200
Views
27
CrossRef citations to date
0
Altmetric
Original Articles

Highly Crosslinked Polyethylenes in Hip Replacements: Improved Wear Performance or Paradox?

, , , &
Pages 277-290 | Received 16 Dec 2006, Accepted 08 Mar 2007, Published online: 25 Mar 2008

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (4)

Matúš Ranuša, Jiří Gallo, Martin Vrbka, Martin Hobza, David Paloušek, Ivan Křupka & Martin Hartl. (2017) Wear Analysis of Extracted Polyethylene Acetabular Cups Using a 3D Optical Scanner. Tribology Transactions 60:3, pages 437-447.
Read now
Jian Chen, Ben D. Beake, Gerard A. Bell, Yalan Tait & Fengge Gao. (2015) Probing polymer chain constraint and synergistic effects in nylon 6-clay nanocomposites and nylon 6-silica flake sub-micro composites with nanomechanics. Nanocomposites 1:4, pages 185-194.
Read now
B. D. Beake, G. A. Bell, S. R. Goodes, N. J. Pickford & J. F. Smith. (2010) Improved nanomechanical test techniques for surface engineered materials. Surface Engineering 26:1-2, pages 37-49.
Read now

Articles from other publishers (23)

Shuo Li, Peirou Chen, Dewen Zhou, Mengqi Hou, Shanke Wan, Qian Cheng & Dongtao Yu. (2022) Characterization of shape memory silane cross‐linked low‐density polyethylene prepared by solid‐phase grafting process. Journal of Applied Polymer Science 139:23.
Crossref
Alessandro Ruggiero, Alessandro Sicilia & Saverio Affatato. (2020) In silico total hip replacement wear testing in the framework of ISO 14242-3 accounting for mixed elasto-hydrodynamic lubrication effects. Wear 460-461, pages 203420.
Crossref
A.P. Harsha, Rolf Wäsche & Thomas J. Joyce. (2019) Wear of Biopolymers under Reciprocating Sliding Conditions against Different Counterfaces. Polymer Engineering & Science 59:11, pages 2356-2366.
Crossref
Saverio Affatato, Jonathan Salvatore De Mattia, Pierangiola Bracco, Eleonora Pavoni & Paola Taddei. (2016) Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test. Journal of the Mechanical Behavior of Biomedical Materials 64, pages 240-252.
Crossref
Hiroyuki OhshimaAtsushi Suzuki & Teruo Murakami. 2016. Encyclopedia of Biocolloid and Biointerface Science 2V Set. Encyclopedia of Biocolloid and Biointerface Science 2V Set 269 270 .
Chau-Chang Chou, Yang-Zhi Wang, Jyun-Hao You & Cheng-Lun Wu. (2015) Tribological and oxidational properties of porous high-pressure crystallized and vitamin E–incorporated ultra-high-molecular weight polyethylene as an artificial cartilage. Advances in Mechanical Engineering 7:7, pages 168781401559388.
Crossref
Teruo Murakami, Seido Yarimitsu, Kazuhiro Nakashima, Tetsuo Yamaguchi, Yoshinori Sawae, Nobuo Sakai & Atsushi Suzuki. (2014) Superior lubricity in articular cartilage and artificial hydrogel cartilage. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology 228:10, pages 1099-1111.
Crossref
Ryan M. Baxter, Daniel W. MacDonald, Steven M. Kurtz & Marla J. Steinbeck. (2013) Severe Impingement of Lumbar Disc Replacements Increases the Functional Biological Activity of Polyethylene Wear Debris. Journal of Bone and Joint Surgery 95:11, pages e75.
Crossref
A.P. Harsha & Tom J Joyce. (2013) Comparative wear tests of ultra-high molecular weight polyethylene and cross-linked polyethylene. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 227:5, pages 600-608.
Crossref
K.G. Plumlee & C.J. Schwartz. (2013) Surface layer plastic deformation as a mechanism for UHMWPE wear, and its role in debris size.. Wear 301:1-2, pages 257-263.
