasile V. Cosofret, Richard P. Buck, Timothy A. Johnson, R. Bruce Ash, Michael R. Neuman, Weiyuan J. Kao & James M. Anderson. (2005) Electroanalytical and biocompatibility studies on microfabricated array sensors. Electroanalysis 7:9, pages 864-870.
Crossref
Richard P. Buck, Vasile V. Cosofret, Erno Lindner, Stefan Ufer, Marcel B. Mudaras, Timothy A. Johnson, R. Bruce Ash & Michael R. Neumun. (2005) Microfabrication technology of flexible membrane based sensors for in vivo applications. Electroanalysis 7:9, pages 846-851.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.