2,235
Views
18
CrossRef citations to date
0
Altmetric
Articles

The effects of manufacturing tolerances and assembly force on the volumetric wear at the taper junction in modular total hip arthroplasty

, , , , &
Pages 1061-1072 | Received 26 Feb 2019, Accepted 01 Jun 2019, Published online: 17 Jun 2019

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Guoxian Zhang, Shu Yang, Wen Cui, Zhi Huang, Xiaogang Zhang, Yali Zhang, Junyan Li & Zhongmin Jin. (2023) Decomposition of micromotion at the head-neck interface in total hip arthroplasty during walking. Computer Methods in Biomechanics and Biomedical Engineering 26:5, pages 548-558.
Read now

Articles from other publishers (17)

Md Mohiuddin Soliman, Mohammad Tariqul Islam, Muhammad E. H. Chowdhury, Abdulrahman Alqahtani, Farayi Musharavati, Touhidul Alam, Ahmed S. Alshammari, Norbahiah Misran, Mohamed S. Soliman, Sakib Mahmud & Amith Khandakar. (2023) Advancement in total hip implant: a comprehensive review of mechanics and performance parameters across diverse novelties. Journal of Materials Chemistry B 11:44, pages 10507-10537.
Crossref
Jessica Osan, Moreica Pabbruwe, Alan Kop, Alex Joyce, Phil Vlaskovsky, Mobin Salasi & Markus Kuster. (2022) The effect of trunnionosis on the risk of re-revision following femoral head exchange in hip arthroplasty. HIP International 33:6, pages 1072-1078.
Crossref
Jian Pu, Yali Zhang, Xiaogang Zhang, Xiaoyu Zhang, Xinlu Yuan, Zhongyi Wang, Guoxian Zhang, Wen Cui & Zhongmin Jin. (2023) Revealing the composite fretting-corrosion mechanisms of Ti6Al4V alloy against zirconia-toughened alumina ceramic in simulated body fluid. Journal of the Mechanical Behavior of Biomedical Materials 146, pages 106074.
Crossref
Guoxian Zhang, Wen Cui, Xing Peng, Jian Pu, Junyan Li & Zhongmin Jin. (2023) Effect of angular mismatch on tribocorrosion at taper-trunnion junction using a finite element model considering mechanical and chemical wear. Tribology International 184, pages 108477.
Crossref
Md Mohiuddin Soliman, Muhammad E. H. Chowdhury, Mohammad Tariqul Islam, Farayi Musharavati, Sakib Mahmud, Muhammad Hafizh, Mohamed Arselene Ayari, Amith Khandakar, Mohammad Kaosar Alam & Erfan Zal Nezhad. (2023) Design and Performance Evaluation of a Novel Spiral Head-Stem Trunnion for Hip Implants Using Finite Element Analysis. Materials 16:4, pages 1466.
Crossref
Jonathan A. Gustafson, Steven P. Mell, Brett R. Levine, Robin Pourzal & Hannah J. Lundberg. (2022) Interaction of surface topography and taper mismatch on head‐stem modular junction contact mechanics during assembly in modern total hip replacement. Journal of Orthopaedic Research 41:2, pages 418-425.
Crossref
Andrea Martelli, Paolo Erani, Nicola Pazzagli, Valeria Cannillo & Massimiliano Baleani. (2023) Surface Analysis of Ti-Alloy Micro-Grooved 12/14 Tapers Assembled to Non-Sleeved and Sleeved Ceramic Heads: A Comparative Study of Retrieved Hip Prostheses. Materials 16:3, pages 1067.
Crossref
Christian M Wight & Emil H Schemitsch. (2022) In vitro testing for hip head-neck taper tribocorrosion: A review of experimental methods. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 236:4, pages 469-482.
Crossref
Khosro Fallahnezhad, Mohsen Feyzi, Khashayar Ghadirinejad, Reza Hashemi & Mark Taylor. (2022) Finite element based simulation of tribocorrosion at the head-neck junction of hip implants. Tribology International 165, pages 107284.
Crossref
Berend Denkena, Christof Hurschler, Benjamin Bergmann, Beate Legutko, Marco Gustav & Bastian Welke. (2022) Influence of surface topography on junction strength of modular hip endoprostheses. Procedia CIRP 110, pages 64-69.
Crossref
Xianyuan Meng, Lihua Chen, Lutong Shan & Hui Liu. (2021) Simulation of Fretting Wear on the Contact Surface between Cortical Bone and Titanium Alloy. Simulation of Fretting Wear on the Contact Surface between Cortical Bone and Titanium Alloy.
Paul Dobria, Arpan Patel & Brett Levine. (2021) Catastrophic intraoperative failure of a ceramic femoral head. Arthroplasty Today 11, pages 234-238.
Crossref
K.N. Chethan, N. Shyamasunder Bhat, Mohammad Zuber & B Satish Shenoy. (2021) Finite element analysis of hip implant with varying in taper neck lengths under static loading conditions. Computer Methods and Programs in Biomedicine 208, pages 106273.
Crossref
Mohsen Feyzi, Khosro Fallahnezhad, Mark Taylor & Reza Hashemi. (2021) The mechanics of head-neck taper junctions: What do we know from finite element analysis?. Journal of the Mechanical Behavior of Biomedical Materials 116, pages 104338.
Crossref
Mohsen Feyzi, Khosro Fallahnezhad, Mark Taylor & Reza Hashemi. (2021) A review on the finite element simulation of fretting wear and corrosion in the taper junction of hip replacement implants. Computers in Biology and Medicine 130, pages 104196.
Crossref
A. Wade, A.R. Beadling, A. Neville, D. De Villiers, C.J. Cullum, S. Collins & M.G. Bryant. (2020) Geometric Variations of Modular Head-Stem Taper Junctions of Total Hip Replacements. Medical Engineering & Physics 83, pages 34-47.
Crossref
Jonathan A. Gustafson, Robin Pourzal, Brett R. Levine, Joshua J. Jacobs & Hannah J. Lundberg. (2020) Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty. The Bone & Joint Journal 102-B:7_Supple_B, pages 33-40.
Crossref