593
Views
16
CrossRef citations to date
0
Altmetric
Original Article

Development of a phantom compatible for MRI and hyperthermia using carrageenan gel—relationship between dielectric properties and NaCl concentration

, , , , , , , , , & show all
Pages 529-538 | Received 05 Sep 2003, Accepted 05 Jan 2004, Published online: 09 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Ali Dabbagh, Basri Johan Jeet Abdullah, Noor Hayaty Abu Kasim & Chanthiriga Ramasindarum. (2014) Reusable heat-sensitive phantom for precise estimation of thermal profile in hyperthermia application. International Journal of Hyperthermia 30:1, pages 66-74.
Read now

Articles from other publishers (15)

Matteo B. Lodi, Antonios Makridis, Konstantina Kazeli, Theodoros Samaras, Makis Angelakeris, Giuseppe Mazzarella & Alessandro Fanti. (2024) On the Evaluation of the Hyperthermic Efficiency of Magnetic Scaffolds. IEEE Open Journal of Engineering in Medicine and Biology 5, pages 88-98.
Crossref
Xinyu Zhong, Yuting Cao & Ping Zhou. (2022) Thermochromic Tissue-Mimicking Phantoms for Thermal Ablation Based on Polyacrylamide Gel. Ultrasound in Medicine & Biology 48:8, pages 1361-1372.
Crossref
Matteo Bruno Lodi, Antonis Makridis, Nicola M. Carboni, Konstantina Kazeli, Nicola Curreli, Theodoros Samaras, Makis Angelakeris, Giuseppe Mazzarella & Alessandro Fanti. (2022) Design and Characterization of Magnetic Scaffolds for Bone Tumor Hyperthermia. IEEE Access 10, pages 19768-19779.
Crossref
Jiahao Lin, Siyuan Liu, Marvin Bergsneider, J. Rock Hadley, Giyarpuram N. Prashant, Sophie Peeters, Robert N. Candler & Kyunghyun Sung. (2022) A Miniature Flexible Coil for High-SNR MRI of the Pituitary Gland. IEEE Access 10, pages 12619-12628.
Crossref
Michael Woletz, Sigrun Roat, Allan Hummer, Martin Tik & Christian Windischberger. (2021) Technical Note: Human tissue‐equivalent MRI phantom preparation for 3 and 7 Tesla. Medical Physics 48:8, pages 4387-4394.
Crossref
Dinil Sasi S, Anandh K. Ramaniharan, Rupsa Bhattacharjee, Rakesh K. Gupta, Indrajit Saha, Marc Van Cauteren, Tejas Shah, Karthik Gopalakrishnan, Abhinav Gupta & Anup Singh. (2020) Evaluating feasibility of high resolution T1-perfusion MRI with whole brain coverage using compressed SENSE: Application to glioma grading. European Journal of Radiology 129, pages 109049.
Crossref
Y. De Deene. 2020. NMR and MRI of Gels. NMR and MRI of Gels 358 378 .
Bibin Prasad, Jung Kyung Kim & Suzy Kim. (2019) Role of Simulations in the Treatment Planning of Radiofrequency Hyperthermia Therapy in Clinics. Journal of Oncology 2019, pages 1-12.
Crossref
Jean-David Jutras, Keith Wachowicz, Guillaume Gilbert & Nicola De Zanche. (2017) SNR efficiency of combined bipolar gradient echoes: Comparison of three-dimensional FLASH, MPRAGE, and multiparameter mapping with VFA-FLASH and MP2RAGE. Magnetic Resonance in Medicine 77:6, pages 2186-2202.
Crossref
Ali Dabbagh, Basri Johan Jeet Abdullah, Chanthiriga Ramasindarum & Noor Hayaty Abu Kasim. (2014) Tissue-Mimicking Gel Phantoms for Thermal Therapy Studies. Ultrasonic Imaging 36:4, pages 291-316.
Crossref
Kengo Hattori, Yusuke Ikemoto, Wataru Takao, Seiichiro Ohno, Takashi Harimoto, Susumu Kanazawa, Masataka Oita, Koichi Shibuya, Masahiro Kuroda & Hirokazu Kato. (2013) Development of MRI phantom equivalent to human tissues for 3.0‐T MRI. Medical Physics 40:3.
Crossref
Yu Yuan, Cory Wyatt, Paolo Maccarini, Paul Stauffer, Oana Craciunescu, James MacFall, Mark Dewhirst & Shiva K Das. (2012) A heterogeneous human tissue mimicking phantom for RF heating and MRI thermal monitoring verification. Physics in Medicine and Biology 57:7, pages 2021-2037.
Crossref
Yusuke Ikemoto, Wataru Takao, Keisuke Yoshitomi, Seiichiro Ohno, Takashi Harimoto, Susumu Kanazawa, Koichi Shibuya, Masahiro Kuroda & Hirokazu Kato. (2011) Development of a human‐tissue‐like phantom for 3.0‐T MRI. Medical Physics 38:11, pages 6336-6342.
Crossref
Seiichiro OHNO, Hirokazu KATO, Takashi HARIMOTO, Yusuke IKEMOTO, Keisuke YOSHITOMI, Sigefumi KADOHISA, Masahiro KURODA & Susumu KANAZAWA. (2008) Production of a Human-Tissue-Equivalent MRI Phantom: Optimization of Material Heating. Magnetic Resonance in Medical Sciences 7:3, pages 131-140.
Crossref
Hirokazu Kato, Masahiro Kuroda, Koichi Yoshimura, Atsushi Yoshida, Katsumi Hanamoto, Shoji Kawasaki, Koichi Shibuya & Susumu Kanazawa. (2005) Composition of MRI phantom equivalent to human tissues. Medical Physics 32:10, pages 3199-3208.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.