Crossref
Ran Schwarzkopf, Fabio M. Sagebin, Raj Karia, Karl M. Koenig, Joseph A. Bosco & James D. Slover. (2013) Factors Influencing Patients’ Willingness to Pay for New Technologies in Hip and Knee Implants. The Journal of Arthroplasty 28:3, pages 390-394.
Crossref
C. Cho, T. Murakami & Y. Sawae. 2013. Wear of Orthopaedic Implants and Artificial Joints. Wear of Orthopaedic Implants and Artificial Joints 221 245 .
Ryan M. Baxter, Daniel W. MacDonald, Steven M. Kurtz & Marla J. Steinbeck. (2013) Characteristics of highly cross-linked polyethylene wear debris in vivo . Journal of Biomedical Materials Research Part B: Applied Biomaterials, pages n/a-n/a.
Crossref
Teruo Murakami. (2012) Importance of adaptive multimode lubrication mechanism in natural and artificial joints. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology 226:10, pages 827-837.
Crossref
Saverio Affatato, Pierangiola Bracco, Luigi Costa, Tomaso Villa, Virginio Quaglini & Aldo Toni. (2012) In vitro wear performance of standard, crosslinked, and vitamin-E-blended UHMWPE. Journal of Biomedical Materials Research Part A 100A:3, pages 554-560.
Crossref
Victoria K. Maskiewicz, Paul A. Williams, Sarah J. Prates, John G. Bowsher & Ian C. Clarke. (2010) Characterization of protein degradation in serum‐based lubricants during simulation wear testing of metal‐on‐metal hip prostheses. Journal of Biomedical Materials Research Part B: Applied Biomaterials 94B:2, pages 429-440.
Crossref
Paul A. Williams, Cindy M. Brown, Riichro Tsukamoto & Ian C. Clarke. (2009) Polyethylene wear debris produced in a knee simulator model: Effect of crosslinking and counterface material. Journal of Biomedical Materials Research Part B: Applied Biomaterials 92B:1, pages 78-85.
Crossref
Hélène Libouban, Philippe Massin, Christine Gaudin, Philippe Mercier, Michel F. Baslé & Daniel Chappard. (2009) Migration of wear debris of polyethylene depends on bone microarchitecture. Journal of Biomedical Materials Research Part B: Applied Biomaterials 90B:2, pages 730-737.
Crossref
T Sorimachi, I C Clarke, P A Williams, A Gustafson & K Yamamoto. (2009) Third-body abrasive wear challenge of 32 mm conventional and 44 mm highly crosslinked polyethylene liners in a hip simulator model. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 223:5, pages 607-623.
Crossref
K. Kubo, I.C. Clarke, T. Sorimachi, P.A. Williams, T.K. Donaldson & K. Yamamoto. (2009) Aggressive 3rd-body wear challenge to highly crosslinked polyethylene: A hip simulator model. Wear 267:5-8, pages 734-742.
Crossref
P.A. Williams & I.C. Clarke. (2009) Understanding polyethylene wear mechanisms by modeling of debris size distributions. Wear 267:1-4, pages 646-652.
Crossref
J. G. Bowsher, P. A. Williams, I. C. Clarke, D. D. Green & T. K. Donaldson. (2008) “Severe” wear challenge to 36 mm mechanically enhanced highly crosslinked polyethylene hip liners. Journal of Biomedical Materials Research Part B: Applied Biomaterials 86B:1, pages 253-263.
Crossref
Riichiro Tsukamoto, Paul Allen Williams, Hiromu Shoji, Kazuo Hirakawa, Kengo Yamamoto, Mikiko Tsukamoto & Ian C. Clarke. (2008) Wear in molded tibial inserts: Knee simulator study of H1900 and GUR1050 polyethylenes. Journal of Biomedical Materials Research Part B: Applied Biomaterials 85B:2, pages 314-319.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.